Enviro C-11288 owner manual Kit Parts List, Conversion Kit Installation, Way, and snap into place

Page 10

Maintenance And Service

FUEL CONVERSION:

TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY

Please read and understand these instructions before installing.

Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.

Kit Parts List:

1 - Orifice (NG #38 DMS or LP #52 DMS)

1 - Pilot Injector (NG 0.62 mm; LP 0.35 mm)

1 - Installation instruction sheet

1 - Conversion label

Carefully inspect all parts supplied with this conversion kit. If any parts have been damaged or are missing, contact your dealer, distributor or courier company to have them replaced before starting this installation.

Conversion Kit Installation:

1.Turn control knob on the gas valve to the “OFF” position and shut the gas supply off at the shut-off valve upstream of the unit. CAUTION: The gas supply must be shut off prior to disconnecting the electrical power and before proceeding with the conversion. Allow the valve and unit to cool down to room temperature.

2.Remove the glass as shown in the MAINTENANCE AND SERVICE - OPENING THE DOOR.

3.Carefully remove the log set and ember material if they are installed.

4.Remove the burner as shown in the MAINTENANCE AND SERVICE - BURNER REMOVAL.

5.Convert the burner orifice(s):

a)Remove the main burner orifice with a 1⁄2 inch deep socket.

b)Put a bead of pipe-thread sealant or approved Teflon tape on the orifice threads before installing into the brass elbow.

c)Install the new orifice(s) from the kit into the brass elbow.

6.Convert the pilot injector:

a)Pull the pilot hood straight up to access the pilot injector.

b)Using a 5/32” or 4 mm Allen key, remove the pilot injector.

c)Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood using the Allen key,

d)Reinstall the hood by placing the hood on the assembly, line up the key

way, and snap into place.

 

Figure 8: Removing

 

 

valve cap.

10

Image 10
Contents Focus Safety Precautions GeneralTable of Contents Codes And Approvals This Enviro Focus FireplaceSpecifications DimensionsFor Your Safety Read Before Operating Operating InstructionsNatural Gas Propane Venturi Setting Rear Component Sound & ReasonMaintenance And Service Top bolts for glass doorEnsuring that wires and gas lines are Conversion Kit Installation Kit Parts ListWay, and snap into place Removing valve Screw Initial Installation Minimum fireplace size Width 34 86.36 cm Height 21 53.3 cmQualified Installers only Installation of Leveling Legs Surround Panel installation Option 2 Standard Surround PanelParts required for conversion Converting To a BV FireplaceVenting Fireplace Inserts Electrical Requirements Gas Line Connection To Test Valve PressuresSecondary Installation Focus burnerBrick Panel Installation Trouble Shooting Problem Possible Cause SolutionParts List Components Reference Number Part Description Part NumberParts List Components Body Parts List Surrounds & Fascia Reference Number Part Description Part NumberParts Diagram Surrounds & Fascia Parts List Cast Parts List Cast Parts Diagram- Cast Bay Front Warranty To the DealerWarranty Warranty Installation Data Sheet

C-11288 specifications

Enviro C-11288 is an innovative product that has garnered attention in the environmental technology sector. Primarily designed for sustainability initiatives, this advanced solution integrates a range of features and technologies that address the pressing concerns of waste management and resource conservation.

One of the standout features of Enviro C-11288 is its efficient waste processing capability. Utilizing state-of-the-art waste conversion technologies, it can transform organic and inorganic materials into reusable resources, effectively minimizing landfill use. The incorporation of advanced sorting algorithms ensures that the separation of recyclable materials is efficient and precise, enhancing the overall recycling process.

In addition to waste processing, the Enviro C-11288 is equipped with energy recovery systems. These systems capture and convert waste heat generated during processing into usable energy. This not only energy-optimizes the operation but also contributes to a lower carbon footprint, making it an environmentally friendly solution.

Another significant characteristic of the Enviro C-11288 is its scalability. Whether in a small community or a large industrial setup, the unit can be adapted to meet varying demands. This flexibility is further enhanced by modular design features, allowing users to expand or contract the system as needed without significant interruptions to their operations.

The technology behind Enviro C-11288 is also notable. Real-time monitoring and analytics capabilities enable users to track efficiency metrics, waste reduction rates, and energy consumption. This data-driven approach empowers organizations to make informed decisions about resource management and further improvements.

Durability and low maintenance are additional advantages provided by Enviro C-11288. Constructed with high-quality materials, the system is designed for longevity and can withstand harsh operational conditions. Low maintenance requirements translate into cost savings over time, further appealing to organizations with budget constraints.

Overall, Enviro C-11288 represents a significant advancement in environmental technology solutions. Its combination of waste management efficiency, energy recovery, scalability, real-time monitoring, and durable design positions it as a vital tool for organizations striving to implement sustainable practices while optimizing resource use. As industries continue to emphasize sustainability, the Enviro C-11288 offers a comprehensive solution that aligns with this critical goal.