INSTALLATION

IMPORTANT:

SAVE THESE

INSTRUCTIONS

The Regency Gas Fireplace must be installed in accordance with these instructions. Care- fully read all the instructions in this manual first. Consult the building authority having jurisdic- tion to determine the need for a permit prior to starting the installation.

Note: Failure to follow these instruc- tions could cause a malfunction of the heater which could result in death, serious bodily injury, and/ or property damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

FOR YOUR SAFETY

This appliance requires air for proper combus- tion. Always provide adequate combustion and ventilation air. Follow instructions and information in the current CAN/CGA B149 (in Canada) or the current National Fuel Gas Code ANSI Z223.1 (in the USA), regarding require- ments for combustion and ventilation air.

GAS PIPE TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa).

SPECIFICATIONS

Fuel: Natural gas or Propane

Electrical: 120V A.C. system.

Fan/Blower: Variable speed, 125/75 CFM.

Log Sets: Ceramic fiber, 3 per set.

Vent System: Listed minimum 4" B-Vent or listed double thickness aluminium flex liner.

INSTALLATION INTO A

FACTORY BUILT

FIREPLACE

The ULTIMATE Gas Inserts have been tested and approved to be vented into any approved Factory Built Fireplace that will allow the Insert to physically fit into the firebox. A Factory Built

Fireplace Trim Kit, Part # 610-940, is available.

If the factory built fireplace height is too

low for your Insert, you may remove the

smoke shelf, baffle plate, and damper

plate from the factory built fireplace if

removable without cutting or torching,

as long as these items are saved and are

re-installed in the event that the Insert is

removed.

INSTALLATION INTO ZERO CLEARANCE FIREPLACES

The ULTIMATE Gas Inserts are only approved

for installation into the ULTIMATE Gas

Insert Zero Clearance Fireplace Kit, mod-

el # 660-900.

BEFORE YOU START

Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

General Safety Information

1)The appliance installation must conform with local codes or in the absence of local codes, with current CAN/CGA B149 (in Canada) or the current National Fuel Gas Code ANSI Z223.1. This appliance MUST be installed by a qualified gas fitter technician only.

2)Installation and repair should be done by a qualified service person.

3)The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imper- ative that control compartments, burners and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.

4)See general construction and assembly instructions. This appliance may only be installed in a vented, non-combustible fire- place. The appliance and vent should be enclosed when installed in or passing through a living area, where children may come in contact with it.

5)This appliance is Listed for bedroom instal- lations when used with a Listed Millivolt

Thermostat. Some areas may have further requirements, check local codes before installation.

6)This unit is not approved for installation into a mobile home.

7)Always connect this fireplace to a chimney and vent to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is properly sized and is of adequate height to provide the proper draft.

8)Inspect the venting system annually for blockage and any signs of deterioration.

9)Any safety glass removed for servicing must be replaced prior to operating the appliance.

10)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

11)Due to high temperatures, the appliance should be located out of high traffic areas and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures, especially the fireplace glass and gold trims, and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or otherflammablematerialshouldnotbeplaced on or near the appliance.

12)WARNING: Failure to position the parts in accordance with the diagrams in this manual or failure to use only parts specifically approved with this appli- ance may result in property damage or personal injury.

13)WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system or tamper- ing with the blocked vent shut-off system can result in carbon monoxide (CO) poison- ing and possible death.

14)This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

MATERIALS

REQUIRED

No electrical power supply is required for the gas control to operate. A 120 Volt AC power

Regency U41-3 ULTIMATE Gas Fireplace Insert

5

Image 5
Contents U41 Gas Insert To the NEW Owner Regency GAS Fireplace InsertTable of Contents Safety Label Installation Circumstances Installation ChecklistClearances Extension High ElevationCombustible Mantel Clearances GAS Connection Avoid damage to line when pushingDraft Hood Connection Combustion Ventilation AIR VentingAeration System GAS Pressure TestTest for Flue Spillage Natural Gas W.c Propane 11 w.cDiagram Faceplate and Trim InstallationDoor Installation Packaged Separately LOG InstallationFinal Check Optional RemoteControl Wiring Diagram Operating Instructions Made in Canada 908-432 Copy of the Lighting Plate InstructionsPush in the gas control knob slightly and turn Clockwise Normal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions Latch Adjustment LOG ReplacementGlass Replacement GOLD-PLATED DoorsReplacing fan FAN MaintenanceTo remove fan Main Assembly Parts ListBurner & Logs Description Faceplate & TrimRegency U41-3 Ultimate Gas Fireplace Insert Warranty Lifetime WarrantyInstaller Please complete the following information