WARNING: Dangerous operating condi- tions may occur if these logs are not positioned in their approved locations. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot and burner operation.

The gas log kit contains the following:

a)Front Right Log - Part # 902-245

b)Front Left Log - Part # 902-244

c)Rear log - Part # 902-246

d)Embers - Part # 902-151 (2 bags) e ) Lava - Part # 902-154 (1 bag)

(Part # 653-930 for the set of three logs)

1)Remove the logs from the box and carefully unwrap them. The logs are fragile, handle with care - DO NOT FORCE into position.

2)Place the rear log, carefully sliding it down onto the pins, with the flat side of the log facing the back of the unit. See diagram 1.

3)Place the left front log, carefully sliding it down onto the left pins of the front burner. See diagram 2.

4)Place the right front log, carefully sliding it down onto the right pins of the front burner. See diagram 3.

5)Distribute the embers along the front burner but do not cover the burner ports and around the logs. Place the large embers on the floor of the firebox. Place the lava on the burner tray in front of the left and right front logs. See diagram 4.

1)Open the two side doors.

2)Slide the door onto the two hinge pins making sure the two pieces are flush to- gether. See diagram 1.

Diagram 1

3)Close the door. The latch plate must be centered around the alignment pin. See diagram 2. If the latch plate interferes with the corner of the stove you may want to angle the plate slightly so the door closes more easily.

Diagram 1

Note: Do not force logs down.

Diagram 3

Diagram 2

4) The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by turning the latch. See diagram 3.

5) Remove the blue plastic protective coating.

Diagram 4

Diagram 2

6)Test the seal around the door by placing a piece of paper between the unit and the door, close the door and try to pull the paper

out. If it slips out easily, then the door is not p r o p e r l y

sealed. Turn the adjustable catch to tight- en or loosen the latch. See diagram 3.

Note: The door latch may require adjustment as

the door gasket material com- presses after a few fires and after glass replacement. Turn the latch to tighten or loosen the latch.

Regency U41-3 ULTIMATE Gas Fireplace Insert

11

Image 11
Contents U41 Gas Insert To the NEW Owner Regency GAS Fireplace InsertTable of Contents Safety Label Installation Circumstances Installation ChecklistClearances Extension High ElevationCombustible Mantel Clearances Venting Avoid damage to line when pushingGAS Connection Draft Hood Connection Combustion Ventilation AIRNatural Gas W.c Propane 11 w.c GAS Pressure TestAeration System Test for Flue SpillageDiagram Faceplate and Trim InstallationDoor Installation Packaged Separately LOG InstallationFinal Check Optional RemoteControl Wiring Diagram Operating Instructions Made in Canada 908-432 Copy of the Lighting Plate InstructionsPush in the gas control knob slightly and turn Clockwise Normal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions GOLD-PLATED Doors LOG ReplacementLatch Adjustment Glass ReplacementReplacing fan FAN MaintenanceTo remove fan Main Assembly Parts ListBurner & Logs Description Faceplate & TrimRegency U41-3 Ultimate Gas Fireplace Insert Warranty Lifetime WarrantyInstaller Please complete the following information