Desa VTD-24N-PDG Operating Appliance, For Your Safety Read Before Lighting, Lighting Instructions

Page 11

OPERATING APPLIANCE

REMOTE-READY MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: Keep flue open when operating unit.

OPERATING APPLIANCE (REMOTE-READY MODELS) 11

For Your Safety Read Before Lighting

Lighting Instructions

 

Selector Switch in

Control Knob

OFF Position

 

O

 

IL

T

 

P

O

 

F

N

 

F

 

 

O

OL

 

 

AUTO

 

 

 

 

OFF

 

 

ON

 

HI

 

Ignitor Button

Flame Adjustment Knob

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

NOTICE: During initial operation of new appliance, burning logs will give off a paper-burning smell. Or- ange flame will also be present. Open damper or win- dow to vent smell. This will only last a few hours.

WARNING: Damper handle will be hot if appliance has been running.

Figure 13 - Control Knob and Ignitor Button Location, Remote Ready Units.

1.STOP! Read the safety information, starting in column 1, of this page.

2.Make sure equipment shutoff valve is fully open.

3.Set selector switch in the OFF position.

4.Press in and turn control knob clockwise to the OFF position (see Figure 13).

WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, starting in column 1 of this page. If you don’t smell gas, go to the next step.

6.Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5)

seconds (see Figure 13).

Note: You may be running this appliance for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

7.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 12.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8.

For more information, visit www.desatech.com

111826-02C

Image 11
Contents Ansi Z21.60a-2000 CSA 2.26a-2000 GAS LOG Vented Decorative ApplianceWhat to do if YOU Smell GAS Safety Information Table of ContentsProduct Identification Local CodesAIR for Combustion and Ventilation Optional Remote Control AccessoriesProduct Features UnpackingVentilation AIR Determining FRESH-AIR Flow for Appliance LocationVentilation Air from Outdoors Installation Installation Items Needed Installing Appliance AssemblyConnecting to GAS Supply Checking GAS Connections Pressure Testing gas Supply Piping systemValve Pressure Testing Appliance Gas ConnectionsLighting Instructions For Your Safety Read Before LightingOperating Appliance To Turn OFF GAS to Appliance Manual Lighting ProcedureRemote Control Operation Burner Flame Pattern Cleaning and MaintenanceOperating Appliance Inspecting Burner Pilot Flame PatternObserved Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Observed Problem Possible Cause VTD-18N-PDG/VTD-18N-BTB SpecificationsTechnical Service Wiring DiagramReplacement Parts Service HintsThis page Intentionally Left Blank Illustrated Parts Breakdown Illustrated Parts BreakdownParts List Accessories Owners Registration Form Postage Required 111826-02C Warranty Information

VTD-18P-PDG, VTD-24N-PDG, VTD-24N-BTB specifications

The Desa VTD-24N-BTB, VTD-24N-PDG, and VTD-18P-PDG are advanced heating solutions that reflect the latest innovations in consumer comfort technology. Designed for residential and commercial applications, these units are recognized for their efficiency, performance, and user-friendly features.

The Desa VTD-24N-BTB model is a powerful heater that operates on a 24,000 BTU output. It features a sleek, modern design that allows it to integrate seamlessly into various room aesthetics. One of its standout characteristics is its variable flame height control, enabling users to adjust the heat output according to their needs. This function contributes not only to comfort but also to energy efficiency, reducing unnecessary fuel consumption. Built with high-quality materials, the VTD-24N-BTB is designed for durability and longevity, making it a reliable heating choice for years to come.

Similarly, the VTD-24N-PDG model shares several common features with the BTB version but focuses on a different aesthetic and design philosophy. It is equipped with a programmable thermostat that enhances user convenience, allowing homeowners to set schedules according to their lifestyle. This model also includes a high-efficiency fan system that circulates warm air more effectively throughout the space, ensuring even temperature distribution. The VTD-24N-PDG is an excellent choice for consumers looking for a balance between modern styling and advanced heating technology.

The VTD-18P-PDG model, while slightly smaller with an 18,000 BTU output, does not compromise on performance. It remains equipped with a plethora of features, including an easy-to-read LCD display that provides real-time information about temperature settings and system performance. This model is particularly appealing to those with limited space, offering a compact design without sacrificing heating capacity. The VTD-18P-PDG also includes safety features such as an automatic shut-off system, ensuring peace of mind for users.

All three models leverage advanced heating technologies, such as electronic ignition systems and adjustable flame technology, to maximize efficiency and comfort. With a commitment to environmentally-friendly solutions, these units utilize a low-emission combustion system, contributing to a reduced carbon footprint.

In summary, the Desa VTD-24N-BTB, VTD-24N-PDG, and VTD-18P-PDG heaters represent a blend of functionality, safety, and style. With their innovative features and efficiency-driven designs, they cater to diverse heating needs, making them an ideal investment for any modern living or working space.