Installation (for qualified installers only)

Insert with

Positive

Connection

NOTE:

Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for installation and support.

Install a non-combustible cover plate to prevent water from entering the chimney

Combustible Mantle

Surround Panels

See the section "Insert Placement Requirements" for minimum clearances and hearth required.

Cap (prevents water

from entering)

Flue Liner

The liner must be stainless steel connector or flexible vent. Follow the liner manufacturer's

insturctions for installation and

support.

Airtight Insulated Clean-Out

Remove damper or wire it open

Figure 6

Insert with Direct

Connection

NOTE:

Direct connections require installation of an airtight block-off plate or damper

adapter (see "Block-off Combustible Mantle Plate Installation" on

page 11).

Surround Panels

See the section "Insert Placement Requirements" for minimum clearances and hearth required.

Flue

Liner

Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner

Airtight

Insulated

Clean-Out

Remove damper or wire it open

Block-off plate or damper adapter

© Travis Industries

100-01163

4041129

Image 12
Contents Freedom Bay Fireplace Insert Mail your Warranty Card Today, and Save Your Bill of Sale 2IntroductionIntroduction Important Information Table of Contents Safety Precautions AshesTravis Industries, Inc. grants no warranty, implied or MobileFeatures & Specifications Planning The Installation Preparation for InstallationAdditional Accessories Needed for Installation Installation ConsiderationsMinimum Fireplace Size Fireplace RequirementsInsert Placement Requirements Hearth RequirementsMasonry Fireplace Requirements Leveling Bolt Installation Blower InstallationDrafting Performance Block-Off Plate Installation Block-Off Plate TemplateInsert with Positive Connection Insert with Direct ConnectionInsert with Face Seal Connection Safety Notice Operating Your ApplianceBefore Your First Fire Opening the DoorBypass Operation Starting a Fire Adjusting the Burn Rate Approximate Air Control SettingsAsh Removal Blower Operation Re-Loading the StoveOvernight Burn Normal Operating SoundsTesting Wood Moisture Why Dry Wood is KeyHints for Burning Selecting WoodTroubleshooting Daily Maintenance while stove is in use Clean the Glass if necessaryMaintaining Your Appliance Remove Ash if necessaryMonthly Maintenance while appliance is in use Door and Glass InspectionCreosote Formation and Need for Removal Yearly Maintenance Cleaning the Air Duct and BlowerTouch Up Paint Firebrick and Baffle InspectionDoor Parts Replacing the GlassReplacing the Door Gasket Replacing the Door HandleFirebox Parts Floor and Side FirebrickBaffle Removal & Replacement Air Tube Removal & ReplacementLimited 7 Year Warranty Years 1 & 2 Coverage Parts & LaborYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyListing Label Listing LabelDoor Shell Installation Optional EquipmentSocket Side Frame Installation Instructions Insulation InstallationRequired only for face seal installations Surround PanelsIndex