Majestic CVR36 Install Remainder of Chimney Sections, Air Space Clearances, Finishing Finish Wall

Page 14

STR/CVR Series Woodburning Fireplaces

WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS.

Mark an outline of the roof hole around the center of the point nail. NOTE: Hole dimensions given in the chim- ney top installation instructions are horizontal dimen- sions; therefore, the hole size must be marked on the roof accordingly.

Cover the opening of the installed chimney so debris cannot get into the system.

Cut and frame the hole. It is good practice to use fram- ing lumber that is the same size as the rafters. Install the frame securely because the chimney top and flash- ing anchored to the frame must be able to withstand heavy winds.

Install Remainder of Chimney Sections

Air Space Clearances

Combustible framing material MUST NOT penetrate AIR SPACE (shaded areas).

1���" (38mm)

������

������

1"

Standoff

(51mm)

�����������

 

����

 

 

MaintainOUTER

���" (13mm) air space

����"DOME(13mm)

air space

to sides

to sides

Front View

Side View

Since you have already preplanned the height of your termination according to the Ten Foot Rule, continue to install pipe to the predetermined height.

Check the chimney top installation instructions for details on how high above the roof top the chimney sec- tions (all pipes) should extend.

Installing Top Housing or Termination

Follow the installation instructions provided with the chimney termination you have selected.

Installing Chimney In a Chase

Refer to Page 5, Figure 4 for an illustration of a typical chase installation.

CAUTION: Treatment of firestop spacers and construc- tion of chase may vary with type of building. These instructions are not a substitute for local building codes. You must check your local building codes to determine specific requirements for your city or state. NOTE: Other building materials may be required in addition to

Wall

Shield

Only noncombustible material may be applied as facing to the black fireplace surround.

Firestop

���" (13mm) Air Space to Sides

0" Clearance to Floor

Hearth Extension

FP717

Firestop Spacers.

Finishing

CAUTION: All joints between the finished wall and the fireplace surround (top/sides) must be sealed with non- combustible material to prevent cold air leakage into the room. Only noncombustible material may be applied to the facing of the fireplace surround. (Black painted area) (Fig. 20)

Finish Wall

Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12" (305mm) above the front opening. Do not install a mantel face plate less than 6" (159mm) from top of fireplace opening. (Fig. 21) If a combustible mate-

Fig. 20 Minimum clearances to combustibles.

rial is used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fire- place opening to bottom of mantel shelf.

NOTE: No side wall protection is required for fireplaces installed at 45° to two (2) side walls (corner installation).

Adjacent combustible side walls that are within 16" (406mm) (STR33/36 and CVR36) and 20" (508mm) (STR42 and CVR42) of fireplace opening must be pro- tected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described in Figure 20 & 24.

Often a decorative surround or vertical portion of the mantel is desired. If this is constructed of any combus- tible material, it must be within the safe zone indicated in Figure 24.

14

7412961

Image 14
Contents STR/CVR Series Safety Information Table of ContentsSTR Series Woodburning Fireplace CVR Series Woodburning FireplaceSTR/CVR Series Woodburning Fireplace Chase Installation 30˚ Elbow Offsets Illustration KeyPlanning the Chimney Run Planning InformationMounting the Fireplace Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesFraming Straight-Up Chimney InstallationOffset Installation Chimney Set-upFraming the Ceiling Hole Ceiling Chimney Hole Possible ObstructionsCutting the Hole Positioning, Safety Strips Securing the Fireplace Outside Air KitProper Firestop Spacer Installation Installing the Chimney SystemInstalling the Firestop Spacer Ceiling Hole Additional Ceilings Continue Installing Pipe to Complete RunCanadian Requirements For Insulation Shield Penetrating the RoofInstalling Chimney In a Chase Install Remainder of Chimney SectionsInstalling Top Housing or Termination Air Space ClearancesSTR/CVR Series Woodburning Fireplaces Side Wall Protection Examples of wall shield insulationMinimum Wall Clearances Minimum Hearth Extension DimensionsHearth Installation Common Materials and Factors Installing Line for Gas Logs Gas line accessCVR36/42 Series STR33/36/42 Series Accessories 33GDKDP STR33 36GDKDP STR36 42GDKDP STR42Chimney Components RLTSK8Chimney Components, contd STR/CVR Series Woodburning Fireplaces STR/CVR Series Woodburning Fireplaces Limited Warranty & 30 Year Protection Plan For Majestic Fireplaces PRE-ENGINEERED Fireplace SystemsCFM Corporation