Waterford Appliances E63-NG1 installation manual Optional Wall Thermostat, Test for Flue Spillage

Page 13

INSTALLATION

3)Attach the 4 grill clips with the 4 screws but do not tighten down at this point.

4) Place the grill into position on the front of the

door, center it in the front viewing area and

The smoke should be drawn into the draft hood. If the smoke is not drawn into the draft hood, turn the unit off and check for the cause of lack of draft.

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams. Note that the wires are connected to the "TH" on the gas valve. Use table below to determine the maximum wire length:

Note: Preferable if the thermostat is in- stalled on an interior wall.

Waterford offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 120V wires.

Thermostat Wire Table

use the grill clips to hold it in place.

5)Tighten the screws on the grill clips.

6)Replace the glass and secure the glass clips, reversing step 2)

7)Close the front door by reversing step 1).

TEST FOR FLUE

SPILLAGE

A "spillage" test must be made before the installed unit is left with the customer. Follow the procedure below:

1)Start all exhaust fans in the home and any other gas appliances. Then close all doors and windows.

2)Light the unit and set controls to maximum.

3)After five minutes, test that there is a "pull" on the flue by placing a smoke match, cigarette or similar device which gives off smoke, on the edge of the draft hood. See diagrams.

Note: If the flue is blocked or has a strong reverse flow, the thermally actuat- ed safety switch mounted in the draft hood will automatically shut off the gas supply within about 10 minutes. If the heater turns off because of this during the spillage test, check for the

The thermally activated safety switch must be manually reset before first star- tup.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

 

Wire Size

Max. Length

 

14 GA.

50 Ft.

 

16 GA.

32 Ft.

 

18 GA.

20 Ft.

 

20 GA.

12 Ft.

 

22 GA.

9 Ft.

 

 

 

 

 

 

 

 

OPTIONAL REMOTE

CONTROL

Use the Waterford Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very im- portant). Run wires from the fireplace to that location, use Thermostat Wire Table.

2)Connect the wires as per the wiring dia- gram on page 14.

CAUTION

Do not connect the millivolt

remote control wires to the 120V

wires.

Waterford E63-1 EMERALD Freestanding Gas Stove

13

Image 13
Contents 908-804 05/29/03 Models E63-NG1 Natural Gas E63-LP1 PropaneTo the New Owner Table of Contents Copy of the Safety Label for the E63-NG1 Natural Gas Safety LabelCopy of the Safety Label for the E63-LP1 Propane General Safety Information InstallationInstallation Checklist Before YOU StartThis includes Clearances to CombustiblesE63-NG1 & E63-LP1 Clearances High Elevation Draft HoodVenting GAS Pipe Pressure Testing Aeration AdjustmentGAS Connection Conversion KIT From Natural GAS To Propane Pilot assembly is now accessible For steps 6 toT. Valve Description Burner Orifice Natural Gas Kit # Propane Kit #E63/E65 Conversion Decal Natural Gas Conversion Kit ContainsLOG Installation Optional Door Grill InstallationDiagram Door Grill Kit ContainsDo not connect the millivolt Remote control wires to Wires Optional Remote ControlOptional Wall Thermostat Test for Flue SpillageFinal Check Wiring DiagramOperating Instructions Normal Operating Sounds GAS Appliances Copy Lighting Plate InstructionsMaintenance Instructions MaintenancePilot Adjustment LOG ReplacementReplacing Gasket FAN MaintenanceRemoving Valve To remove valve from valve assembly, continue Installing Valve AssemblyMain Assembly Parts ListDescription Burner & LOG Assembly Waterford E63-1 Emerald Freestanding Gas Stove Conditions WarrantyWaterford Product See the inside back cover for details

E63-NG1 specifications

Waterford Appliances has long been synonymous with quality and innovation in the kitchen appliance sector. Their E63-NG1 model embodies this legacy, combining cutting-edge technology with user-friendly design to deliver an exceptional cooking experience.

The E63-NG1 is a gas range that stands out for its stunning appearance, featuring a robust stainless steel finish that not only enhances durability but also adds a touch of elegance to any kitchen. Its sleek design is complemented by heavy-duty cast iron grates, which provide a stable cooking surface that easily supports pots and pans of various sizes.

One of the standout features of the E63-NG1 is its powerful burners. The range boasts a total of five burners, including a high-output burner that generates up to 18,000 BTUs, allowing users to achieve rapid boiling and high-heat searing. Additionally, the other burners, with a variety of BTUs ranging from 6,000 to 15,000, offer versatility for simmering, sautéing, and delicate cooking tasks. This array of burners ensures that home chefs have the flexibility to tackle multiple dishes simultaneously, enhancing overall cooking efficiency.

The E63-NG1 is equipped with a spacious oven that provides ample cooking space, accommodating large roasts and multiple trays. The oven features advanced convection technology, which ensures even heat distribution for perfectly baked goods, while reducing cooking times. The inclusion of multiple oven modes, including bake, broil, and a specialized pizza mode, adds to the appliance's versatility, making it an ideal choice for various culinary styles and preferences.

Another notable characteristic of the E63-NG1 is its user-friendly digital controls. The intuitive interface allows for precise temperature settings and timing, making cooking more straightforward and enjoyable. Additionally, the oven includes dual interior lights, ensuring that users can easily monitor their food without opening the door, which helps maintain optimal cooking temperatures.

Safety is also a priority in the E63-NG1 design. It features an automatic shut-off function that activates if the oven is left on for an extended period, giving users peace of mind. The appliance also offers a reliable ignition system that ensures a quick and safe start every time.

In summary, the Waterford Appliances E63-NG1 is a perfect blend of style, functionality, and safety. With its powerful burners, spacious oven, and innovative technologies, this gas range stands out as an excellent addition to any kitchen, catering to both day-to-day meals and special culinary projects alike. Whether you're a novice home cook or an experienced chef, the E63-NG1 delivers the performance and reliability needed to inspire culinary creativity.