Vermont Casting 2465, 2466 manual Venting Termination Clearances, Location of Vent Termination

Page 9

Dutchwest Direct Vent / Natural Vent Gas Heater

Venting Termination Clearances

Your stove is approved to be vented either through the side wall, or vertical through the roof.

This unit does not require any opening for in- spection of vent pipe.

Only CFM Corporation and Simpson DuraVent venting components specifically approved and labelled for this stove may be used.

Minimum clearances between vent pipes and combustible materials is one (1”) inch (25 mm), except where stated otherwise.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting must be installed on a level plane without an inclining or declining slope.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observ- ing the minimum clearances as shown on this page.

30001935

9

Image 9
Contents Direct Vent / Natural Vent Gas Heater Table of Contents Verify proper operation after servicing General InformationDutchwest dimensions Dutchwest Direct Vent / Natural Vent DimensionsLocating the Stove Installation RequirementsWall Centerline from Floor Wall and Ceiling ClearancesHearth Requirements Gas Inlet and Manifold Pressures Gas SpecificationsHorizontal Termination Direct Vent only Input ModelVent Termination Clearances Vertical Termination Direct Vent onlyLocation of Vent Termination Venting Termination ClearancesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlyRemove rear skirt insert Install the Optional FanVenting System Assembly Direct Vent General Information Install the Vent Adapter PipeAttach the Inner Vent Assembly to the stove Simpson DuraVent install inner adapter pipe Side Wall Termination AssemblyDetermine the vertical pipe length Vent Termination Below Grade Vertical Through the Roof Vent AssemblyInstall the Vent Pipe Venting System Assembly Natural Vent General InformationConnect the Gas Supply Line Install the Log SetBurner Information Air Shutter AdjustmentInstall ON/OFF Switch Complete the AssemblyThermostat Connection optional Install the Stove FrontThermostat Maximum RunFlame Characteristics Flame & Temperature AdjustmentOperation Your First FireTo Turn Off Gas To Heater Lighting and Operating InstructionsSymptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemConversion Procedure Conversion PrecautionsFuel Conversion Instructions Honeywell ValvePilot Type Pilot Orifice ConversionInjector Orifice Size Matrix Maintenance Gasket Replacement Stove DisassemblyInspect the Vent System Annually Power Cord FAN Wiring Diagrams16a,b Description DutchwestFuel Conversion Kits Dutchwest Direct Vent / Natural Vent Gas HeaterRemote Controls Optional AccessoriesFan Kits Decorative RingsLimited Lifetime Warranty Model EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings

2466, 2465 specifications

Vermont Casting's 2465 and 2466 stoves are renowned in the world of wood-burning appliances, celebrated for their blend of traditional craftsmanship, modern technology, and efficient features. These stoves bring warmth and aesthetic appeal to any home while providing an eco-friendly heating solution.

The Vermont Casting 2465 model stands out with its classic styling and robust construction, made from high-quality cast iron. Its design not only provides durability but also enhances heat retention, allowing for longer-lasting warmth in your space. Featuring a large viewing window, the 2465 allows you to enjoy the mesmerizing flames while also providing ample heat output, making it a focal point of any room.

Similarly, the Vermont Casting 2466 shares many characteristics with its counterpart but introduces slightly elevated features. One of the notable features of the 2466 is its increased heating capacity, suitable for larger homes or open-concept living spaces. Both models are equipped with a user-friendly air control system that optimizes airflow and combustion, ensuring that wood burns more efficiently and cleanly. This results in minimal smoke emissions and contributes to a lower environmental impact.

One of the standout technologies in both the 2465 and 2466 is the patented “Dual Air Control” system. This innovative design allows homeowners to easily adjust the airflow for more efficient burning, regardless of the type of wood used, enhancing combustion efficiency. Users can start with a higher airflow for a quick fire start and then throttle back once the wood is burning well, ensuring an effective and adjustable burn rate.

Additionally, both models come with an integrated ash pan located at the bottom, designed to simplify maintenance by making ash removal quick and easy. The stoves also feature a built-in heat shield that helps to increase the heating efficiency of the stove while reducing the clearance needed for safe installation.

Overall, the Vermont Casting 2465 and 2466 stoves represent an intersection of function and beauty. Their classic cast iron design paired with modern heating technologies makes them a perfect choice for those wishing to combine traditional aesthetics with efficiency and environmental responsibility in their home heating solutions. Whether you're heating a cozy cabin or a spacious family room, these stoves deliver exceptional performance and timeless appeal.