Breckwell P24I Proper Fuel, PRE-START-UP Check, Building a Fire, Hotrod Automatic Firestarter

Page 16

16

OPERATION

PROPER FUEL

THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void all warranties. The design incorporates automatic feed of the pellet fuel into the fire at a carefully prescribed rate. Any additional fuel introduced by hand will not increase heat output but may seriously impair the stoves performance by generating considerable smoke. Do not burn wet pellets. The stove’s performance depends heavily on the quality of your pellet fuel.

Avoid pellet brands that display these characteristics:

a.Excess Fines – “Fines” is a term describing crushed pellets or loose material that looks like sawdust or sand. Pellets can be screened before being placed in hopper to remove most fines.

b.Binders – Some pellets are produced with materials to hold them together, or “bind” them.

c.High ash content – Poor quality pellets will often create smoke and dirty glass. They will create a need for more frequent maintenance. You will have to empty the burnpot plus vacuum the entire system more often. Poor quality pellets could damage the auger. Breckwell cannot accept responsibility for damage due to poor quality pellets. Your dealer can recommend a good quality pellet dealer in your area.

PRE-START-UP CHECK

Remove optional imitation log set if in use. Remove burnpot, making sure it is clean and none of the air holes are plugged. Clean the firebox, and then reinstall burnpot. Clean door glass if necessary (a dry cloth or paper towel is usually sufficient). Never use abrasive cleaners on the glass or door. Check fuel in the hopper, and refill if necessary.

NOTE: The P24FS Hopper can hold up to 60 lbs. of pellets, and the P24I Hopper can hold up to 70 lbs.

BUILDING A FIRE

Never use a grate or other means of supporting the fuel. Use only the Breckwell approved burnpot.

During the start up period:

1)DO NOT open the viewing door.

2)DO NOT open the damper more than ¾”.

3)DO NOT add pellets to the burnpot by hand.

4)DO NOT use the Fuel Feed button (unless you are priming the auger after running out of pellets). A dangerous condition could result.

NOTE: During the first few fires, your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal. Maintaining smaller fires will minimize this. Avoid placing items on stovetop during this period because paint could be affected.

THE HOTROD AUTOMATIC FIRESTARTER

a.Fill hopper and clean burnpot.

b.Press “On/Off” button. Make sure light is on.

c.Adjust damper to ½” to ¾” open (pushed in is closed). This will vary depending on your installation and elevation. Once fire is established adjust for desired flame increasing the amount the damper is open as the heat setting is increased.

(See “DAMPER CONTROL”)

d.Adjust feed rate to desired setting by pressing “Heat Level Advance” button.

If fire doesn’t start in 15 minutes, press “On/Off”, wait a few minutes, clear the burnpot, and start procedure again.

DAMPER CONTROL

The damper control rod on the stove’s lower left side adjusts the combustion air. This control is necessary due to the varied burn characteristics of individual installations, different pellet brands and pellet feed rates. It allows you to improve the efficiency of your stove. Providing correct combustion air will reduce the frequency of cleaning your glass door and prevent the rapid buildup of creosote inside your stove and chimney.

You should adjust the damper based on the fire’s appearance. A low, reddish, dirty fire can be improved by pulling the damper out slightly. A “blow torch” fire can be improved by pushing the damper in a bit.

As a general rule, on lower feed rate settings, the damper should be in farther. On higher feed rates, the damper should be more open. Through trial and error, you will find the best setting. Consult your dealer if you need help.

NOTE: On “1”, damper should be out approximately ½” to ¾”. If damper is out too far, it can cause the fire to go out.

OPENING DOOR

If the door is opened while the stove is in operation it must be closed within 30 seconds or the stove will shut down. If the stove shuts down push the “On/Off” button to continue the operation of your stove.

ROOM AIR FAN

When starting your stove the Room Air Fan will not come on until the stove’s heat exchanger warms up. This usually takes about 10 minutes from start-up.

