Desa V3610ST manual Flashing Installation, Terminations, Storm Collar Installation

Page 12

12

FINISHING YOUR CHIMNEY SYSTEM

Flashing Installation

Storm Collar Installation

Terminations

VENTING INSTALLTION

Continued

Flashing Installation

Determine the flashing to be used with the roof opening chart, page

11.Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles. DO NOT NAIL

THROUGH FLASHING CONE.

Storm Collar

 

 

Chimney Pipe

Flashing

Overlap

 

Nail Only Outer

Shingles

Top and

Perimeter of

Sides

Flashing

Only

 

Terminations

The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the terminations.

The terminations approved for this fireplace are RTL-10DM, which can be used for flashing, or chase and ETL-10DM for chase style termination only. Figure 28 shows an RTL-10DM round top termination.

CAUTION: Do not seal openings on the rooftop flashing. Follow the installation instructions pro- vided with the termination being used.

Underlap Shingles

At Bottom

Figure 26 - Flashing Installation

Storm Collar Installation

Place storm collar over pipe and slide down until snug against the open edge of the flashing (see Figures 26 and 27). Apply waterproof caulking to all seams and notches around storm collar and also at base around shingles.

Chimney Pipe

Caulk

Stainless

Inner Flue

Pipe

Secure

Termination

To Outer

Pipe With

3 Screws

Overlap Shingles

(Top and Sides)

of Flashing Base

RTL-10DM

1" Noncombustible

Spacer

Chase Top

Screen

1" Space

Apply Waterproof

Caulking

Storm Collar

Flashing

Underlap

Shingles

Storm Collar

Flashing

Figure 27 - Storm Collar

Figure 28 - Terminations

For morevisit www..com

55253C

Image 12
Contents For Your Safety SavannahSave this Book Table of Contents Product DimensionsSafety Information IntroductionBefore YOU Begin Fireplace Installation Selecting LocationClearances Mantle ClearancesFraming MINHearth Extensions 7cmOutside AIR KIT Installation GAS Line InstallationGAS Line Installation Venting Installtion Pipe InstallationChimney Pipe Installation Firestop SpacersElbow Offset Installation Support SectionsFinishing Your Chimney System Foot RuleMinimum Chimney Height Maximum Chimney HeightChimney Maintenance Roof Opening ChartFlashing Installation Storm Collar InstallationTerminations Installing Fireplace Facing Chase InstallationOperating Guidelines and Maintenance Instructions Cleaning the GlassGlass Doors Technical Service Damper MechanismOutside AIR Mechanism GrateReplacement and Accessory Parts 18/12 to 24/12Owners Registration Form Postage Required 55253C Not a UPC

V3610ST specifications

The Desa V3610ST is an innovative solution designed to meet the heating needs of residential and commercial spaces. Renowned for its reliability and efficiency, this model stands out in the market with several noteworthy features and technologies.

At the heart of the Desa V3610ST lies its advanced heating technology. It utilizes a powerful yet energy-efficient propane gas system, delivering a maximum output of 30,000 BTUs. This ensures effective heating for medium-sized rooms, providing comfort during the cold months. The integrated thermostat allows for precise temperature control, enabling users to set their desired ambiance easily and efficiently.

One of the standout characteristics of the V3610ST is its sleek and modern design. The unit is finished in a stylish black or white, which allows it to blend seamlessly with various interior décors. Its compact size ensures that it doesn't take up excessive space, making it ideal for smaller rooms or apartments.

Another significant aspect of the Desa V3610ST is its user-friendly interface. The control panel is intuitive, allowing users to adjust settings effortlessly. The easy-to-read display gives real-time feedback on temperature settings, operating modes, and system diagnostics, ensuring optimal performance and ease of use.

The V3610ST also places a strong emphasis on safety. It comes equipped with advanced safety features such as an automatic shut-off system, ensuring peace of mind when the unit is in use. Additionally, the built-in oxygen depletion sensor monitors air quality and will shut down the heater if levels become unsafe, allowing for uninterrupted safety during operation.

In terms of installation, the Desa V3610ST does not require extensive modifications. It is designed for both vented and unvented applications, providing flexibility based on a user’s individual needs. This adaptability makes the unit suitable for various settings, from traditional homes to modern apartments.

Furthermore, the efficiency rating of the V3610ST is a key selling point. It boasts a high energy efficiency score, helping users save on heating bills while minimizing their carbon footprint. The combination of practicality, safety, and efficiency makes the Desa V3610ST a compelling choice for consumers looking to enhance their heating solutions.

In conclusion, the Desa V3610ST offers an impressive array of features, advanced technologies, and robust safety measures. Whether you are looking to heat a small living space or a larger area, this versatile unit promises reliability, style, and efficiency, making it a top contender in the heating appliance market.