Enviro EG40-070 owner manual Trouble Shooting, Problem Possible Cause Solution

Page 30

Trouble Shooting

Problem

Possible Cause

Solution

 

 

 

The main burner does not

The gas valve may not be on.

• Check that the gas control knob is in the “ON” position.

ignite when called for.

 

 

Thermostat is not calling for

• Adjust the thermostat several degrees above ambient

 

 

heat.

temperature.

 

 

 

 

Problem with gas valve.

• Use a DC voltmeter to measure the voltage across the

 

 

TPTH and TP terminals. Main operator voltage: Open

 

 

circuit ≥ 325mV Closed circuit ≥ 100mV

 

 

• If voltage is not present, check the control circuit for

 

 

proper operation.

 

 

• If proper control system voltage is present, replace the

 

 

gas control.

 

 

 

Spark will not light the pilot

Defective piezo ignitor.

• Check connections to ignitor.

after repeatedly pressing the

 

• If ignitor connections are good but no spark, replace

spark ignitor.

 

ignitor.

 

 

 

 

Broken spark electrode.

• Check for broken ceramic insulation, replace electrode if

 

 

broken.

 

 

 

 

Misaligned spark electrode.

• If spark is not arcing from electrode to pilot, loosen the

 

 

screws on the pilot base adjust and tighten.

 

 

 

Pilot will not remain lit.

Problem with thermocouple

• Check for proper connection of the thermocouple to the

 

circuit.

rear of the valve. If loose, fully tighten.

 

 

• Check pilot for full flame impingement around

 

 

thermocouple. If flame is too small, check gas pressure,

 

 

adjust pilot rate screw, check pilot head for damage.

 

 

• Check thermocouple voltage at valve. It must be greater

 

 

than 5 mV. If low, replace thermocouple.

 

 

 

 

Air in gas line (pilot dies while

• Bleed line.

 

knob is depressed).

• Check gas line pressure.

 

 

• Contact dealer.

 

 

 

Burners will not remain lit.

Problem with thermopile

• Check gas line pressure .

 

circuit.

• Check for flame impingement on thermopile. If low, see

 

 

“Pilot will not remain lit”.

 

 

• Check thermopile for minimum of 300 mV when burner is

 

 

switched on.

 

 

• Check wiring to thermostat for breaks.

 

 

 

Flame lifting

Leak in vent pipe

• Check for leaks in vent connections.

 

 

 

 

Improper vent configuration

• Check vent configuration with manual.

 

 

 

 

Terminal may be recirculating

• Check to see if terminal is on correctly.

 

flue gases

• May need to install high wind termination cap.

 

 

• Contact dealer.

 

 

 

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

 

**Due to additives in gas, glass may get hazy during operation** Clean as needed.

 

 

 

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

 

 

 

Flames are burning “dirty” or

Flame impingement

• Check log positioning.

sooting

 

• Increase primary air by opening the venturi shutter and/

 

 

or by opening the vent restrictor.

 

 

See also “Burners will not remain lit.”

 

 

 

Remote control doesn’t work

Problem with the remote

• One or more of the batteries are dead. See remote

 

 

control instructions.

 

 

 

 

Problem with fireplace

• The on/off switch is turned to OFF.

 

 

• The gas control valve is turned to PILOT or OFF.

 

 

• The pilot has gone out.

 

 

 

30

Image 30
Contents EG40 DV Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater EG40 DV NG/LPGSpecifications EG40 Exterior DimensionsFor Your Safety Read Completely Before Operating Operating InstructionsThere is a separate venturies for each burner, see Figure Component Sound & ReasonMaintenance and Service Removing the DoorBurner is lined up Kit Parts List Conversion Kit InstallationMust be not visible Removing valve ScrewInitial Installation Qualified Installers onlyCommon Vertical Installation Do not interfere with the structural integrity of the walls Vent Termination Restrictions KIT Components Installation of Fireplace Horizontal Vent Kit Manufacturer Trade Name Nominal Sizes4DSC Vent restrictor ring End of the pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand-Off Assemble the desired lengths of black pipe Use of Wall Straps Multi-Story Vent Pipe Installation Insulation33a-2002 Test Methods and the Resulting ITS/WH Must be connected to a grounding rod Must be bolted securely to the floorManifold Pressure Natural Gas Propane Front BurnerRear Burner Min. Manifold PressureSecondary Installation Log PlacementRemove door to clean glass Trouble Shooting Problem Possible Cause SolutionParts List T. Nova Valve Convertible 50-1421Parts List Parts Diagram Chassis Parts Diagram Gas Tray Door Warranty To the DistributorInstallation Data Sheet

EG40-070 specifications

The Enviro EG40-070 is a state-of-the-art outdoor wood-burning furnace designed to provide an efficient and eco-friendly heating solution for residential and commercial spaces. As homeowners increasingly seek sustainable alternatives to traditional heating methods, the EG40-070 emerges as a formidable contender in the market.

One of the standout features of the Enviro EG40-070 is its high-efficiency heating capability. With an impressive thermal efficiency rating, this furnace ensures that a significant portion of the heat generated from the burning wood is effectively transferred to the water that circulates throughout the heating system. This efficiency reduces the amount of wood needed for heating, making it an environmentally friendly option.

The furnace is equipped with a robust and durable construction, designed to withstand the rigors of outdoor use. The heavy-duty steel body is resistant to corrosion and wear, ensuring longevity and minimal maintenance. Additionally, the large firebox allows for extended burn times, which means users can load it with wood and enjoy consistent heating for hours without the need for constant refueling.

Another significant characteristic of the Enviro EG40-070 is its advanced combustion technology. It features a secondary combustion system that maximizes the efficiency of the fuel being burned. By allowing for the recirculation of exhaust gases, this system ensures that virtually all the combustible materials are utilized, resulting in cleaner emissions. This not only benefits the environment but also contributes to better air quality.

The Enviro EG40-070 also boasts a user-friendly design, complete with easy-access doors for loading fuel and cleaning. The integrated digital control system allows for precise regulation of the temperature and heat output, providing users with a customizable heating experience. Furthermore, the unit is compatible with various heating systems, including forced air and hydronic systems, making it versatile for different applications.

For safety, the furnace incorporates several safety features, including low water protection and an automatic shut-off function. These features are crucial in preventing overheating and ensuring safe operation, giving homeowners peace of mind.

In summary, the Enviro EG40-070 is a powerful outdoor wood-burning furnace that combines efficiency, durability, and functionality. Its advanced combustion technologies and user-friendly design make it a suitable choice for those looking to embrace a sustainable heating solution without compromising on performance or safety.