Desa Tech CGN10TL AIR for Combustion and Ventilation, Providing Adequate Ventilation

Page 5

AIR FOR COMBUSTION AND VENTILATION

WARNING

WARNING ICON

G 001

This heater shall not be installed in a confined space unless provisions are provided for adequate combustion and ventilation air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy efficient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PROVIDING ADEQUATE VENTILATION

The following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Contruction; 2. Unconfined Space; 3. Confined Space.

The information on pages 5 through 8 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the outside atmosphere have a continu- ous water vapor retarder with a rating of one perm (6x10-11per pa-sec- m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide addi- tional fresh air. See Ventilation Air From Outdoors, page 8.

If your home does not meet all of the three criteria above, proceed to page 6.

Confined and Unconfined Spaces

The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1000 Btu per hour (4.8 cubic meters per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1000 Btu per hour (4.8 cubic meters per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space.

Continued 5

103574

Image 5
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualContents Safety Information Safety Device Local Codes Unpacking Product FeaturesProduct Identification Piezo Ignition SystemProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpacesDetermining if You Have a Confined or Unconfined Space Determining AIR Flow for Heater LocationVentilation Air From Inside Building Ventilation AIRVentilation Air from Outdoors Ventilation Air From OutdoorsNever install the heater A bathroom A recreational vehicle Installation ItemsCheck GAS Type Locating HeaterMarking Screw Locations Installing Heater to WallThermostat Sensing Bulb Folding Anchor Installing Two Mounting ScrewsPlacing Heater On Mounting Screws Connecting to GAS Supply Pressure Testing GAS Supply Piping System Connecting to GAS Supply Checking GAS ConnectionsManual Shutoff Valve Pressure Testing Heater GAS ConnectionsOperating Heater For Your Safety Read Before LightingPilot Shutting Off Burner Only pilot stays lit Shutting Off HeaterPilot Flame Pattern Inspecting BurnerCorrect Burner Flame Pattern Burner Flame PatternCabinet Cleaning and Maintenance Trouble ShootingODS/PILOT and Burner Orifice TROUBLE- Shooting Observed Possible Remedy Problem CauseCleaning and Mainte Top Ing statement atService Hints Technical ServiceBreakdown CGN10T CGN10TL Parts ListParts Under Warranty Service Publications AccessoryParts Not Under Warranty Valve GA5010Parts Central 103574 103574 Keep this Warranty Warranty Information

CGN10T, CGN10TL specifications

The Desa Tech CGN10T and CGN10TL are innovative indoor gas heaters designed to provide efficient, reliable, and comfortable heating solutions for residential spaces. Their advanced features, modern technology, and user-friendly characteristics make them standout options for homeowners looking to enhance their indoor heating experience.

One of the prominent features of the CGN10T and CGN10TL models is their high heating capacity. With a maximum output of up to 10,000 BTUs, these heaters are capable of warming rooms quickly and effectively, ensuring a cozy atmosphere even in the coldest months. Their quiet operation adds to their appeal, allowing users to enjoy warmth without the disruptive noise often associated with traditional heating systems.

The CGN10T model comes equipped with a manual ignition system, offering simplicity and ease of use. Meanwhile, the CGN10TL features a convenient electronic ignition system, providing added convenience for users. Both models include an adjustable thermostat, enabling individuals to set their desired temperature for personalized comfort.

Desa Tech has integrated advanced safety features into these heaters, making them ideal for indoor use. The units are equipped with an automatic shut-off mechanism that activates in the event of low oxygen levels detected in the room, ensuring peace of mind for users. Additionally, a built-in safety valve is designed to prevent gas leakage, further enhancing safety in home environments.

The sleek and compact design of the CGN10T and CGN10TL allows for easy placement in various room layouts. Their versatile styling means they can blend seamlessly with existing décor, while their lightweight construction enables effortless relocation when necessary.

Energy efficiency is another hallmark of the Desa Tech CGN10T and CGN10TL models. They employ advanced technologies that ensure optimal fuel consumption, helping users save on energy costs while reducing their carbon footprint. The heaters utilize a natural gas source, which is often more cost-effective compared to electric heating systems.

In conclusion, the Desa Tech CGN10T and CGN10TL gas heaters offer a perfect combination of performance, safety, and efficiency. With their high heating capacity, user-friendly features, and modern safety technologies, these models are an excellent choice for anyone looking to create a warm, comfortable living space during the chilly months.