Vixel Model 335 Installation & Configuration Guide | APPENDIX C Event Messages | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Ref | Event | Meaning |
| Action | Severity |
|
| Message |
|
| ||||
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| 203 | Port switch connect | A number of stalls have |
| Info |
| |
|
| overflow | occurred in a specific amount |
|
|
| |
|
|
| of time. |
|
|
|
|
|
|
|
|
|
|
| |
| 204 | Port switch stall | An instance occurred where | Info |
| ||
|
|
| two devices could not discon- |
|
|
| |
|
|
| nect communications with one |
|
|
| |
|
|
| another. |
|
|
|
|
| 205 | Port switch bad | A device is trying to send an | Info |
| ||
|
| open | OPN but it cannot be delivered. |
|
|
| |
|
|
|
|
|
|
| |
| 206 | Port clock delta freq | The switch clock or a device | Info |
| ||
|
| error | clock are not synchronized. If |
|
|
| |
|
|
| the switch clock has failed, the |
|
|
| |
|
|
| error should display on multi- |
|
|
| |
|
|
| ple ports. If only one port is |
|
|
| |
|
|
| logging this error, it is most |
|
|
| |
|
|
| likely a problem with that |
|
|
|
|
|
|
| device. |
|
|
|
|
| 207 | Port clock delta freq | The switch clock and a device | Info |
| ||
|
| ok | are synchronized. |
|
|
|
|
|
|
|
|
|
|
|
|
| 208 | Bad zone detected | Refers to the zone health. |
| Info |
| |
| 209 | Cascade user mode | A user setting for cascades has | Info |
| ||
|
| overridden | been overridden by the firm- |
|
|
| |
|
|
| ware. |
|
|
|
|
|
|
|
|
|
|
| |
| 210 | Console password | The command line interface | Notice |
| ||
|
| changed | password was changed. Note: |
|
|
| |
|
|
| The password cannot be |
|
|
|
|
|
|
| changed without supplying the |
|
|
| |
|
|
| current password, even if |
|
|
|
|
|
|
| logged on. |
|
|
|
|
| 241 | Port bypassed | A port was bypassed manually, | Info |
| ||
|
| (external loopback) | through either the command |
|
|
| |
|
|
| line interface or a management |
|
|
| |
|
|
| entity. |
|
|
|
|
|
|
|
|
|
|
| |
| 242 | Port bypassed | A port was bypassed manually, | Info |
| ||
|
| (diagnostic TX) | through either the command |
|
|
| |
|
|
| line interface or a management |
|
|
| |
|
|
| entity. |
|
|
|
|
| 243 | Port bypassed (Loss | Although a transceiver is |
| Info |
| |
|
| of RX signal) | present, the port is bypassed |
|
|
| |
|
|
| because there is no signal com- |
|
|
| |
|
|
| ing into the port. |
|
|
|
|
|
|
|
|
|
|
|
|
| 244 | Port bypassed (Loss | Although a transceiver is |
| Info |
| |
|
| of Sync) | present, the port is bypassed |
|
|
| |
|
|
| because the port lost sync with |
|
|
| |
|
|
| the fibre channel signal (no |
|
|
| |
|
|
| command characters were |
|
|
|
|
|
|
| received). |
|
|
|
|
| 250 | Port transmitter | A port transmitter was turned | Notice |
| ||
|
| enabled | on, through either the com- |
|
|
| |
|
|
| mand line interface or a man- |
|
|
| |
|
|
| agement entity. |
|
|
|
|
|
|
|
|
|
|
| |
| 251 | Port transmitter | A port transmitter was turned | Notice |
| ||
|
| disabled | off, through either the com- |
|
|
| |
|
|
| mand line interface or a man- |
|
|
| |
|
|
| agement entity. |
|
|
|
|
| 260 | Key feature enabled | A purchased license key for an | Info |
| ||
|
|
| optional feature was entered, |
|
|
| |
|
|
| through either the command |
|
|
| |
|
|
| line interface or a management |
|
|
| |
|
|
| entity. |
|
|
|
|
|
|
|
|
|
|
| |
| 261 | Key feature disabled | An optional feature was dis- | Notice |
| ||
|
|
| abled, through either the com- |
|
|
| |
|
|
| mand line interface or a |
|
|
|
|
|
|
| management entity. |
|
|
|
|
| 270 | Daytime server up | The daytime server is running. | Info |
| ||
|
|
|
|
|
|
| |
| 271 | Daytime server | The daytime server is not run- | Notice |
| ||
|
| down | ning. |
|
|
|
|
|
|
|
|
|
|
|
|
65