Vermont Casting VL24LP, VL18LP Lighting and Operating Instructions, To Turn Off Gas To Heater

Page 12

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A. This heater has a pilot which must be lit manu-

ally. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neigh- bor’s phone. Follow the gas supplier’s instruc- tions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas con- trol knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to “OFF”.

 

 

 

 

PILOT

PILOT

OFF

 

 

 

 

 

t

 

1

F

 

 

 

 

 

 

 

lo

 

 

ON

ON

 

P

 

 

 

F

 

 

F

 

i

 

2

 

 

 

 

O

 

O

 

 

 

F

 

 

 

 

 

 

5

 

3

 

FFO

 

 

4

 

 

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor- mation above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to “PILOT”.

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.Turn the On/Off switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clock-

wise to “OFF”. Do not force.

5.Close control access panel.

12

20002538

Image 12
Contents R N I N G What to do if YOU Smell GASGeneral Information T I C EInstallation Requirements Pressure Test PointsOdor During Operation High ElevationsInstallation Precautions PlanningFresh Air Requirements for Combustion and Ventilation Provide for Adequate VentilationUnusually Tight Construction Determine If You Have a Confined Or Unconfined SpaceVentilaton options for confined spaces Installation Instructions Damper Stop Installation Installation InstructionsBurner Assembly Location Gas Line ConnectionConnection to AN Unregulated LP Tank can Cause AN Explosion Do not Test for Leaks with AN Open FlamePositioning the Logs Fireplace ScreenClearances Without HoodVL24 log placement Lighting and Operating Instructions To Turn Off Gas To HeaterWhen Used as a Heating Appliance Maintenance and SafeguardsVL System Maintenance Logs can GET Very HOT. Handle only When CoolVL18 Troubleshooting Symptom Possible Causes Corrective ActionVL18/21/24 Standard Vent Free Gas Logs VL18/21/24 Standard Vent Free Gas Logs Accessories Description Model NoLimited 2/20 Year Warranty CFM Corporation