INSTALLATION

D.VERTICALLY INTO EXISTING MASONRY FIREPLACE

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1.Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition.

2.You will need a pipe length equal to the chimney height from the hearth. If outside combustion air is to be used, you will need a pipe length equal to the chimney height plus 18 inches.

3.Install a blanking plate and the chimney pipe, and if used the outside air pipe, as shown in Figure 11.

4.Attach the L-Vent adapter, a section of pipe and clean out tee, making sure the clean out tee is centered in the chimney flue area. Use RTV, metallic tape, and a minimum of three self-taping screws at all joint connections to ensure a tight seal.

5.Position the stove, adhering to the clearances in Figures 1 & 2.

6.Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe. Install and seal with non-hardening mastic to prevent water leakage. Install vent cap.

E.INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY

NOTE: Follow L-Vent chimney manufacturer’s instructions.

1.Position the stove, adhering to the clearances in Figures 1 & 2. Mark the center of the hole where the pipe is to pierce the masonry chimney.

2.It will be necessary to break out the masonry around the location of the pipe center mark. Use a 4-inch diameter hole for 3-inch pipe and 5-inch diameter hole for 4-inch pipe.

3.Measure and build chimney top plate. Cut out holes for chimney pipe, and if used the outside air pipe.

4.Install the tee on the bottom of the vertical pipe system and lower it down the chimney until the center branch of the tee is level with the center of the hole in the masonry, as shown in Figure 12.

5.Install and seal the top plate from step 3 with non- hardening mastic. Slip the storm collar over the pipe, and while holding the pipe at the proper elevation, affix the collar with a minimum of three ¼” stainless steel sheet metal screws. Seal all joints and seams around the collar.

6.Connect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee. Push the pipe into the tee while twisting it to lock it into the tee.

7.If desired, once the horizontal pipe is in place, the space between the pipe and masonry may be filled with high-temperature grout.

8.Install the trim collar. An adjustable pipe length and adapter may be needed to finish the connection to the stove.

FIGURE 11

FIGURE 12

Image 10
Contents Tradition Series P24 Mail Your Warranty Card Today IntroductionSafety Precautions Table of Contents Preparation InstallationSpecifications Sidewall Clearances Alcove Clearances Floor ProtectionVenting When Outside AIR is not UsedCombustion AIR Supply Rear View P24FSA Rear View P24I Freestanding Installation Equivalent Vent Length EVLVertically with NEW Chimney System Refer to a & 9b Vertically Into Existing Chimney System Installation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP AS a BUILT-IN Fireplace Electrical Installation Special Mobile Home Requirements Installation in to a Factory Built Metal FireplaceOperation Building a Fire Proper FuelPRE-START-UP Check Hotrod Automatic FirestarterSafety Features Breckwell Maintenance ToolShutdown Procedure RE-STARTING a Warm StoveOptional Thermostat Thermostat InstallationThermostat Installation ∙ a Millivolt Thermostat is RequiredPlease Read this ASH Disposal Freestanding Models MaintenanceASH Removal ASH Disposal InsertBlowers CleaningVacuum USE Rear View P24FSRemoval and Replacement of Broken Door Glass Chimney CleaningRecommended Maintenance Schedule Daily Weekly Annually or per TonMaintenance Stove Shuts OFF and the # 2 Light Flashes Troubleshooting GuidePossible Causes Stove Shuts OFF and the # 3 Light Flashes Smoke Smell Coming Back Into the Home Stove Feeds PELLETS, but will not IgnitePossible Causes Possible Remedies Convection Blower Shuts OFF and Comes Back onTroubleshooting Guide Troubleshooting Guide Smoke Smell or Soot BUILD-UP High Limit Switch Keeps TrippingHeat Level Setting P24 Digital Circuit Board Timing RatesElectrical Diagram Replacement Parts BurnpotLifetime Limited Warranty