SAFETY LABEL
This is a copy of the label that accompanies each Regency Medium Freestanding Step Stove (S2400M). We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
SAFETY LABEL FOR S2400M
LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO DO NOT REMOVE THIS LABEL | |||
SUITABLE FOR MOBILE HOME INSTALLATION |
| 245 |
|
|
|
| |
MODEL: REGENCY MEDIUM FREESTANDING STEP STOVE - S2400M | |||
TESTED TO: UL1482 / ULC S627 / UL 737 | REPORT NO: | ||
THE S2400M MEETS UL737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED. |
|
| INSTALLAND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. |
|
| |
|
| CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. |
|
| USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT |
|
| |
|
| SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A |
|
| CHIMNEY THROUGHACOMBUSTIBLE WALL OR CEILING. DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE |
S2400M | WALL OR CEILING. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. |
OCT NOV DEC
S2400M MINIMUM CLEARANCES | |||||
TO COMBUSTIBLE MATERIALS | |||||
|
|
|
|
|
|
MEASURE |
|
|
|
| FLUE |
FROM |
| HEATER |
|
| |
RESIDENTIAL INSTALLATION USING | |||||
|
| SINGLE WALL CONNECTOR | |||
SIDEWALL |
| A 406 mm / 16 in |
|
| D 711 mm / 28 in |
|
|
| |||
BACKWALL |
| B 280 mm / 11 in |
|
| E 444 mm / 17.5 in |
CORNER |
| C 152 mm / 6 in |
|
| F 444 mm / 17.5 in |
INSTALLATION USING LISTED DOUBLE WALL | |||||
| CONNECTOR - MOBILE HOME | ||||
SIDEWALL |
| A 380 mm / 15 in |
|
| D 685 mm / 27 in |
|
| ||||
BACKWALL |
| B 140 mm / 5.5 in |
|
| E 304 mm / 12 in |
CORNER |
| C 102 mm / 4 in |
|
| F 393 mm / 15.5 in |
INSTALLATION USING LISTED DOUBLE WALL | |||||
CONNECTOR - RESIDENTIAL CLOSE CLEARANCE | |||||
SIDEWALL |
| A 380 mm / 15 in |
|
| D 685 mm / 27 in |
|
|
| |||
BACKWALL |
| B 140 mm / 5.5 in |
|
| E 304 mm / 12 in |
CORNER |
| C 102 mm / 4 in |
|
| F 393 mm / 15.5 in |
|
|
|
|
|
|
INSTALLATION USING LISTED DOUBLE WALL | |||||
|
| CONNECTOR - ALCOVE | |||
SIDEWALL |
| G 380 mm / 15 in |
|
| I 685 mm / 27 in |
|
|
| |||
BACKWALL |
| H 140 mm / 5.5in |
|
| J 304 mm / 12 in |
|
|
|
|
|
|
MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT | MAXIMUM ALCOVE DEPTH 915 MM / 36 IN. |
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
| FLOOR | BACK M |
| |
|
| O | L | |
PROTECTION* | SIDE | |||
|
|
| DE | |
K | 405 mm / 16 in |
|
| SI |
L | 150 mm / 6 in |
|
|
|
M 150 mm / 6 in |
|
|
|
K FRONT
*In Canada, ßoor protection must extend 18" (450mm) to the front and 8" (200mm) to each side and back of the stove.
MAR APR MAY JUN JUL AUG SEPT
FOR USE WITH SOLID WOOD FUEL ONLY. USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT COMBUSTION AIR OPENINGS. OPERATE ONLY WITH FIREBRICKS IN PLACE. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED.
IF INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPERATED WITH DOORS OPEN THE MANUFACTURER SUPPLIED SCREEN MUST BE USED. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING. INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER. REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY
OPTIONAL COMPONENT: FAN
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN FRONT OF APPLIANCE.
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA: LISTED SECURITY MODEL DP, OR OLIVER MACLEOD
IN USA: LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, GSW SUPER PIPE 6,
MANUFACTURED BY: FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 VENTURE ST.
DELTA, BC V4G 1H4
MADE IN CANADA
UNITED STATES ENVIRONMENTAL | CERTIFIED TO COMPLY WITH JULY 1990 |
PROTECTION AGENCY | PARTICULATE EMISSION STANDARDS. |
|
|
| CAUTION |
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
rev. 11/05
JAN FEB
OF MANUFACTURE | 2006 2007 |
DATE | 2005 |
Regency Freestanding Woodstove | 5 |