Breckwell P24FS, P24I owner manual Stove Shuts OFF and the # 3 Light Flashes

Page 25

TROUBLESHOOTING GUIDE

25

STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES

Possible Causes:

Possible Remedies: (Unplug stove first when possible)

 

 

 

1.

The hopper is out of pellets.

Refill the hopper.

 

 

 

2.

The air damper is too far open for a low feed setting.

If burning on the low setting, you may need to close the damper all

 

 

the way (push the knob in so it touches the side of the stove).

 

 

 

3.

The burnpot is not pushed completely to the rear of the firebox.

Make sure that the air intake collar on the burnpot is touching the

 

 

rear wall of the firebox.

 

 

 

4.

The burnpot holes are blocked.

Remove the burnpot and thoroughly clean it.

 

 

 

5.

The air inlet, the interior chambers, or exhaust system has a

Follow all cleaning procedures in the maintenance section of the

 

partial blockage.

owner’s manual.

 

 

 

6.

The auger shaft is jammed.

Start by emptying the hopper. Then remove the auger motor by

 

 

removing the auger pin. Remove the auger shaft inspection plate in

 

 

the hopper so that you can see the auger shaft. Gently lift the auger

 

 

shaft straight up so that the end of the auger shaft comes up out of

 

 

the bottom auger bushing. Next, remove the two nuts that hold the

 

 

top auger biscuit in. Then rotate the bottom end of the auger shaft

 

 

up towards you until you can lift the shaft out of the stove. After you

 

 

have removed the shaft, inspect it for bent flights, burrs, or broken

 

 

welds. Remove any foreign material that might have caused the

 

 

jam. Also, check the auger tube for signs of damage such as burrs,

 

 

rough spots, or grooves cut into the metal that could have caused a

 

 

jam.

 

 

 

7.

The auger motor has failed.

Remove the auger motor from the auger shaft and try to run the unit.

 

 

If the motor will turn the shaft is jammed on something. If the motor

 

 

will not turn, the motor is bad.

 

 

 

8.

The Proof of Fire (POF) thermodisk has malfunctioned.

Temporarily bypass the POF thermodisk by disconnecting the two

 

 

brown wires and connecting them with a short piece of wire. Then

 

 

plug the stove back in. If the stove comes on and works, you need

 

 

to replace the POF thermodisk. This is for testing only. DO NOT

 

 

LEAVE THE THERMODISC BYPASSED. Your blowers will never

 

 

shut off and if the fire went out the auger will continue to feed pellets

 

 

until the hopper is empty if you leave the POF thermodisk bypassed.

 

 

 

9.

The high limit thermodisk has tripped or is defective.

Wait for the stove to cool for about 30 - 45 minutes. It should now

 

 

function normally. If not use the owner’s manual to locate the high

 

 

limit thermodisk. To test if the thermodisk is bad, you can bypass it

 

 

as described previously for the POF thermodisk.

 

 

 

10.

The fuse on the control board has blown.

Remove the control board. On the back there is one fuse. If it

 

 

appears to be bad, replace it with a 5 Amp 250 Volt fuse. Plug the

 

 

stove back in and try to run the unit.

 

 

11. The control board is not sending power to the POF thermodisk

There should be a 5-volt (approximately) current going to the POF

 

or other auger system components.

thermodisk after the stove has been on for 10 minutes.

 

 

 

Image 25
Contents Tradition Series P24 Introduction Mail Your Warranty Card TodaySafety Precautions Table of Contents Specifications InstallationPreparation Sidewall Clearances Alcove Clearances Floor ProtectionCombustion AIR Supply When Outside AIR is not UsedVenting Rear View P24FSA Rear View P24IEquivalent Vent Length EVL Freestanding InstallationVertically with NEW Chimney System Refer to a & 9b Vertically Into Existing Chimney System Vertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneyAssembling the Flashing SET Insert InstallationsWhen Vent Pipe Extends to Chimney TOP AS a BUILT-IN Fireplace Installation in to a Factory Built Metal Fireplace Electrical Installation Special Mobile Home RequirementsOperation PRE-START-UP Check Proper FuelBuilding a Fire Hotrod Automatic FirestarterShutdown Procedure Breckwell Maintenance ToolSafety Features RE-STARTING a Warm StoveThermostat Installation Thermostat InstallationOptional Thermostat ∙ a Millivolt Thermostat is RequiredPlease Read this ASH Removal MaintenanceASH Disposal Freestanding Models ASH Disposal InsertVacuum USE CleaningBlowers Rear View P24FSRecommended Maintenance Schedule Chimney CleaningRemoval and Replacement of Broken Door Glass Daily Weekly Annually or per TonMaintenance Stove Shuts OFF and the # 2 Light Flashes Troubleshooting GuidePossible Causes Stove Shuts OFF and the # 3 Light Flashes Possible Causes Possible Remedies Stove Feeds PELLETS, but will not IgniteSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onTroubleshooting Guide Troubleshooting Guide Heat Level Setting P24 High Limit Switch Keeps TrippingSmoke Smell or Soot BUILD-UP Digital Circuit Board Timing RatesElectrical Diagram Burnpot Replacement PartsLifetime Limited Warranty
Related manuals
Manual 9 pages 26.02 Kb Manual 32 pages 4.64 Kb

P24FS, P24I specifications

The Breckwell P24FS is a highly efficient pellet stove designed to provide both warmth and ambiance to your living space. Renowned for its dependable performance, this appliance combines cutting-edge technology with elegant design, making it a popular choice among homeowners seeking sustainable heating solutions.

One of the standout features of the P24FS is its impressive heating capacity. With the ability to effectively heat up to 2,000 square feet, the stove is equipped with a powerful 40,000 BTU output. This makes it suitable for various living spaces, from cozy cabins to larger family homes. Its large hopper capacity allows for extended burn times, which means less frequent refueling and more convenience for users.

The P24FS is engineered with advanced features such as an automatic ignition system, which simplifies startup and enhances efficiency. This stove also comes with a built-in thermostat, allowing users to maintain a consistent temperature effortlessly. The adjustable feed rate gives homeowners control over the amount of pellet fuel consumed, enhancing both efficiency and comfort.

Breckwell has incorporated a wide array of technologies into the P24FS to ensure optimal performance and safety. The stove features a substantial heat exchange system, which maximizes heat distribution throughout the room, while the integrated air wash system minimizes the buildup of soot on the glass door, ensuring a clear view of the mesmerizing flames.

Another notable characteristic of the P24FS is its aesthetic appeal. With a sleek and contemporary design, it complements a range of interior styles, from rustic to modern. The durable construction, combined with quality materials, ensures longevity and resilience.

In terms of EPA certifications, the Breckwell P24FS meets stringent emission standards, making it an environmentally friendly option for heating. Users appreciate the convenience of using fuel pellets, which are not only renewable but also offer a cleaner burn compared to traditional wood.

Overall, the Breckwell P24FS is a blend of efficiency, style, and user-friendliness. Its array of features, high heating capacity, and commitment to sustainability make it an excellent investment for those looking to enhance their home’s heating system with a reliable pellet stove. Whether it's for functional heating or creating a cozy atmosphere, the P24FS stands out as a top choice among its peers.