FMI GFI55 Installation, Safety Warnings & Recommendations, USE of Cordwood is Prohibited by LAW

Page 5

INSTALLATION

SAFETY WARNINGS & RECOMMENDATIONS

CAUTION:

Do not connect to any air distribution duct or system.

Do not burn garbage or flammable fluids such as gasoline, naptha or engine oil.

Unit hot while in operation. Keep children, clothing and fur- niture away. Contact may cause skin burns.

FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your dealer for fuel recommendations.

THE USE OF CORDWOOD IS PROHIBITED BY LAW.

SOOT: Operation of the stove with insuffi cient combustion air will result in the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is inefficient. Frequently check your stove and adjust the slider/damper as needed to ensure proper combustion. See "Slider/Damper Setting".

CLEANING: There will be some build up of fl y ash and small amounts of creosote in the exhaust. This will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi-annually or every two tons of pellets.

ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the closed container until all cinders have been thoroughly cooled.

ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 115 volts (4.6 Amps), 60 hertz electrical outlet. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacture or a qualifi ed Greenfi re dealer. This unit's maximum power requirement is 520 watts.

GLASS: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an Greenfire dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass.

FLAMMABLE LIQUIDS: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in the heater. Keep all such liquids well away from the heater while

it is in use.

SMOKE DETECTOR: Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning

appliance.

OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet stove. Also ensure all gaskets on the door are checked and replaced when necessary.

KEEP ASH PAN FREE OF RAW FUEL.

DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A FIRE IN THE ASH PAN MAY OCCUR.

INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING

ANOTHER APPLIANCE.

FRESH AIR: Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile and “Air Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion.

If you have any questions with regards to your stove or the above- mentioned information, please feel free to contact your local dealer for further clarification and comments.

SINCE FPI HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, FPI GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, FPI ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

INSTALLATION

Greenfi re Pellet Stove and Insert Owner's Manual

5

Image 5
Contents GF55 & GFI55 To the NEW Owner FPI Fireplace ProductTable of Contents Étiquettecette Pasretirez Safety LabelSafety Warnings & Recommendations InstallationUSE of Cordwood is Prohibited by LAW Keep ASH PAN Free of RAW FuelI. Pellet Standards Important Safety InformationPellet Quality Control Board Functions Automatic Safety FeaturesOperating Instructions High / LOW Mode Manual ModeAuto / OFF Mode Operating Your Pellet StoveSpecial Notes Slider / Damper Must be SET AT Time of InstallationSlider / Damper SET-UP Routine Cleaning & Maintenance MaintenanceHeat Exchanger Tubes ASH PANFresh AIR Intake Exhaust VentCleaning Plated Surfaces Exhaust Passages Post Season CLEAN-UPFirebox Panel Replacing Door GlassLimited Lifetime Warranty WarrantyExclusions and Limitations Warranty Installer Please complete the following information

GF55, GFI55 specifications

The FMI GF55 and GFI55 are two notable models in the world of high-performance power generation and distribution, catering to various industrial and commercial applications. Both models are designed with cutting-edge technology and engineering, making them reliable solutions for today's energy demands.

The FMI GF55 is a gas-powered generator offering high efficiency and low emissions. Designed for various uses, from construction sites to emergency backup power, this generator boasts a robust 55 kVA output. Its compact design allows for easy transportation and installation, making it a preferred choice for contractors and businesses needing portable power. The generator is equipped with a silent operation feature, ensuring minimal noise pollution, which is particularly advantageous in residential areas or sensitive environments.

On the other hand, the GFI55 model stands out for its advanced inverter technology. This technology enables stable power supply with minimal harmonic distortion, making it suitable for sensitive electronic equipment. The GFI55 is also built with durability in mind, using high-quality materials that ensure a longer lifespan and reduced maintenance needs. Its lightweight structure, combined with an easy-to-use interface, allows operators to quickly set up and utilize the generator.

In terms of connectivity, both models feature multiple output options, allowing users to connect various devices simultaneously. This versatility is a significant advantage for users who require power for multiple applications at once. Additionally, FMI prioritizes safety, equipping both the GF55 and GFI55 with various safety features such as overload protection and automatic shutdown to prevent damage during operational anomalies.

Both models incorporate fuel-efficient technologies that minimize running costs while maximizing performance. They are designed to comply with stringent environmental regulations, ensuring reduced carbon footprints for operations. This feature is growing in importance as industries increasingly pivot towards sustainable practices.

In conclusion, the FMI GF55 and GFI55 represent the best in power generation technology, combining efficiency, functionality, and safety in a compact design. Businesses and contractors looking for reliable, durable, and environmentally friendly power solutions will find these models effective and economical for their operational needs.