6.Connect one bare wire end to each terminal (“W” and “R”) of the thermostat base (see Figure 43).

7.Install the base onto the wall with the provided screws.

8.Move the temperature adjustment back and forth to insure the bimetal is free from restrictions.

9.Replace the cover onto the base. (Upon installation, the ther- mostat must be allowed to stabilize at room temperature for a minimum of 30 minutes for proper operation).

10.Set switch on fireplace to Auto position.

11.Set the temperature adjustment to the desired setting. This ther- mostat has been electronically calibrated at the factory. No ad- justment or leveling is necessary.

Feed wires through rectangular slots

Figure 42 - Back View of Thermostat Base

Terminal “W”

W

Terminal “R”

R

WARNING: Do not connect this switch to any electrical source! Electrical shock and/or fire hazard will occur.

1.Connect one terminal of 25 ft. wire to bottom contact of switch (see Figure 41, page 21).

2.Connect remaining wire terminal to the “TH” terminal on the control valve. Make sure that wire terminals are in the posi- tions on your unit as pictured in Figure 41, page 21. If wires are not “crossed” the thermostat will not work.

3.Route the 25 ft. wire to a convenient location to mount your wall switch (no outside walls).

WARNING: Do not connect the switch to a power source. Electrical shock and/or fire hazard will occur.

IMPORTANT: The wire may be shortened but must not be lengthened.

4.Connect one bare wire end to each of the terminals of the pro- vided wall switch.

5.Install the wall switch and cover in the wall.

INSTALLING LOG SET AND SCREEN

1.Remove log packaging material and discard packaging. Gen- tly place log on burner support (see Figure 44). The log should fit flat against top of burner support and log locator tabs fit into the slots under the log. Do not allow log to contact flame. If flame contacts log, soot will be created.

2.Reattach screen by placing the notches in the screen frame over the shoulder screws and pushing down.

Shoulder Screw

Log

Figure 43 - Thermostat Base Terminals “W” and “R”

OPTIONAL WALL SWITCH - GWMS2 (Remote-Ready Models Only)

WARNING: Read and follow installation instruc- tions. Installation should be done by a qualified installer familiar with low-voltage wiring procedures.

Screen

Burner Support with

Log Locator Tabs

Figure 44 - Installing Log and Screen

For..com

107032

Image 22
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Vent-Free Compact Classic Hearth FireplaceLocal Codes Optional Remote Control AccessoriesProduct Features UnpackingAssembly Assembling FireplaceProviding Adequate Ventilation AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Ventilation Air From OutdoorsFireplace Clearances Installation ItemsCheck GAS Type Minimum Clearance to Combustible MaterialsBUILT-IN Fireplace Installation Rough Opening for Installing in WallOptional Mantel Installation Mantel Clearances for Built-In InstallationInstalling Blower Accessory Removing Upper Louver Assembly and Branch SupportAssembling Brass Trim Brass trim shipped with mantel For Built-In Installation Valve cover shield. see FigureRemoving Upper Louver Assembly Extension CordInstalling Blower Assembly Removing Valve Cover ShieldValve Cover Shield Switch PlateScrew Connecting to GAS Supply Attaching Wood Base to Solid FloorConnecting Equipment Shutoff Valve to Heater Control Installation Items NeededPressure Testing gas Supply Piping system Checking GAS ConnectionsPressure Testing Fireplace Gas Connections Optional Wireless HAND-HELD Remote Control AccessoriesInstalling Receiver Installing 9-Volt Battery in Hand-Held Remote Control Unit Optional Wall Mounted Thermostat GWMT1Installing LOG SET and Screen Back View of Thermostat BaseOperating Fireplace Lighting InstructionsTo Turn OFF GAS to Appliance Manual Lighting ProcedureREMOTE-READY Models For Your Safety Read Before Lighting Thermostat Control OperationPropane/LPGasPilot Natural Gas Pilot Thermostat Control Operation Optional Remote OperationGWMT1 Wall Mounted Thermostat Optional Ghrcta Series OperationBurner Flame Pattern GWMS2 Wall Mounted Switch OptionalInspecting Burners Pilot Flame PatternLOG SET Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole CabinetTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause RemedyGas leak. See Warning statement Technical Service SpecificationsService Hints When Gas Pressure Is Too LowParts not Under Warranty Replacement Parts Wiring DiagramParts Under Warranty Remote-Ready Models OnlyIllustrated Parts Breakdown THERMOSTAT-CONTROLLED Models VMH10TPB, VMH10TNBParts List THERMOSTAT-CONTROLLED ModelsREMOTE-READY Models Parts List Accessories WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKWALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Remote Control KIT GhrcFor . .com Owners Registration Form Postage Required 107032 Warranty Information Limited Warranty VENT-FREE Compact Classic Hearth Fireplace

VMH10TPB specifications

Desa VMH10TPB is a cutting-edge heating solution designed for both residential and commercial applications. This innovative unit is known for its efficiency, advanced technology, and user-friendly features, making it a top choice for consumers looking for reliable heating options.

One of the standout features of the Desa VMH10TPB is its impressive heating capacity. With a maximum output of 10,000 BTUs, this unit is capable of heating spaces effectively, ensuring comfort during the colder months. It is particularly well-suited for areas up to 1,000 square feet, making it ideal for large living rooms, garages, or even small workshops.

The VMH10TPB incorporates advanced infrared heating technology, which provides a more efficient and effective heating experience compared to conventional heaters. Infrared heating warms objects and people directly, rather than just the air, resulting in immediate comfort without the need to wait for the room temperature to rise. This technology also means lower energy costs, as the unit operates at a higher efficiency rate.

Another key characteristic of the Desa VMH10TPB is its ease of use. The unit features a straightforward control panel that allows users to set their preferred temperature with precision. Additionally, it comes with a remote control, providing the convenience of adjusting settings from a distance. This feature is particularly beneficial for those who want to maintain control without having to get up repeatedly.

In terms of safety, the VMH10TPB is equipped with multiple safety features, including an automatic shut-off function and overheating protection. This ensures peace of mind for users, especially in households with children or pets. The durable construction of the unit also adds to its longevity, making it a wise investment for any property owner.

The sleek design of the Desa VMH10TPB allows it to blend seamlessly into various decor styles, whether modern or traditional. Its compact size makes it easy to install and relocate, providing flexibility in heating arrangements.

In conclusion, the Desa VMH10TPB is a powerful and efficient heating solution that combines advanced heating technology with user-friendly features and robust safety measures. With its high output capacity, infrared heating efficiency, and thoughtful design, it is a standout choice for anyone in need of reliable and effective heating.