Majestic STR36, CVR42, STR42, STR33, CVR36 manual 30˚ Elbow Offsets, Illustration Key

Page 6

STR/CVR Series Woodburning Fireplaces

Chimney Requirements - Offset Installations

CHIMNEY FLUE EXIT

 

 

CHIMNEY

 

 

 

 

 

SECTION

 

 

 

 

 

ELBOW

 

30˚

 

 

 

 

RETURN

 

 

 

B

 

 

A

 

G

ELBOW

 

 

 

 

 

 

 

 

 

30˚

G

 

 

 

 

 

D

 

 

 

OFFSET

 

E

RISE

 

ELBOW

 

 

 

 

 

C

6 FT.

 

 

30˚

SKCS8

 

 

 

 

 

H

 

RETURN

SUPPORT

 

OFFSET

 

ELBOW

 

 

 

 

 

H

 

 

 

 

30˚

B

 

 

 

 

 

 

 

OFFSET

 

 

 

 

 

ELBOW

 

 

HEARTH

 

 

 

 

FLOOR

 

 

 

 

Example 1

 

Example 2

 

Example 3

Notes: G + H cannot exceed 20 feet.

 

 

FP720

Air Space Clearances:

 

 

 

 

SK8 (2-wall) = 1¹⁄" , and 11CF (2-wall) = 2"

 

 

OFFSET

RISE

 

 

 

 

 

 

 

FP282

 

30˚ Elbow Offsets

 

 

 

 

 

 

 

 

1' 1¹⁄₂'

3'

4'

Chimney Support

Offset

Rise

 

 

 

 

 

 

 

 

0

0

0

0

0

3"

11"

 

1

0

0

0

0

8¹⁄"

20"

 

0

1

0

0

0

11¹⁄" 25¹⁄"

 

2

0

0

0

0

13¹⁄" 29¹⁄"

 

1

1

0

0

0

16¹⁄" 34¹⁄"

 

0

0

1

0

0

20¹⁄" 40³⁄"

 

2

1

0

0

0

21³⁄" 43¹⁄"

 

0

0

0

1

0

26¹⁄" 51¹⁄"

 

0

1

1

0

0

28¹⁄" 55¹⁄"

 

1

0

0

1

0

31¹⁄" 60¹⁄

 

0

1

0

1

0

34¹⁄" 65¹⁄"

 

0

0

2

0

0

37¹⁄" 70³⁄"

 

1

1

0

1

1

41¹⁄" 77³⁄"

 

0

0

1

1

1

45" 83³⁄"

 

0

1

2

0

1

47¹⁄" 87¹⁄"

 

0

0

0

2

1

51"

94"

 

0

1

1

1

1

53¹⁄"

98"

 

0

0

3

0

1

56¹⁄"

103¹⁄"

Illustration Key

The following safety rules apply to offset installations (letters correspond with illustration above):

A. Height of the chimney is measured from the hearth to the chimney exit.

 

CVR / STR Series

Maximum:

90'0"

Minimum:

 

Without Elbows

15'6"

With 2 Elbows*

17'6"

With 4 Elbows*

21' 0"

B. Do not use more than 4 elbows per chimney.

Attach the straps of the return (top) elbow to a structural framing member.

The offset (first) elbow of any pair does not have straps.

* In Canada, two (2) SK845 are allowed.

C. The chimney cannot be more than 30˚ (45˚ in Canada) from the vertical plane in any installation*.

D. The maximum length of the angled run of the total chimney system is 20 feet. (G plus H cannot exceed 20 feet.)

E. A chimney support (Models TCS8A or 11CS) is required every 6 feet of angled run of chimney. Chimney supports are re- quired for every 30 feet and 60 feet (SK8

&CF11 pipe) of vertical chimney height above the hearth.

Determine the offset distance of your chimney arrangement from the centerline of the fireplace to the centerline of the chimney where it is to pass through the first ceiling.

NOTE: This offset distance may not be your full offset distance. See Examples 2 and 3.

0

1

0

2

1

59¹⁄" 108¹⁄"

0

0

2

1

1

62¹⁄" 113¹⁄"

0

1

3

0

1

64¹⁄" 117¹⁄"

0

0

1

2

1

68¹⁄"

124"

0

1

2

1

1

70¹⁄"

128"

0

0

0

3

1

74¹⁄" 134¹⁄"

0

1

1

2

2

78" 140³⁄"

0

0

3

1

2

81"

146"

0

1

0

3

2

84" 151¹⁄"

0

0

2

2

2

87" 156¹⁄"

0

1

3

1

2

89¹⁄" 160¹⁄"

0

0

1

3

2

93" 166³⁄"

0

1

2

2

2

95¹⁄" 170³⁄"

0

0

0

4

2

99¹⁄" 177³⁄"

0

1

1

3

2

101¹⁄" 181³⁄"

0

0

3

2

2

104¹⁄" 186¹⁄"

0

1

0

4

2

107¹⁄" 191¹⁄"

0

0

2

3

2

110¹⁄" 196³⁄"

0

1

3

2

3

114" 203¹⁄"

0

0

1

4

3

117³⁄" 209³⁄"

0

1

2

3

3

120" 213¹⁄"

0

0

0

5

3

123³⁄"

220"

Fig. 5 Chimney system requirements.

6

7412961

Image 6
Contents STR/CVR Series Safety Information Table of Contents STR Series Woodburning Fireplace CVR Series Woodburning FireplaceSTR/CVR Series Woodburning Fireplace Chase Installation 30˚ Elbow Offsets Illustration KeyPlanning the Chimney Run Planning InformationMounting the Fireplace Ten Foot RuleChimney Supports InstallationChase Installation Insulating Fireplace Enclosure for Cold ClimatesFraming Straight-Up Chimney InstallationOffset Installation Chimney Set-upCeiling Chimney Hole Possible Obstructions Cutting the HoleFraming the Ceiling Hole Positioning, Safety Strips Securing the Fireplace Outside Air KitInstalling the Chimney System Installing the Firestop Spacer Ceiling HoleProper Firestop Spacer Installation Additional Ceilings Continue Installing Pipe to Complete RunCanadian Requirements For Insulation Shield Penetrating the RoofInstalling Chimney In a Chase Install Remainder of Chimney SectionsInstalling Top Housing or Termination Air Space ClearancesSTR/CVR Series Woodburning Fireplaces Side Wall Protection Examples of wall shield insulationMinimum Hearth Extension Dimensions Hearth InstallationMinimum Wall Clearances Common Materials and Factors Installing Line for Gas Logs Gas line accessCVR36/42 Series STR33/36/42 Series Accessories 33GDKDP STR33 36GDKDP STR36 42GDKDP STR42Chimney Components RLTSK8Chimney Components, contd STR/CVR Series Woodburning Fireplaces STR/CVR Series Woodburning Fireplaces Limited Warranty & 30 Year Protection Plan For Majestic Fireplaces PRE-ENGINEERED Fireplace SystemsCFM Corporation