Desa S42RH, S42H, VS42(1) Technical Service, Outside AIR and Damper Handle Operation

Page 13

OPERATION AND

MAINTENANCE

GUIDELINES

Continued

A fireplace equipped with glass doors operates mush differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion. Excessive heat within the fireplace can result if too large a fire is built or if the combustion air gate is not com- pletely open.

The following tips should be followed to assure that both the fireplace and the glass door retain their beauty and function properly. Both the flue damper and the glass doors must be fully opened before starting the fire. This will provide sufficient combustion air and maintain safe temperatures in the firebox.

IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep the fire well back from the doors and never allow flames to contact the glass.

WARNING: Fireplaces equipped with glass doors should be operated only with doors fully opened or doors fully closed. Doors, if left partly open, may draw gas and flame out of the fireplace opening creating risks of both fire and smoke.

Cleaning the Glass

Clean the glass with any commercial glass cleaner or soap and water. Do not use any abrasive mate- rial to clean the glass. Do not clean the glass with any cool water is the glass is still hot from the fire and smoke.

A gas line or gas log lighter may be installed for the purpose of installing a vented or vent-free decorative gas appliance incorporating an automatic shutoff de- vice and complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft re- quirements for Gas Fired Log Lighters for Wood Burn- ing Fireplaces, Draft NO. 4 dated August, 1993.

If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which have been found to comply with the standard for unvented room heaters, ANSI Z21.11.2 are to be installed in this fireplace.

OUTSIDE AIR AND DAMPER HANDLE OPERATION

The damper handle, which opens and closes the damper blade, is located in the upper front face of the fireplace. Pushing the handle into the left of the keyway slot will free the damper blade to automati- cally open. Pushing the handle in to the right will lock the damper blade closed (see Figure 22).

The outside air kit handle is located at the left hand side of the fireplace (see Figure 22). Pulling the handle out will free the outside air door to open. Pushing the handle in will lock the door closed.

WARNING:Riskoffire!Replace grate with DESA model 111100-01 only.Thisgratehasbeendesigned to keep the operation of your fire- place safe and efficient.

For further operating guidelines, instructions and warranty information, please refer to your home- owner's guide or contact your authorized dealer.

Damper

 

Handle

Keyway

 

 

Slot

OPEN

 

 

CLOSE

Outside Air

Handle

Kit Handle

Retainer

Figure 22 - Damper and Air Kit Handle

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESAʼs Technical Service Department at 1-866-672-6040. When calling please have your model and serial numbers of your heater ready.

You can also visit DESAʼs technical services web site at www.desatech.com.

111099-01C

www.desatech.com

13

Image 13
Contents Save this Book Safety Information Table of ContentsSpecifications Minimum Clearance to Combustibles Selecting LocationFraming Mantels Hearth ExtensionAssembly and Installation Venting InstallationOptional Outside AIR KIT Model AK4/AK4F Chimney PipeElbow SET only Using Elbow Offsets 30E-8DMPenetrating the Roof Firestop Spacers FS-8DMStorm Collar Installation SC1 or SC2 Flashing Installation V6F-8DM or V12F-8DMFoot Rule Chase InstallationsFinishing the Fireplace Typical Residential Installations Optional GAS Line InstallationGlass Doors Operation Maintenance GuidelinesOutside AIR and Damper Handle Operation Technical ServiceWoodburning Fireplace Models Illustrated Parts BreakdownQTY KEY NO. Part no Description Parts ListAccessories Replacement Parts111099-01C 111099-01C 111099-01C Not a UPC

S42RH, S42R, VS42(1), VS42H(1), S42H specifications

Desa VS42(1), S42RH, VS42H(1), S42H, and S42R are part of a comprehensive line of residential heating appliances designed to offer efficient and effective heating solutions for various living spaces. These models are known for their unique features, advanced technologies, and characteristics that set them apart in the market of home heating.

The Desa VS42(1) model boasts a sleek design with an emphasis on modern aesthetics while maintaining functional excellence. It features advanced thermostatic controls that allow users to maintain their desired temperature effortlessly. The efficient combustion system maximizes fuel usage, ensuring a higher output of heat with minimal emissions, thereby promoting an eco-friendly approach to home heating.

Similarly, the S42RH model is equipped with cutting-edge safety features, including automatic shut-off systems that prevent overheating and potential accidents. Its innovative design also allows for easy installation, making it a popular choice for homeowners looking to upgrade their heating systems. The versatile design is suitable for various home styles, seamlessly fitting into traditional or contemporary settings.

The VS42H(1) variant stands out due to its compatibility with smart home systems, allowing users to control the heating remotely through smartphone applications. This level of convenience is enhanced by its energy-efficient operation, which reduces heating costs while ensuring a comfortable living environment. Furthermore, this model incorporates high-quality insulation materials that improve heat retention for longer periods.

In contrast, the S42H model emphasizes user-friendly operation without compromising performance. Its straightforward controls and efficient heating technology make it an ideal choice for families. The model also offers multiple heating settings to cater to different environments and user preferences, providing customizable comfort.

Finally, the S42R offers remarkable adaptability, featuring a flexible venting system that permits installation in various locations within the home. This versatility is complemented by its robust build quality that ensures durability and longevity. The combination of these characteristics makes the S42R an attractive choice for homeowners seeking reliability and performance.

In summary, the Desa VS42(1), S42RH, VS42H(1), S42H, and S42R models present a range of features aimed at enhancing user experience while prioritizing energy efficiency and safety. These appliances are designed to meet the diverse needs of consumers, ensuring that comfort and functionality go hand in hand.