Regency F2400M, S2400M Masonry Chimney, Masonry Fireplace, Factory Built Chimney

Page 12

INSTALLATION

MASONRY

CHIMNEY

Ensure that a masonry chimney meets the mini- mum standards of the National Fire Protection Association (NFPA) by having it inspected by a professional. Make sure there are no cracks, loose mortar or other signs of deterioration and blockage. Have the chimney cleaned before the stove is installed and operated. When connecting the stove through a combustible wall to a masonry chimney, special methods are needed.

MASONRY

FIREPLACE

There are listed kits available to connect a stove to a masonry fireplace. The kit is an adapter that is installed at the location of the fireplace damper. The existing damper may have to be removed to allow installation.

FACTORY

BUILT CHIMNEY

When a metal prefabricated chimney is used, the manufacturer's installation instructions must be followed. You must also purchase and install the ceiling support package or wall pass-through and "T" section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation.

12

Regency Freestanding Woodstove

Image 12
Contents Freestanding Woodstove 02/15/06Regency Fireplace Product Modular PartsTable of Contents Safety Label Safety Label for F2400MSafety Label for S2400M 20062005 245Installation Unit DimensionsResidential Installation Modular Installation OptionsModular Part Things to consider when choosing options F2400M, S2400MResidential Installation C Vent Single Wall Room AIRMinimum Clearance to Combustible Materials Minimum Alcove Clearance to Combustible Materials Floor ProtectionStove Assembly Prior to Installation Airmate Assembly for F2400MS2400M Side Shield Adjustment 815-555STEP-BY-STEP Chimney Connector Installation Leg and Bottom Shield AssemblyMasonry Chimney Masonry FireplaceFactory Built Chimney Combustible Wall Chimney Connector PASS-THROUGHS Method a 12 304.8 mm Clearance to Combustible Wall MemberRecommended Heights for Woodstove Flue Recommended Flue HeightElevation Example a Example bMobile Home Installation Listed Components For Mobile Home Installation Flue Baffle Secondary AIR Tube InstallationInstallation Canadian InstallationsBrick Installation STEP-BY-STEP Optional Accessories InstallationGlass Installation Door HandleBlower/Fan Wiring Diagram Operating Instructions Operating InstructionsDraft Control First FireSafety Guidelines Safety PrecautionsFAN Operation ASH DisposalMaintenance Parts List F2400M Stove Main AssemblyPart# Description Parts List S2400M Step Stove Main AssemblyPEDESTAL, Bottom Shield & LEG Options Firebrick Regency Freestanding Woodstove Warranty Warranty LifetimeInstaller Please complete the following information