GAS LINE INSTALLATION

Continued

WARNING: After ensuring that the gas valve is ON, test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Note: An appropriate DESA hood (see Replacement and Accessory Parts, page 16) must be installed when using an unvented gas log set.

CAUTION: When using a decorative appliance, the damper must be removed or permanently locked in the open position.

VENTING INSTALLTION

PIPE INSTALLATION

Place pipe assembly (inner and outer with wire spacer) over starter collar. Inner pipe(s) fit inside inner pipe(s). Outer pipe fits outside outer pipe.

Begin by aligning hemmed end of inner flue pipe into the inner starting flue pipe of fireplace. Push down until hem “snap-locks” with lances. The outer pipe is just the opposite, the female end has the lances. Continue the same procedure for the outer pipe (see Figure 16). It is important to assure thejointsbetweenthechimneysectionsarefullylocked.Checkbypulling chimney upward after locking pipe hem(s). The chimney should not come apart if properly locked. It is not necessary to add screws to keep vertical or angled chimney runs together.

WARNING: The opening around the starter collar on top of the fireplace must never be obstructed. Never use blown insulation to fill the chimney enclosure.

15" (35.1cm) Galvanized Outer Pipe

CHIMNEY PIPE INSTALLATION

The DESA chimney system is a snap-lock, double wall pipe. It consists of a stainless steel inner flue pipe(s), a galvanized outer pipe, and a wire spacer.

Each section of pipe comes in lengths of 12, 18, 36, and 48 inches, but the actual lineal gain for each is measured after each section is fully connected. Lineal gain is the actual measurable length of a part after two or more parts are connected.

MODEL NO.

DESCRIPTION

GAIN

V3610ST

See-Through"

52 3/4"

 

Fireplace

 

48-10DM/48-10TM

Flue Pipe

46 5/8"

36-10DM/48-10TM

Flue Pipe

34 5/8"

18-10DM/48-10TM

Flue Pipe

16 5/8"

12-10DM/48-10TM

Flue Pipe

10 5/8"

ETL-10DM

Chase Style

1" to 12"

 

Termination

 

RTT-10

Round Top Termination

6"

 

 

 

RTL-10DM

Round Top Termination

7"

For more

Hemmed

Ends

10" (25.4cm)

Stainless Inner

Pipe Lanced

Side Up

Figure 16 - Pipe Connection

FIRESTOP SPACERS

Firestop spacers are required at each point where the chimney penetrates a floor or ceiling joist space. Their purpose is twofold. They establish and maintain the required clearance between the outer pipe and combustible materials, they also serve as a shield between floors as required by most codes.

When penetrating a floor or ceiling at an angle, use firestop spacer number 30 FS-10DM (see Replacement and Accessory Parts, back page).

When the pipe passes through a framed opening into a living space above, a firestop must be placed on the ceiling below (see Figure 17, page 9). When the pipe passes through a framed opening into an attic space above, a firestop must be placed on the attic floor above (see Figure 18, page 9).

visit www..com

55253C

Image 8
Contents Save this Book For Your SafetySavannah Table of Contents Product DimensionsBefore YOU Begin Safety InformationIntroduction Fireplace Installation Selecting LocationClearances Mantle ClearancesFraming MINHearth Extensions 7cmOutside AIR KIT Installation GAS Line InstallationGAS Line Installation Venting Installtion Pipe InstallationChimney Pipe Installation Firestop SpacersElbow Offset Installation Support SectionsFinishing Your Chimney System Foot RuleMinimum Chimney Height Maximum Chimney HeightChimney Maintenance Roof Opening ChartTerminations Flashing InstallationStorm Collar Installation Installing Fireplace Facing Chase InstallationGlass Doors Operating Guidelines and Maintenance InstructionsCleaning the Glass Technical Service Damper MechanismOutside AIR Mechanism GrateReplacement and Accessory Parts 18/12 to 24/12Owners Registration Form Postage Required 55253C Not a UPC

V3610ST specifications

The Desa V3610ST is an innovative solution designed to meet the heating needs of residential and commercial spaces. Renowned for its reliability and efficiency, this model stands out in the market with several noteworthy features and technologies.

At the heart of the Desa V3610ST lies its advanced heating technology. It utilizes a powerful yet energy-efficient propane gas system, delivering a maximum output of 30,000 BTUs. This ensures effective heating for medium-sized rooms, providing comfort during the cold months. The integrated thermostat allows for precise temperature control, enabling users to set their desired ambiance easily and efficiently.

One of the standout characteristics of the V3610ST is its sleek and modern design. The unit is finished in a stylish black or white, which allows it to blend seamlessly with various interior décors. Its compact size ensures that it doesn't take up excessive space, making it ideal for smaller rooms or apartments.

Another significant aspect of the Desa V3610ST is its user-friendly interface. The control panel is intuitive, allowing users to adjust settings effortlessly. The easy-to-read display gives real-time feedback on temperature settings, operating modes, and system diagnostics, ensuring optimal performance and ease of use.

The V3610ST also places a strong emphasis on safety. It comes equipped with advanced safety features such as an automatic shut-off system, ensuring peace of mind when the unit is in use. Additionally, the built-in oxygen depletion sensor monitors air quality and will shut down the heater if levels become unsafe, allowing for uninterrupted safety during operation.

In terms of installation, the Desa V3610ST does not require extensive modifications. It is designed for both vented and unvented applications, providing flexibility based on a user’s individual needs. This adaptability makes the unit suitable for various settings, from traditional homes to modern apartments.

Furthermore, the efficiency rating of the V3610ST is a key selling point. It boasts a high energy efficiency score, helping users save on heating bills while minimizing their carbon footprint. The combination of practicality, safety, and efficiency makes the Desa V3610ST a compelling choice for consumers looking to enhance their heating solutions.

In conclusion, the Desa V3610ST offers an impressive array of features, advanced technologies, and robust safety measures. Whether you are looking to heat a small living space or a larger area, this versatile unit promises reliability, style, and efficiency, making it a top contender in the heating appliance market.