Desa VTD-24N-PDG, VTD-24N-BTB, VTD-18P-PDG Installing Appliance Assembly, Connecting to GAS Supply

Page 8

8

INSTALLATION

Installing Appliance Assembly

Connecting To Gas Supply

INSTALLATION

Continued

INSTALLING APPLIANCE ASSEMBLY

WARNING: If installing in a sunken fireplace, spe- cial care is needed.You must raise the fireplace floor to allow access to appliance control panel. This will insure adequate air flow and guard against sooting. Raise fireplace floor with noncombustible material. Make sure material is secure.

CAUTION: Do not pick up appliance assembly by logs. This could damage unit. Only handle assembly by grates.

IMPORTANT: Make sure the appliance is level. If unit is not level, unit will not work properly.

Installation Items Needed

control cover kit (provided with appliance)

approved flexible gas hose and fittings (provided with appliance) (if allowed by local codes)

sealant (resistant to propane/LP gas, not provided)

Note: Install optional Hand-Held Remote Control Kit (see Acces- sories, page 22) before installing gas log appliance (Remote-Ready Models Only). See installation instructions included with the kit.

1.Apply pipe joint sealant lightly to male threads of gas fitting (not provided). Connect approved flexible gas hose to inlet side of gas control (see Figure 7).

2.Position appliance in fireplace.

3.Connect to gas supply. See Connecting To Gas Supply.

Gas Control

Flexible Gas Hose (if allowed by local codes)

Figure 7 - Attaching Flexible Gas Hose to Gas Regulator

CONNECTING TO GAS SUPPLY

WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pres- sure regulator.

WARNING:Aqualifiedservicepersonmustconnect appliance to gas supply. Follow all local codes.

CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This unit requires an external regulator (not supplied).Install the external regulator between the unit and propane/LP supply.

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing appliance, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connector (if allowed by local codes) (provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA design-certified equipment shutoff valve from your dealer. See Accessories, page 22.

For propane/LP units, the installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure.You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, regulator dam- age could occur. Install external regulator with the vent pointing down as shown in Figure 8 page 9. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to appliance. If pipe is too small, undue loss of volume will occur.

For more information, visit www.desatech.com

111826-02C

Image 8
Contents Ansi Z21.60a-2000 CSA 2.26a-2000 GAS LOG Vented Decorative ApplianceWhat to do if YOU Smell GAS Table of Contents Safety InformationLocal Codes Product IdentificationOptional Remote Control Accessories Product FeaturesUnpacking AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation AIRVentilation Air from Outdoors Installation Installation Items Needed Installing Appliance AssemblyConnecting to GAS Supply Pressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Appliance Gas Connections ValveLighting Instructions For Your Safety Read Before LightingOperating Appliance To Turn OFF GAS to Appliance Manual Lighting ProcedureRemote Control Operation Cleaning and Maintenance Operating Appliance Inspecting BurnerPilot Flame Pattern Burner Flame PatternTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Observed Problem Possible Cause Specifications VTD-18N-PDG/VTD-18N-BTBWiring Diagram Replacement PartsService Hints Technical ServiceThis page Intentionally Left Blank Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Accessories Owners Registration Form Postage Required 111826-02C Warranty Information

VTD-18P-PDG, VTD-24N-PDG, VTD-24N-BTB specifications

The Desa VTD-24N-BTB, VTD-24N-PDG, and VTD-18P-PDG are advanced heating solutions that reflect the latest innovations in consumer comfort technology. Designed for residential and commercial applications, these units are recognized for their efficiency, performance, and user-friendly features.

The Desa VTD-24N-BTB model is a powerful heater that operates on a 24,000 BTU output. It features a sleek, modern design that allows it to integrate seamlessly into various room aesthetics. One of its standout characteristics is its variable flame height control, enabling users to adjust the heat output according to their needs. This function contributes not only to comfort but also to energy efficiency, reducing unnecessary fuel consumption. Built with high-quality materials, the VTD-24N-BTB is designed for durability and longevity, making it a reliable heating choice for years to come.

Similarly, the VTD-24N-PDG model shares several common features with the BTB version but focuses on a different aesthetic and design philosophy. It is equipped with a programmable thermostat that enhances user convenience, allowing homeowners to set schedules according to their lifestyle. This model also includes a high-efficiency fan system that circulates warm air more effectively throughout the space, ensuring even temperature distribution. The VTD-24N-PDG is an excellent choice for consumers looking for a balance between modern styling and advanced heating technology.

The VTD-18P-PDG model, while slightly smaller with an 18,000 BTU output, does not compromise on performance. It remains equipped with a plethora of features, including an easy-to-read LCD display that provides real-time information about temperature settings and system performance. This model is particularly appealing to those with limited space, offering a compact design without sacrificing heating capacity. The VTD-18P-PDG also includes safety features such as an automatic shut-off system, ensuring peace of mind for users.

All three models leverage advanced heating technologies, such as electronic ignition systems and adjustable flame technology, to maximize efficiency and comfort. With a commitment to environmentally-friendly solutions, these units utilize a low-emission combustion system, contributing to a reduced carbon footprint.

In summary, the Desa VTD-24N-BTB, VTD-24N-PDG, and VTD-18P-PDG heaters represent a blend of functionality, safety, and style. With their innovative features and efficiency-driven designs, they cater to diverse heating needs, making them an ideal investment for any modern living or working space.