Image 16
Contents Tradition Series P24 Mail Your Warranty Card Today IntroductionSafety Precautions Table of Contents Installation SpecificationsPreparation Sidewall Clearances Alcove Clearances Floor ProtectionWhen Outside AIR is not Used Combustion AIR SupplyVenting Rear View P24FSA Rear View P24IFreestanding Installation Equivalent Vent Length EVLVertically with NEW Chimney System Refer to a & 9b Vertically Into Existing Chimney System Installation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceInsert Installations Assembling the Flashing SETWhen Vent Pipe Extends to Chimney TOP AS a BUILT-IN Fireplace Electrical Installation Special Mobile Home Requirements Installation in to a Factory Built Metal FireplaceOperation Proper Fuel PRE-START-UP CheckBuilding a Fire Hotrod Automatic FirestarterBreckwell Maintenance Tool Shutdown ProcedureSafety Features RE-STARTING a Warm StoveThermostat Installation Thermostat InstallationOptional Thermostat ∙ a Millivolt Thermostat is RequiredPlease Read this Maintenance ASH RemovalASH Disposal Freestanding Models ASH Disposal InsertCleaning Vacuum USEBlowers Rear View P24FSChimney Cleaning Recommended Maintenance ScheduleRemoval and Replacement of Broken Door Glass Daily Weekly Annually or per TonMaintenance Stove Shuts OFF and the # 2 Light Flashes Troubleshooting GuidePossible Causes Stove Shuts OFF and the # 3 Light Flashes Stove Feeds PELLETS, but will not Ignite Possible Causes Possible RemediesSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onTroubleshooting Guide Troubleshooting Guide High Limit Switch Keeps Tripping Heat Level Setting P24Smoke Smell or Soot BUILD-UP Digital Circuit Board Timing RatesElectrical Diagram Replacement Parts BurnpotLifetime Limited Warranty
Related manuals
Manual 9 pages 26.02 Kb Manual 32 pages 4.64 Kb

P24FS, P24I specifications

The Breckwell P24FS is a highly efficient pellet stove designed to provide both warmth and ambiance to your living space. Renowned for its dependable performance, this appliance combines cutting-edge technology with elegant design, making it a popular choice among homeowners seeking sustainable heating solutions.

One of the standout features of the P24FS is its impressive heating capacity. With the ability to effectively heat up to 2,000 square feet, the stove is equipped with a powerful 40,000 BTU output. This makes it suitable for various living spaces, from cozy cabins to larger family homes. Its large hopper capacity allows for extended burn times, which means less frequent refueling and more convenience for users.

The P24FS is engineered with advanced features such as an automatic ignition system, which simplifies startup and enhances efficiency. This stove also comes with a built-in thermostat, allowing users to maintain a consistent temperature effortlessly. The adjustable feed rate gives homeowners control over the amount of pellet fuel consumed, enhancing both efficiency and comfort.

Breckwell has incorporated a wide array of technologies into the P24FS to ensure optimal performance and safety. The stove features a substantial heat exchange system, which maximizes heat distribution throughout the room, while the integrated air wash system minimizes the buildup of soot on the glass door, ensuring a clear view of the mesmerizing flames.

Another notable characteristic of the P24FS is its aesthetic appeal. With a sleek and contemporary design, it complements a range of interior styles, from rustic to modern. The durable construction, combined with quality materials, ensures longevity and resilience.

In terms of EPA certifications, the Breckwell P24FS meets stringent emission standards, making it an environmentally friendly option for heating. Users appreciate the convenience of using fuel pellets, which are not only renewable but also offer a cleaner burn compared to traditional wood.

Overall, the Breckwell P24FS is a blend of efficiency, style, and user-friendliness. Its array of features, high heating capacity, and commitment to sustainability make it an excellent investment for those looking to enhance their home’s heating system with a reliable pellet stove. Whether it's for functional heating or creating a cozy atmosphere, the P24FS stands out as a top choice among its peers.