Vermont Casting SC42A, SR42A, SR36A, SC36A manual Installing Line for Gas Logs, Fireplace Top View

Page 18

SR/SC Series "A" Woodburning Fireplace

Installing Line for Gas Logs

CFM Corporation fireplaces are designed to accept a 1/2" (13mm) gas line for installation of an approved gas appliance. (CFM Corporation manufactures a wide va- riety of gas logs for use in CFM Corporation fireplaces.)

Be sure to have the appliance installed in accordance with building codes.

Gas connection may enter from either left or right side of the fireplace.

Locate appropriate gas line in the outer casing of fire- place and remove insulation from gas line tube. (Fig. 26)

From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screw- driver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out.

Install 1/2" (13mm) certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.

NOTE: Gas pipe should not come in contact with any wood structures until it has reached a point at least one (1) inch away from fireplace side.

NOTE: When installing an ANSI Z21.11.2 ventless ap- pliance the finishing material used for the mantel must be rated at 250°F or greater.

BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr.

Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installa- tion in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for Gas-Fired Log Lighters for Woodburn- ing Fireplaces (Draft No. 4, August 1993).

Decorative gas appliance should be installed in accor- dance with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 (latest edition).

Hole in Outer Casing

Fireplace Top View

 

 

1"

 

Gas Line

Min.

Supply

Tube

 

Line

Ceramic

 

Repack Insula-

Knockout

 

tion

1/2"

Hole in

Casing

Ceramic

Knockout (Both sides)

FP560

Fig. 26 Gas line access.

CAUTION: WHEN USING DECORATIVE GAS APPLIANCE, FLUE DAMPER MUST BE SET IN FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE FIREPLACE, THEY MUST ALSO BE FULLY OPENED.

WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIRE- PLACE WITH THE CHIMNEY REMOVED.

WARNING: WHEN INSTALLING AN UNVENTED AS LOG SET, THE CFM Corpo- ration MODEL AH3244BK OR AH3244PB 4"

ADJUSTABLE HOOD MUST BE USED.

If installing an unvented gas log set, refer to statement below:

Only unvented gas logsets which have been found to com- ply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace.

18

7412948

Image 18
Contents SR/SC Series a Safety Information Table of ContentsSR36A Series Woodburning Fireplace SR42A Series Woodburning Fireplace SR/SC36A SR/SC42AOffset Rise 30˚ Elbow OffsetsIllustration Key OffsetPlanning the Chimney Run Planning InformationMounting the Fireplace Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesChimney Setup Installing Electrical Wire For Circulator ModelsInstall Fan Kit Assembly FramingCeiling Chimney Hole Possible Obstructions Straight-Up Chimney InstallationOffset Installation Cutting the HoleInstalling the Chimney System Positioning, Safety Strips Securing the FireplaceInstalling Outside Air Kit Angle of Chimney at CeilingCanadian Requirements For Insulation Shield Installing the Firestop Spacer Ceiling HoleProper Firestop Spacer Installation Elbow Strap Angled StrapAdditional Ceilings Continue Installing Pipe to Complete RunInstall Remainder of Chimney Sections Penetrating the RoofInstalling Top Housing or Termination Installing Chimney In a ChaseFinishing Finish Wall Top View MaterialMinimum Wall Clearances Side Wall Protection Hearth InstallationMinimum Hearth Extension Dimensions Noncombustible Surround FacingSide View EH2416Installing Line for Gas Logs Fireplace Top ViewSR36A/42A, SC36A/42A Series Accessories Chimney Components CCE-SK AIS-SKFan Motor For Majestic Fireplaces PRE-ENGINEERED Fireplace SystemsFiregrate, Glass Doors, Outside Air System Liners Refractory or MetalCFM Corporation