Desa VTD-18P-PDG, VTD-24N-BTB, VTD-24N-PDG Pressure Testing Appliance Gas Connections, Valve

Page 10

10

INSTALLATION

Pressure Testing Gas Supply Piping System (Cont.)

 

 

Pressure Testing Appliance Gas Connections

 

 

INSTALLATION

Continued

4.Check all joints of gas supply piping system. Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect appliance and equipment shutoff valve to gas supply. Check reconnected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 10).

2.Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air.

3.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figure 11). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Pressure Testing Appliance Gas Connections

1.Open equipment shutoff valve (see Figure 10).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of appliance is in the OFF position.

4.Check all joints from equipment shutoff valve to gas control (see Figures 11 and 12). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light appliance (see Operating Appliance, pages 11 through 13). Check all other internal joints for leaks.

7.Turn off appliance.

Equipment

ON

Open

Shutoff

POSITION

 

 

Valve

 

 

 

OFF

Closed

 

POSITION

 

Figure 10 - Equipment Shutoff Valve

Equipment

Shutoff Valve

Propane/LP

Supply Tank

Control Valve Location

Figure 11- Checking Gas Joints (propane/LP only)

Equipment

 

Shutoff Valve

Control Valve Location

Gas Meter

Figure 12 - Checking Gas Joints (Natural Gas Only)

For more information, visit www.desatech.com

111826-02C

Image 10
Contents What to do if YOU Smell GAS GAS LOG Vented Decorative ApplianceAnsi Z21.60a-2000 CSA 2.26a-2000 Table of Contents Safety InformationLocal Codes Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation AIRVentilation Air from Outdoors Installation Connecting to GAS Supply Installing Appliance AssemblyInstallation Items Needed Pressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Appliance Gas Connections ValveOperating Appliance For Your Safety Read Before LightingLighting Instructions Remote Control Operation Manual Lighting ProcedureTo Turn OFF GAS to Appliance Pilot Flame Pattern Cleaning and MaintenanceOperating Appliance Inspecting Burner Burner Flame PatternTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Observed Problem Possible Cause Specifications VTD-18N-PDG/VTD-18N-BTBService Hints Wiring DiagramReplacement Parts Technical ServiceThis page Intentionally Left Blank Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Accessories Owners Registration Form Postage Required 111826-02C Warranty Information

VTD-18P-PDG, VTD-24N-PDG, VTD-24N-BTB specifications

The Desa VTD-24N-BTB, VTD-24N-PDG, and VTD-18P-PDG are advanced heating solutions that reflect the latest innovations in consumer comfort technology. Designed for residential and commercial applications, these units are recognized for their efficiency, performance, and user-friendly features.

The Desa VTD-24N-BTB model is a powerful heater that operates on a 24,000 BTU output. It features a sleek, modern design that allows it to integrate seamlessly into various room aesthetics. One of its standout characteristics is its variable flame height control, enabling users to adjust the heat output according to their needs. This function contributes not only to comfort but also to energy efficiency, reducing unnecessary fuel consumption. Built with high-quality materials, the VTD-24N-BTB is designed for durability and longevity, making it a reliable heating choice for years to come.

Similarly, the VTD-24N-PDG model shares several common features with the BTB version but focuses on a different aesthetic and design philosophy. It is equipped with a programmable thermostat that enhances user convenience, allowing homeowners to set schedules according to their lifestyle. This model also includes a high-efficiency fan system that circulates warm air more effectively throughout the space, ensuring even temperature distribution. The VTD-24N-PDG is an excellent choice for consumers looking for a balance between modern styling and advanced heating technology.

The VTD-18P-PDG model, while slightly smaller with an 18,000 BTU output, does not compromise on performance. It remains equipped with a plethora of features, including an easy-to-read LCD display that provides real-time information about temperature settings and system performance. This model is particularly appealing to those with limited space, offering a compact design without sacrificing heating capacity. The VTD-18P-PDG also includes safety features such as an automatic shut-off system, ensuring peace of mind for users.

All three models leverage advanced heating technologies, such as electronic ignition systems and adjustable flame technology, to maximize efficiency and comfort. With a commitment to environmentally-friendly solutions, these units utilize a low-emission combustion system, contributing to a reduced carbon footprint.

In summary, the Desa VTD-24N-BTB, VTD-24N-PDG, and VTD-18P-PDG heaters represent a blend of functionality, safety, and style. With their innovative features and efficiency-driven designs, they cater to diverse heating needs, making them an ideal investment for any modern living or working space.