INSTALLATION

INSTALLATION

For PROPANE Units and Units Equipped with DC Spark Boxes*

*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.

OPTIONAL REMOTE

3) Install 3AAAalkaline batteries in transmitter

 

CONTROL

and 4 AA alkaline batteries in the receiver.

Install the receiver and its cover in the wall.

 

Switch the remote receiver to "remote"

Use the FPI Remote Control Kit approved for

mode. The remote control is now ready

for operation. Refer to Remote manual for

this unit. Use of other systems may void your

complete details.

warranty.

 

It is recommended that the thermostat be installed on an interior wall.

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 120V wires.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fireplace to that location. Use Thermostat Wire Table.

2)Connect the wires as per the wiring diagrams below.

CAUTION

Do not connect the millivolt

remote control wires

to the 120V wires.

 

T

O

 

 

 

 

O

N

I

 

TH

To wall switch,

 

 

 

P

 

 

H

 

I

 

 

 

 

L

 

 

 

 

 

 

 

F

 

 

 

 

remote control

 

FO

 

 

OL

TP

 

 

 

 

 

or thermostat

 

 

 

 

 

 

 

 

 

 

THTP

 

 

 

 

 

 

 

To thermopile

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired, follow the wiring diagram. Note: the wires are connected to the "TH" on the gas valve. Use the table below to determine the maximum wire length. FPI offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

 

 

14 GA.

50 Ft.

 

 

16 GA.

32 Ft.

 

 

18 GA.

20 Ft.

 

 

20 GA.

12 Ft.

 

 

22 GA.

9 Ft.

 

 

16

Regency® E33S-1 Sunrise Gas Insert

Image 16
Contents E33 Sunrise Gas Insert FPI GAS Fireplace Insert Table of Contents Safety Label Requirements MA Code CO DetectorUnit Dimensions Installation Minimum Fireplace Opening Installation ChecklistMaterials Required Minimum Clearances to Combustibles GAS Connection Flue Liner InstallationVenting GAS Pipe Pressure Testing GAS Insert Aeration SystemConversion KIT #434-969FROM NG to LP Installation Installation Wiring Diagrams Wires do not touchAny hot surfaces Are away from sharpThermostat Wire Table Optional Wall ThermostatGlass Crystal or Optional Ceramic Stones Installation Glass Door InstallationContemporary Faceplate Door Frame Installation Kit# 341-914 Contents ListCompleted Faceplate & Door Frame Installation Optional Hearth Trim Installation Hearth Trim 341-942 InstallationOperating Instructions Automatic Convection FAN Operation Copy of Lighting Instruction PlateNormal Operating Sounds GAS Appliances Maintenance Maintenance InstructionsGeneral Vent Maintenance Glass ReplacementValve Tray Replacement Door FrameBase Cover FAN Replacement Maintenance Parts List Main AssemblyContemporary Faceplate & Door Frame Regency E33S-1 Sunrise Gas Insert Warranty ConditionsInstaller Please complete the following information

E33S specifications

The Regency E33S is a remarkable venture into the realm of compact, feature-rich functional appliances, specifically engineered to cater to a variety of user needs. Designed with elegance and functionality in mind, the E33S stands out due to its modern aesthetic and advanced technology.

One of the main features of the Regency E33S is its powerful energy-efficient system, which ensures optimal performance while minimizing electricity consumption. This appliance is equipped with a high-efficiency compressor that not only reduces energy costs but also maintains a consistent temperature, contributing to the longevity of the items stored within.

In terms of capacity, the E33S boasts ample storage space, making it an excellent choice for both residential and commercial users. With intelligently designed shelving arrangements, it allows for the maximum utilization of space, accommodating various sizes and types of items. The adjustable shelves provide flexibility, which is essential for diverse storage needs.

The E33S is also integrated with innovative smart technology. Featuring Wi-Fi connectivity, users can monitor and control the appliance remotely, ensuring optimal performance and peace of mind. The accompanying mobile application allows for temperature adjustments, alerts for any fluctuations, and energy usage tracking, making it a highly user-friendly solution.

In addition, the Regency E33S prioritizes hygiene and freshness. It is equipped with advanced filtration systems that minimize odors and effectively filter out contaminants. This feature is particularly beneficial for preserving food quality and extending shelf life.

Another notable aspect of the E33S is its sleek design, which fits seamlessly into any decor. The appliance is available in various finishes, allowing users to choose one that complements their space beautifully. The exterior is not only stylish but also durable, ensuring longevity.

Lastly, built with eco-friendly materials, the Regency E33S reflects a commitment to sustainability. Its construction takes into account environmental impact, making it an ideal choice for eco-conscious consumers.

In conclusion, the Regency E33S combines efficiency, innovative technology, and elegant design to meet the diverse needs of modern users, setting a new standard in the compact appliance market.