Desa S42RH, VS42(1), VS42H(1) installation manual Firestop Spacers FS-8DM, Penetrating the Roof

Page 8

VENTING INSTALLATION

Continued

See Detail A

2" Min.

Existing

Ceiling

Frame

Firestop

Spacer

Straps

 

 

Straps

 

 

Detail B

See Detail B

 

Angle Firestop

 

 

Straps

Straps

 

 

 

Detail A

 

Return Elbow

 

Figure 8 - Ceiling Support Pipe

 

12S-8DM

 

 

Screws or

 

Staples

 

(Min. of 8)

Figure 10 - Firestop Spacer with Living

 

Space Above Ceiling

Firestop

Screws or Staples

(Min. of 8)

Spacer

 

 

Existing

 

Ceiling

 

Frame

Figure 11 - Firestop Spacer with Attic

Space Above Ceiling

Screws

B

A

Figure 9 - Elbow Offset

FIRESTOP SPACERS (FS-8DM)

Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 10.

They also provide complete separation from one floor space to another or attic space as required by most codes. When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 11.

PENETRATING THE ROOF

To maintain a 1" clearance to the pipe on a roof with a pitch, a rectangular opening must be cut.

1.Determine the center point through which the pipe will penetrate the roof.

2.Determine the center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters.

3.Use the roof opening chart (Figure 12, page 9) to determine the correct opening length and flashing required.

4.Remove the shingles around the opening measured. Cut out this section.

5.Add the next sections of the pipe until the end penetrates the roof line. Check to see that the proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above the highest point of the roof cutout. Termination and chimney must extend a minimum of 36" above the highest point where it passes through the roof.

8

www.desatech.com

111099-01C

Image 8
Contents Save this Book Table of Contents Safety InformationSpecifications Framing Selecting LocationMinimum Clearance to Combustibles Hearth Extension MantelsVenting Installation Assembly and InstallationOptional Outside AIR KIT Model AK4/AK4F Chimney PipeUsing Elbow Offsets 30E-8DM Elbow SET onlyFirestop Spacers FS-8DM Penetrating the RoofFlashing Installation V6F-8DM or V12F-8DM Storm Collar Installation SC1 or SC2Finishing the Fireplace Chase InstallationsFoot Rule Optional GAS Line Installation Typical Residential InstallationsOperation Maintenance Guidelines Glass DoorsTechnical Service Outside AIR and Damper Handle OperationIllustrated Parts Breakdown Woodburning Fireplace ModelsParts List QTY KEY NO. Part no DescriptionReplacement Parts Accessories111099-01C 111099-01C 111099-01C Not a UPC

S42RH, S42R, VS42(1), VS42H(1), S42H specifications

Desa VS42(1), S42RH, VS42H(1), S42H, and S42R are part of a comprehensive line of residential heating appliances designed to offer efficient and effective heating solutions for various living spaces. These models are known for their unique features, advanced technologies, and characteristics that set them apart in the market of home heating.

The Desa VS42(1) model boasts a sleek design with an emphasis on modern aesthetics while maintaining functional excellence. It features advanced thermostatic controls that allow users to maintain their desired temperature effortlessly. The efficient combustion system maximizes fuel usage, ensuring a higher output of heat with minimal emissions, thereby promoting an eco-friendly approach to home heating.

Similarly, the S42RH model is equipped with cutting-edge safety features, including automatic shut-off systems that prevent overheating and potential accidents. Its innovative design also allows for easy installation, making it a popular choice for homeowners looking to upgrade their heating systems. The versatile design is suitable for various home styles, seamlessly fitting into traditional or contemporary settings.

The VS42H(1) variant stands out due to its compatibility with smart home systems, allowing users to control the heating remotely through smartphone applications. This level of convenience is enhanced by its energy-efficient operation, which reduces heating costs while ensuring a comfortable living environment. Furthermore, this model incorporates high-quality insulation materials that improve heat retention for longer periods.

In contrast, the S42H model emphasizes user-friendly operation without compromising performance. Its straightforward controls and efficient heating technology make it an ideal choice for families. The model also offers multiple heating settings to cater to different environments and user preferences, providing customizable comfort.

Finally, the S42R offers remarkable adaptability, featuring a flexible venting system that permits installation in various locations within the home. This versatility is complemented by its robust build quality that ensures durability and longevity. The combination of these characteristics makes the S42R an attractive choice for homeowners seeking reliability and performance.

In summary, the Desa VS42(1), S42RH, VS42H(1), S42H, and S42R models present a range of features aimed at enhancing user experience while prioritizing energy efficiency and safety. These appliances are designed to meet the diverse needs of consumers, ensuring that comfort and functionality go hand in hand.