Desa VMH10TPB installation manual Attaching Wood Base to Solid Floor, Connecting to GAS Supply

Page 17

INSTALLATION

Installing Blower Accessory GA3450T in Thermostat-Controlled Models (Cont.) Attaching Wood Base to Solid Floor Connecting to Gas Supply

17

INSTALLATION

Continued

Extension Cord

CONNECTING TO GAS SUPPLY

Use extension cord if needed. The cord must have a three-prong, grounding plug and a three-hole receptacle. Make sure cord is in good shape. It must be heavy enough to carry the current needed. An undersized cord will cause a drop in line voltage. This will result in loss of power and overheating. Use a No. 16 AWG cord for lengths less than 50 feet.

ATTACHING WOOD BASE TO SOLID FLOOR

For attaching base to solid floors (concrete or masonry)

Note: Floor anchors and mounting screws are in hardware package. The hardware package is provided with fireplace.

1.Drill holes at marked locations using 5/16" drill bit. For solid floors (concrete or masonry), drill at least 1" deep.

2.Fold floor anchor as shown in Figure 28.

3.Insert floor anchor (wings first) into hole. Tap anchor flush to floor.

4.Insert mounting screws through base and into floor anchors.

5.Tighten screws until base is firmly fastened to floor.

Figure 28 - Folding Anchor

WARNING: This appliance requires a 45° male flare fitting 5/8"-18 UNF (Unified National Fine Thread) inlet connection and the flexible gas line provided.

WARNING: A qualified service person must con- nect fireplace to gas supply. Follow all local codes.

WARNING: Never connect natural gas fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: For natural gas, check gas line pressure before connecting fireplace to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.

CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This fireplace requires an external regulator (not supplied). Install the external regulator between the fireplace and pro- pane/LP supply.

For propane/LP units, the installer must supply an external regula- tor. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 29. Pointing the vent down protects it from freezing rain or sleet.

External Regulator

Propane/LP

Supply Tank

Vent Pointing Down

Figure 29 - External Regulator With Vent Pointing Down

For morevisit www..com

107032

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualSafety Information Table of ContentsVent-Free Compact Classic Hearth Fireplace Product IdentificationProduct Features Optional Remote Control AccessoriesLocal Codes UnpackingAssembling Fireplace AssemblyDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion and VentilationProviding Adequate Ventilation Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors InstallationCheck GAS Type Installation ItemsFireplace Clearances Minimum Clearance to Combustible MaterialsRough Opening for Installing in Wall BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Optional Mantel InstallationAssembling Brass Trim Brass trim shipped with mantel Removing Upper Louver Assembly and Branch SupportInstalling Blower Accessory Valve cover shield. see Figure For Built-In InstallationExtension Cord Removing Upper Louver AssemblyRemoving Valve Cover Shield Installing Blower AssemblyValve Cover Shield Switch PlateScrew Attaching Wood Base to Solid Floor Connecting to GAS SupplyInstallation Items Needed Connecting Equipment Shutoff Valve to Heater ControlChecking GAS Connections Pressure Testing gas Supply Piping systemInstalling Receiver Optional Wireless HAND-HELD Remote Control AccessoriesPressure Testing Fireplace Gas Connections Optional Wall Mounted Thermostat GWMT1 Installing 9-Volt Battery in Hand-Held Remote Control UnitBack View of Thermostat Base Installing LOG SET and ScreenLighting Instructions Operating FireplaceREMOTE-READY Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Turn OFF GAS to Appliance Thermostat Control OperationPropane/LPGasPilot Natural Gas Pilot GWMT1 Wall Mounted Thermostat Optional Optional Remote OperationThermostat Control Operation Ghrcta Series OperationInspecting Burners GWMS2 Wall Mounted Switch OptionalBurner Flame Pattern Pilot Flame PatternCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLOG SET CabinetObserved Problem Possible Cause Remedy TroubleshootingRemedy Observed Problem Possible CauseGas leak. See Warning statement Service Hints SpecificationsTechnical Service When Gas Pressure Is Too LowParts Under Warranty Replacement Parts Wiring DiagramParts not Under Warranty Remote-Ready Models OnlyTHERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNB Illustrated Parts BreakdownTHERMOSTAT-CONTROLLED Models Parts ListREMOTE-READY Models Parts List Accessories WALL-MOUNT Thermostat Switch GWMT1 Cleaning KIT GCKWALL-MOUNT ON/OFF Switch GWMS2 Receiver and HAND-HELD Remote Control KIT GhrcFor . .com Owners Registration Form Postage Required 107032 Limited Warranty VENT-FREE Compact Classic Hearth Fireplace Warranty Information

VMH10TPB specifications

Desa VMH10TPB is a cutting-edge heating solution designed for both residential and commercial applications. This innovative unit is known for its efficiency, advanced technology, and user-friendly features, making it a top choice for consumers looking for reliable heating options.

One of the standout features of the Desa VMH10TPB is its impressive heating capacity. With a maximum output of 10,000 BTUs, this unit is capable of heating spaces effectively, ensuring comfort during the colder months. It is particularly well-suited for areas up to 1,000 square feet, making it ideal for large living rooms, garages, or even small workshops.

The VMH10TPB incorporates advanced infrared heating technology, which provides a more efficient and effective heating experience compared to conventional heaters. Infrared heating warms objects and people directly, rather than just the air, resulting in immediate comfort without the need to wait for the room temperature to rise. This technology also means lower energy costs, as the unit operates at a higher efficiency rate.

Another key characteristic of the Desa VMH10TPB is its ease of use. The unit features a straightforward control panel that allows users to set their preferred temperature with precision. Additionally, it comes with a remote control, providing the convenience of adjusting settings from a distance. This feature is particularly beneficial for those who want to maintain control without having to get up repeatedly.

In terms of safety, the VMH10TPB is equipped with multiple safety features, including an automatic shut-off function and overheating protection. This ensures peace of mind for users, especially in households with children or pets. The durable construction of the unit also adds to its longevity, making it a wise investment for any property owner.

The sleek design of the Desa VMH10TPB allows it to blend seamlessly into various decor styles, whether modern or traditional. Its compact size makes it easy to install and relocate, providing flexibility in heating arrangements.

In conclusion, the Desa VMH10TPB is a powerful and efficient heating solution that combines advanced heating technology with user-friendly features and robust safety measures. With its high output capacity, infrared heating efficiency, and thoughtful design, it is a standout choice for anyone in need of reliable and effective heating.