Desa Tech S26NTA, S26PTA installation manual Heater produces a whistling

Page 20

TROUBLESHOOTING

 

 

Continued

 

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a whistling

1. Turning control knob to HI po-

1.

Turn control knob to LO po-

noise when burner is lit

 

sition when burner is cold

 

sition and let warm up for a

 

 

 

 

minute

 

2.

Air in gas line

2.

Operate burner until air is re-

 

 

 

 

moved from line. Have gas line

 

 

 

 

checked by local gas company

 

3.

Air passageways on heater

3.

Observe minimum installation

 

 

blocked

 

clearances (see page 8)

 

4.

Dirty or partially clogged

4.

Clean burner (see Cleaning and

 

 

burner orifice

 

Maintenance, pages 16 and 17)

 

 

 

 

or replace burner orifice

Dark residue on logs or inside of 1. Improper log placement fireplace

2. Drafts or other air currents af- fecting flame pattern

3. Air holes at burner inlet blocked

4. Burner flame holes blocked

1.Properly locate logs (see In- stalling Logs, pages 11 and 12)

2.Eliminate source of drafts around heater

3.Clean out air holes at burner inlet. Periodically repeat as needed

4.Remove blockage or replace burner

White powder residue forming within burner box or on adja- cent walls or furniture

1.When heated, vapors from fur- niture polish, wax, carpet cleaners, etc. may turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Heater produces a clicking/tick- ing noise just after burner is lit or shut off

1.Metal expanding while heating or contracting while cooling

1.This is common with most heat- ers. If noise is excessive, con- tact qualified service person

20

www.desatech.com

110361-01E

Image 20
Contents What to do if YOU Smell GAS Thermostatically Controlled Models S26PTA and S26NTATable of Contents Safety Information Product Identification Vent-Free Freestanding Pedestal StoveProduct Features Local CodesUnpacking AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Installation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Wall and Ceiling Clearances see Figure Check GAS TypeClearances to Combustibles Connecting to GAS Supply Installation Items NeededPressure Testing Gas Supply Piping System Checking GAS ConnectionsPropane/LP NaturalInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Blower Accessory GA3750 Installing One-Piece Log set Top ViewInstalling Blower Control Housing Lighting Instructions For Your Safety Read Before LightingOperating Heater Inspecting Burners Cleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleSpecifications Service HintsTechnical Service Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Heater produces a whistling Gas leak. See Warning Statement aboveIllustrated Parts Breakdown Parts List Models S26PTA and S26NTA KEY Description QTY Replacement Parts AccessoriesParts Central Limited Warranty VENT-FREE GAS Pedestal Stove Warranty InformationKeep this Warranty

S26NTA, S26PTA specifications

Desa Tech has been making significant strides in the world of wireless communication, particularly with their offerings of the S26PTA and S26NTA models. These cutting-edge devices are designed to meet the growing demands for high-performance connectivity in various applications.

The S26PTA model is a powerhouse of capabilities, particularly suited for industries requiring reliable data transmission. Its main feature includes an impressive range, allowing it to cover vast distances while maintaining a robust connection. The S26PTA employs advanced signal processing algorithms which enhance its performance in challenging environments, ensuring minimal interference and optimal data integrity. This makes it ideal for applications that require consistent connectivity, such as in remote monitoring systems or industrial automation.

On the other hand, the S26NTA focuses on versatility and ease of integration. It comes equipped with multiple connectivity options, supporting both wired and wireless protocols. This flexibility allows businesses to seamlessly adapt the device to their existing infrastructure without the need for significant modifications. Furthermore, the S26NTA is designed with energy efficiency in mind, which is crucial for applications where power consumption is a concern, such as in IoT devices.

Both models integrate state-of-the-art security features to protect sensitive data. With end-to-end encryption and robust authentication protocols, Desa Tech ensures that users can trust the integrity of their communications. This is particularly significant in fields that handle confidential information, as it mitigates the risk of unauthorized access and data breaches.

In terms of user experience, both the S26PTA and S26NTA are designed with intuitive interfaces and straightforward setup processes. This user-centric design philosophy reduces the technical barrier for businesses looking to implement advanced communication technologies. Furthermore, regular software updates are provided to enhance functionality and ensure that users benefit from the latest technological advancements.

In summary, the Desa Tech S26PTA and S26NTA devices exemplify the future of wireless communication technology. With their advanced features, robust security measures, and user-friendly designs, they are well-equipped to handle the demands of modern applications. Whether for industrial automation, IoT, or other communication needs, these models offer reliable and efficient solutions that stand out in the competitive tech landscape.