Desa Tech S26PTA, S26NTA installation manual Service Hints, Technical Service, Specifications

Page 17

CLEANING AND

MAINTENANCE

Continued

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust.

LOGS

If you remove logs for cleaning, refer to In- stalling Logs, pages 11 and 12, to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

propane/LP gas supply may be low

You may feel your gas pressure is too low. If so, contact your local gas supplier.

TECHNICAL SERVICE

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Heating Products’ Technical Service Department at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ tech- nical services web site at www.desatech.com.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage. Blocked burner flame holes will create soot.

SPECIFICATIONS

 

S26PTA

S26NTA

Btu (Variable)

20,000/26,000

20,000/26,000

Type Gas

Propane/LP Only

Natural Only

Ignition

Piezo

Piezo

Manifold Pressure

8" W.C.

3.0" W.C.

Inlet Gas Pressure (in. of water) *

 

Maximum

14"

10.5"

Minimum

11"

5"

Dimensions, Inches (H x W x D)

 

Stove

24 x 27 1/4 x 17 1/4

24 x 27 1/4 x 17 1/4

Carton

22 x 31 x 31 1/2

22 x 31 x 31 1/2

Weight, pounds

 

 

Stove

66 lbs.

66 lbs.

Shipping

80 lbs.

80 lbs.

* For purposes of input adjustment

110361-01E

www.desatech.com

17

Image 17
Contents Thermostatically Controlled Models S26PTA and S26NTA What to do if YOU Smell GASTable of Contents Safety Information Vent-Free Freestanding Pedestal Stove Product IdentificationLocal Codes Product FeaturesUnpacking AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation AIR InstallationVentilation Air From Inside Building Ventilation Air From OutdoorsMinimum Wall and Ceiling Clearances see Figure Check GAS TypeClearances to Combustibles Installation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPropane/LP NaturalPressure Testing Heater Gas Connections Installing LogsInstalling One-Piece Log set Top View Installing Blower Accessory GA3750Installing Blower Control Housing Lighting Instructions For Your Safety Read Before LightingOperating Heater Inspecting Burners Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceSpecifications Service HintsTechnical Service Observed Problem Possible Cause Remedy TroubleshootingSee Cleaning and Mainte Heater produces a whistling Statement above Gas leak. See WarningIllustrated Parts Breakdown Parts List Models S26PTA and S26NTA KEY Description QTY Accessories Replacement PartsParts Central Limited Warranty VENT-FREE GAS Pedestal Stove Warranty InformationKeep this Warranty

S26NTA, S26PTA specifications

Desa Tech has been making significant strides in the world of wireless communication, particularly with their offerings of the S26PTA and S26NTA models. These cutting-edge devices are designed to meet the growing demands for high-performance connectivity in various applications.

The S26PTA model is a powerhouse of capabilities, particularly suited for industries requiring reliable data transmission. Its main feature includes an impressive range, allowing it to cover vast distances while maintaining a robust connection. The S26PTA employs advanced signal processing algorithms which enhance its performance in challenging environments, ensuring minimal interference and optimal data integrity. This makes it ideal for applications that require consistent connectivity, such as in remote monitoring systems or industrial automation.

On the other hand, the S26NTA focuses on versatility and ease of integration. It comes equipped with multiple connectivity options, supporting both wired and wireless protocols. This flexibility allows businesses to seamlessly adapt the device to their existing infrastructure without the need for significant modifications. Furthermore, the S26NTA is designed with energy efficiency in mind, which is crucial for applications where power consumption is a concern, such as in IoT devices.

Both models integrate state-of-the-art security features to protect sensitive data. With end-to-end encryption and robust authentication protocols, Desa Tech ensures that users can trust the integrity of their communications. This is particularly significant in fields that handle confidential information, as it mitigates the risk of unauthorized access and data breaches.

In terms of user experience, both the S26PTA and S26NTA are designed with intuitive interfaces and straightforward setup processes. This user-centric design philosophy reduces the technical barrier for businesses looking to implement advanced communication technologies. Furthermore, regular software updates are provided to enhance functionality and ensure that users benefit from the latest technological advancements.

In summary, the Desa Tech S26PTA and S26NTA devices exemplify the future of wireless communication technology. With their advanced features, robust security measures, and user-friendly designs, they are well-equipped to handle the demands of modern applications. Whether for industrial automation, IoT, or other communication needs, these models offer reliable and efficient solutions that stand out in the competitive tech landscape.