Enviro C-11288 owner manual Focus

Page 1

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

FOCUS

B Y : S H E R W O O D I N D U S T R I E S LT D

OWNER’S MANUAL

INSTALLER:

Leave this manual with the appliance.

CONSUMER:

Retain this manual for future reference.

WHAT TO DO IF YOU SMELL GAS

Open windows/extinguish any open flame.

Do not try to light any appliance.

Do not touch any electrical switch or use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This appliance is

only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use

with other gases,

unless a certified kit

is used.

Massachusetts installations (Warning): This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Other Massachusetts code requirements: Flexible connector must not be longer than 36in., a shut off valve must be installed; only direct vent sealed combustion products are approved for bedrooms/ bathrooms. A carbon monoxide detector is required in all rooms containing gas fired direct vent appliances. The fireplace damper must be removed or welded in the open position prior to installation of a fireplace insert.

EG31-118

Image 1
Contents Focus General Safety PrecautionsTable of Contents This Enviro Focus Fireplace Codes And ApprovalsDimensions SpecificationsOperating Instructions For Your Safety Read Before OperatingComponent Sound & Reason Natural Gas Propane Venturi Setting RearTop bolts for glass door Maintenance And ServiceEnsuring that wires and gas lines are Conversion Kit Installation Kit Parts ListWay, and snap into place Removing valve Screw Minimum fireplace size Width 34 86.36 cm Height 21 53.3 cm Initial InstallationQualified Installers only Installation of Leveling Legs Option 2 Standard Surround Panel Surround Panel installationConverting To a BV Fireplace Parts required for conversionVenting Fireplace Inserts Electrical Requirements To Test Valve Pressures Gas Line ConnectionFocus burner Secondary InstallationBrick Panel Installation Problem Possible Cause Solution Trouble ShootingReference Number Part Description Part Number Parts List ComponentsParts List Components Body Reference Number Part Description Part Number Parts List Surrounds & FasciaParts Diagram Surrounds & Fascia Parts List Cast Parts List Cast Parts Diagram- Cast Bay Front To the Dealer WarrantyWarranty Warranty Installation Data Sheet

C-11288 specifications

Enviro C-11288 is an innovative product that has garnered attention in the environmental technology sector. Primarily designed for sustainability initiatives, this advanced solution integrates a range of features and technologies that address the pressing concerns of waste management and resource conservation.

One of the standout features of Enviro C-11288 is its efficient waste processing capability. Utilizing state-of-the-art waste conversion technologies, it can transform organic and inorganic materials into reusable resources, effectively minimizing landfill use. The incorporation of advanced sorting algorithms ensures that the separation of recyclable materials is efficient and precise, enhancing the overall recycling process.

In addition to waste processing, the Enviro C-11288 is equipped with energy recovery systems. These systems capture and convert waste heat generated during processing into usable energy. This not only energy-optimizes the operation but also contributes to a lower carbon footprint, making it an environmentally friendly solution.

Another significant characteristic of the Enviro C-11288 is its scalability. Whether in a small community or a large industrial setup, the unit can be adapted to meet varying demands. This flexibility is further enhanced by modular design features, allowing users to expand or contract the system as needed without significant interruptions to their operations.

The technology behind Enviro C-11288 is also notable. Real-time monitoring and analytics capabilities enable users to track efficiency metrics, waste reduction rates, and energy consumption. This data-driven approach empowers organizations to make informed decisions about resource management and further improvements.

Durability and low maintenance are additional advantages provided by Enviro C-11288. Constructed with high-quality materials, the system is designed for longevity and can withstand harsh operational conditions. Low maintenance requirements translate into cost savings over time, further appealing to organizations with budget constraints.

Overall, Enviro C-11288 represents a significant advancement in environmental technology solutions. Its combination of waste management efficiency, energy recovery, scalability, real-time monitoring, and durable design positions it as a vital tool for organizations striving to implement sustainable practices while optimizing resource use. As industries continue to emphasize sustainability, the Enviro C-11288 offers a comprehensive solution that aligns with this critical goal.