Desa Tech CGN10TL installation manual Pilot

Page 17
C-clockwise
C-clockwise

OPERATING HEATER

Continued

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 16. If you don’t smell gas, go to the next step.

5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 15, page 16).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 21 through

24.Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 18.

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 16 - Pilot

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8. Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

CAUTION

WARNING ICON

G 001

Do not try to adjust heating levels by using the manual shutoff valve.

Continued 17

103574

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpacesDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsNever install the heater A bathroom A recreational vehicle Installation ItemsCheck GAS Type Locating HeaterMarking Screw Locations Installing Heater to WallThermostat Sensing Bulb Folding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot Shutting Off Burner Only pilot stays lit Shutting Off HeaterPilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice TROUBLE- Shooting Observed Possible Remedy Problem CauseCleaning and Mainte Top Ing statement atService Hints Technical ServiceBreakdown CGN10T CGN10TL Parts ListParts Under Warranty Service Publications AccessoryParts Not Under Warranty Valve GA5010Parts Central 103574 103574 Keep this Warranty Warranty Information

CGN10T, CGN10TL specifications

The Desa Tech CGN10T and CGN10TL are innovative indoor gas heaters designed to provide efficient, reliable, and comfortable heating solutions for residential spaces. Their advanced features, modern technology, and user-friendly characteristics make them standout options for homeowners looking to enhance their indoor heating experience.

One of the prominent features of the CGN10T and CGN10TL models is their high heating capacity. With a maximum output of up to 10,000 BTUs, these heaters are capable of warming rooms quickly and effectively, ensuring a cozy atmosphere even in the coldest months. Their quiet operation adds to their appeal, allowing users to enjoy warmth without the disruptive noise often associated with traditional heating systems.

The CGN10T model comes equipped with a manual ignition system, offering simplicity and ease of use. Meanwhile, the CGN10TL features a convenient electronic ignition system, providing added convenience for users. Both models include an adjustable thermostat, enabling individuals to set their desired temperature for personalized comfort.

Desa Tech has integrated advanced safety features into these heaters, making them ideal for indoor use. The units are equipped with an automatic shut-off mechanism that activates in the event of low oxygen levels detected in the room, ensuring peace of mind for users. Additionally, a built-in safety valve is designed to prevent gas leakage, further enhancing safety in home environments.

The sleek and compact design of the CGN10T and CGN10TL allows for easy placement in various room layouts. Their versatile styling means they can blend seamlessly with existing décor, while their lightweight construction enables effortless relocation when necessary.

Energy efficiency is another hallmark of the Desa Tech CGN10T and CGN10TL models. They employ advanced technologies that ensure optimal fuel consumption, helping users save on energy costs while reducing their carbon footprint. The heaters utilize a natural gas source, which is often more cost-effective compared to electric heating systems.

In conclusion, the Desa Tech CGN10T and CGN10TL gas heaters offer a perfect combination of performance, safety, and efficiency. With their high heating capacity, user-friendly features, and modern safety technologies, these models are an excellent choice for anyone looking to create a warm, comfortable living space during the chilly months.