Regency E33S installation manual GAS Pipe Pressure Testing, GAS Insert Aeration System

Page 11

INSTALLATION

GAS PIPE

PRESSURE TESTING

The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. (3.45 kPa). Disconnect piping from valve at pressures over 1/2 psig.

The manifold pressure is controlled by a regulator built into the gas control, and should be checked at the pressure test point.

NOTE: To properly check gas pressure, both inlet and manifold pressures should be checked using the valve pressure ports on the valve.

1)Make sure the valve is in the "OFF" position.

2)Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver.

3)Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose.

4)Light the pilot and turn the valve to "ON" position.

5)The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label.

6)When finished reading manometer, turn off the gas valve, disconnect the hose and tighten the screw (clockwise) with a 1/8" flat screwdriver. Note: Screw should be snug, but do not over tighten.

SIT VALVE DESCRIPTION

1)Gas on/off knob

2)Manual high/low adjustment

3)Pilot Adjustment

4)Thermocouple Connection - option

5)Manifold (Outlet) Pressure Tap

6)Inlet Pressure Tap

1

2

3

4

IN OUT

65

7)Pilot Outlet

8)Main Gas Outlet

9)Alternative TC Connection Point

GAS INSERT

AERATION SYSTEM

The burner aeration is factory set but may need adjusting due to either the local gas supply or altitude. Open the air shutter for a blue flame or close for a more yellow flame.

The burner assembly will need to be removed in order to adjust burner aeration if required. See steps 1-4 in "Conversion Kit# 434-969 from NG to LP".

Minimum Air Shutter Opening:

1/8" Natural Gas

1/4" Propane

CAUTION: Carbon will be produced if the air shutter is closed too much.

Note: Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty.

Note: Aeration Adjustment should only be performed by an authorized FPI Installer at the time of installation or service.

INSTALLATION

Regency® E33S-1 Sunrise Gas Insert

11

Image 11
Contents E33 Sunrise Gas Insert FPI GAS Fireplace Insert Table of Contents Safety Label MA Code CO Detector RequirementsUnit Dimensions Installation Materials Required Installation ChecklistMinimum Fireplace Opening Minimum Clearances to Combustibles Venting Flue Liner InstallationGAS Connection GAS Insert Aeration System GAS Pipe Pressure TestingConversion KIT #434-969FROM NG to LP Installation Installation Are away from sharp Wiring DiagramsWires do not touch Any hot surfacesOptional Wall Thermostat Thermostat Wire TableGlass Door Installation Glass Crystal or Optional Ceramic Stones InstallationKit# 341-914 Contents List Contemporary Faceplate Door Frame InstallationCompleted Faceplate & Door Frame Installation Hearth Trim 341-942 Installation Optional Hearth Trim InstallationOperating Instructions Normal Operating Sounds GAS Appliances Copy of Lighting Instruction PlateAutomatic Convection FAN Operation Glass Replacement MaintenanceMaintenance Instructions General Vent MaintenanceDoor Frame Valve Tray ReplacementBase Cover FAN Replacement Maintenance Main Assembly Parts ListContemporary Faceplate & Door Frame Regency E33S-1 Sunrise Gas Insert Conditions WarrantyInstaller Please complete the following information

E33S specifications

The Regency E33S is a remarkable venture into the realm of compact, feature-rich functional appliances, specifically engineered to cater to a variety of user needs. Designed with elegance and functionality in mind, the E33S stands out due to its modern aesthetic and advanced technology.

One of the main features of the Regency E33S is its powerful energy-efficient system, which ensures optimal performance while minimizing electricity consumption. This appliance is equipped with a high-efficiency compressor that not only reduces energy costs but also maintains a consistent temperature, contributing to the longevity of the items stored within.

In terms of capacity, the E33S boasts ample storage space, making it an excellent choice for both residential and commercial users. With intelligently designed shelving arrangements, it allows for the maximum utilization of space, accommodating various sizes and types of items. The adjustable shelves provide flexibility, which is essential for diverse storage needs.

The E33S is also integrated with innovative smart technology. Featuring Wi-Fi connectivity, users can monitor and control the appliance remotely, ensuring optimal performance and peace of mind. The accompanying mobile application allows for temperature adjustments, alerts for any fluctuations, and energy usage tracking, making it a highly user-friendly solution.

In addition, the Regency E33S prioritizes hygiene and freshness. It is equipped with advanced filtration systems that minimize odors and effectively filter out contaminants. This feature is particularly beneficial for preserving food quality and extending shelf life.

Another notable aspect of the E33S is its sleek design, which fits seamlessly into any decor. The appliance is available in various finishes, allowing users to choose one that complements their space beautifully. The exterior is not only stylish but also durable, ensuring longevity.

Lastly, built with eco-friendly materials, the Regency E33S reflects a commitment to sustainability. Its construction takes into account environmental impact, making it an ideal choice for eco-conscious consumers.

In conclusion, the Regency E33S combines efficiency, innovative technology, and elegant design to meet the diverse needs of modern users, setting a new standard in the compact appliance market.