Vermont Casting SC42A, SR42A Installing Top Housing or Termination, Installing Chimney In a Chase

Page 14

SR/SC Series "A" Woodburning Fireplace

Installing Top Housing or Termination

Follow the installation instructions provided with the chimney termination you have selected.

Installing Chimney In a Chase

Refer to Page 5, Figure 5 for an illustration of a typical chase installation.

CAUTION: Treatment of firestop spacers and construc- tion of chase may vary with type of building. These instructions are not a substitute for local building codes. You must check your local building codes to determine specific requirements for your city or state. NOTE: Other building materials may be required in addition to Firestop Spacers.

Finishing

CAUTION: All joints between the finished wall and the fireplace surround (top/sides) must be sealed with noncombustible material to prevent cold air leakage into the room. Only noncombustible material may be applied to the facing of the fireplace surround. (Black painted area) (Fig. 20)

Finish Wall

Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12" (305mm) from the top of the fireplace opening for radiant models and 12" (305mm) from top of grille opening for circulating models. Do not install a mantel face plate less than 6" (159mm) from top of fireplace opening for radiant models and 6" (159mm) from top of grille opening for circulating models. (Fig. 22) If a combustible material is used be- low a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf.

All joints (top, bottom and sides) where wall or deco- rative facing material meets fireplace surround must be completely sealed with a noncombustible material. (Figs. 21 and 22)

NOTE: No side wall protection is required for fireplaces installed at 45° to two (2) side walls (corner installation).

Often a decorative surround or vertical portion of the mantel is desired. If this is constructed of any combus- tible material it must be within the safe zone indicated in Figure 23.

Air Space Clearances

Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas).

1���"

 

Standoff

1/2" air space

 

to sides

 

Front View

Side View

 

Firestop

Wall

1/2" Air

Shield

Space

 

to Back

 

1/2" Air

 

Space

 

to Sides

Only noncombustible

0" Clearance

to Floor

material may be applied

Hearth

as facing to the black

fireplace surround.

Extension

FP559

Fig. 20 Minimum clearances to combustibles.

14

7412948

Image 14
Contents SR/SC Series a Safety Information Table of ContentsSR36A Series Woodburning Fireplace SR42A Series Woodburning Fireplace SR/SC36A SR/SC42AOffset Rise 30˚ Elbow OffsetsIllustration Key OffsetPlanning the Chimney Run Planning InformationMounting the Fireplace Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesChimney Setup Installing Electrical Wire For Circulator ModelsInstall Fan Kit Assembly FramingCeiling Chimney Hole Possible Obstructions Straight-Up Chimney InstallationOffset Installation Cutting the HoleInstalling the Chimney System Positioning, Safety Strips Securing the FireplaceInstalling Outside Air Kit Angle of Chimney at CeilingCanadian Requirements For Insulation Shield Installing the Firestop Spacer Ceiling HoleProper Firestop Spacer Installation Elbow Strap Angled StrapAdditional Ceilings Continue Installing Pipe to Complete RunInstall Remainder of Chimney Sections Penetrating the RoofFinishing Finish Wall Installing Top Housing or TerminationInstalling Chimney In a Chase Top View MaterialMinimum Wall Clearances Side Wall Protection Hearth InstallationMinimum Hearth Extension Dimensions Noncombustible Surround FacingSide View EH2416Installing Line for Gas Logs Fireplace Top ViewSR36A/42A, SC36A/42A Series Accessories Chimney Components CCE-SK AIS-SKFan Motor For Majestic Fireplaces PRE-ENGINEERED Fireplace SystemsFiregrate, Glass Doors, Outside Air System Liners Refractory or MetalCFM Corporation