FIREPLACE INSTALLATION

Selecting Location

Clearances

Mantle Clearances

FIREPLACE INSTALLATION

SELECTING LOCATION

To determine the safest and most efficient location for your fire- place, you must take into consideration the following guidelines:

1.The location must allow for all the proper clearances (see Fig- ure 2).

2.Consider a location where the heat output would not be af- fected by drafts, air conditioning ducts, windows or doors.

3.A location that avoids the cutting of joists or roof rafters will make installation easier.

4.If an outside air kit is to be installed, accessibility to outside combustion air must be considered. This can also be achieved through a vented crawl space in some cases, for more details refer to the section on outside air kit installation.

The typical installation for a V3610ST is a projected installation, which allows you to extend the fireplace any distance into the room. A projection may be ideal for a new addition on an existing, finished wall.

CLEARANCES

MINIMUM CLEARANCES TO COMBUSTIBLES

Back

1" Min.

Adjacent Wall

12" Min.

Chimney Outer Pipe Surfaces

2" Min.

Bottom Of Fireplaces To Floor

0" Min.

CAUTION: Do not block required air spaces with insulation or any other material. Do not obstruct effective opening of fireplace with any type of facing material. Combustible material must not be in con- tact with the black front face of the fireplace.

Figure 2 - Plan View of Common LocationFigure 3 - Fireplace Clearances

MANTLE CLEARANCES

Woodwork, such as wood trims, mantles, and other combustible materials, should not be placed within 9 inches of the effective opening of this fireplace.

Combustible material above and projecting more than 1 1/2 inches from the fireplace’s front face (see Figure 4, page 5), should not be placed less than 12 inches from the effective opening of the fireplace (Ref: NFPA std.7-3.3.3.).

Mantles or any other combustible material may also come up to the side edge of the black metal face of the fireplace, but only if the projection from the front face falls within the limits shown in Figure 5, page 5.

For morevisit www..com

55253C

Image 4
Contents Savannah For Your SafetySave this Book Table of Contents Product DimensionsIntroduction Safety InformationBefore YOU Begin Fireplace Installation Selecting LocationClearances Mantle ClearancesFraming MINHearth Extensions 7cmOutside AIR KIT Installation GAS Line InstallationGAS Line Installation Venting Installtion Pipe InstallationChimney Pipe Installation Firestop SpacersElbow Offset Installation Support SectionsFinishing Your Chimney System Foot RuleMinimum Chimney Height Maximum Chimney HeightChimney Maintenance Roof Opening ChartStorm Collar Installation Flashing InstallationTerminations Installing Fireplace Facing Chase InstallationCleaning the Glass Operating Guidelines and Maintenance InstructionsGlass Doors Technical Service Damper MechanismOutside AIR Mechanism GrateReplacement and Accessory Parts 18/12 to 24/12Owners Registration Form Postage Required 55253C Not a UPC

V3610ST specifications

The Desa V3610ST is an innovative solution designed to meet the heating needs of residential and commercial spaces. Renowned for its reliability and efficiency, this model stands out in the market with several noteworthy features and technologies.

At the heart of the Desa V3610ST lies its advanced heating technology. It utilizes a powerful yet energy-efficient propane gas system, delivering a maximum output of 30,000 BTUs. This ensures effective heating for medium-sized rooms, providing comfort during the cold months. The integrated thermostat allows for precise temperature control, enabling users to set their desired ambiance easily and efficiently.

One of the standout characteristics of the V3610ST is its sleek and modern design. The unit is finished in a stylish black or white, which allows it to blend seamlessly with various interior décors. Its compact size ensures that it doesn't take up excessive space, making it ideal for smaller rooms or apartments.

Another significant aspect of the Desa V3610ST is its user-friendly interface. The control panel is intuitive, allowing users to adjust settings effortlessly. The easy-to-read display gives real-time feedback on temperature settings, operating modes, and system diagnostics, ensuring optimal performance and ease of use.

The V3610ST also places a strong emphasis on safety. It comes equipped with advanced safety features such as an automatic shut-off system, ensuring peace of mind when the unit is in use. Additionally, the built-in oxygen depletion sensor monitors air quality and will shut down the heater if levels become unsafe, allowing for uninterrupted safety during operation.

In terms of installation, the Desa V3610ST does not require extensive modifications. It is designed for both vented and unvented applications, providing flexibility based on a user’s individual needs. This adaptability makes the unit suitable for various settings, from traditional homes to modern apartments.

Furthermore, the efficiency rating of the V3610ST is a key selling point. It boasts a high energy efficiency score, helping users save on heating bills while minimizing their carbon footprint. The combination of practicality, safety, and efficiency makes the Desa V3610ST a compelling choice for consumers looking to enhance their heating solutions.

In conclusion, the Desa V3610ST offers an impressive array of features, advanced technologies, and robust safety measures. Whether you are looking to heat a small living space or a larger area, this versatile unit promises reliability, style, and efficiency, making it a top contender in the heating appliance market.