Weil-McLain GOLD CGs manual Maintain boiler using schedule below, Service technician

Page 5

GOLD CGs — User’s Information Manual

Maintain boiler using schedule below

Service technician

(covered in CGs Boiler Manual

for use only by a qualified service technician)

Inspect:

Reported problems

Boiler area

Air openings

Flue gas vent system (and air piping)

Pilot and main burner flames

Water piping

Boiler heating surfaces

Burners, base and inlet air box

Condensate drain system

UP

Service:

START-

Inducer motor

 

ANNNUAL

Oiled-bearing circulators

Start-up:

 

 

Perform start-up per manual

 

Check/test:

 

• Gas piping

 

Cold fill and operating pressures

 

Air vents and air elimination

 

Limit controls and cutoffs

 

• Expansion tank

 

Boiler relief valve

Review:

• Review with owner

Owner maintenance

(see following pages for instructions)

 

Check boiler area

Daily

• Check air openings

 

 

 

Check boiler pressure/

 

 

temperature gauge

 

 

 

 

Check boiler interior piping

 

• Check venting system

 

Check air vents

Monthly

Check boiler relief valve

 

 

• Check condensate drain system

 

Check automatic air vents (if

 

 

used)

 

 

 

 

Test low water cutoff (if used)

Periodically

Clean vent termination/air intake

 

 

 

screens

 

 

 

 

Oil inducer motor

Every 6 months

 

 

 

Operate relief valve

 

 

 

End of season • Shut down procedure

Part No. 550-110-261/0999

5

Image 5
Contents Gold CGs Hazard definitions Please read this page firstSTOP!! Read before proceeding Boiler service and maintenanceAir contamination Prevent combustion air contaminationService technician Maintain boiler using schedule belowCheck boiler pressure/ temperature gauge User maintenance proceduresCheck daily Check boiler areaCheck monthly Service every 6 months Service periodicallyEnd-of-season shutdown Follow boiler shutdown procedure① Control module How the boiler worksGold CGs Gas-Fired Induced-Draft Water Boiler Lighting instructions For Your Safety Read Before Operating Symptom Common Causes Possible Corrections Common problems and solutionsSymptom Common Causes Possible Corrections Weil-McLain Blaine Street Michigan City,

GOLD CGs specifications

Weil-McLain has established itself as a leader in the heating industry, and the GOLD CG series is a testament to its commitment to innovation, efficiency, and performance. The GOLD CG is a high-efficiency gas boiler designed for both residential and commercial applications. With its robust construction and intelligent engineering, it provides reliable heating while minimizing fuel consumption.

One of the standout features of the GOLD CG series is its advanced cast iron heat exchanger. This allows for excellent heat retention and optimal efficiency, ensuring that the boiler operates at a high performance level while consuming less energy. The cast iron design not only promotes longevity but also helps in maintaining consistent heating throughout the space.

Another key characteristic of the GOLD CG series is its modulating gas burner. This technology enables the boiler to adjust its output in response to the current heating demands, resulting in improved efficiency and significant energy savings. This modulation reduces short cycling, which can lead to increased wear and tear on the system over time.

The GOLD CG boilers are equipped with a user-friendly control interface, allowing homeowners and property managers to easily monitor and adjust settings. The integrated control system features advanced diagnostics that simplify troubleshooting and maintenance, making it easy to keep the system running smoothly.

Moreover, the GOLD CG series supports a wide range of installation options, including natural gas or propane configurations. This adaptability ensures that it can meet various heating needs, whether in smaller residential settings or larger commercial environments. Additionally, the compact design allows for easy placement in tight spaces, making it a versatile choice for numerous applications.

Environmental considerations are also at the forefront of the GOLD CG series. The boilers are designed to operate efficiently, which helps reduce greenhouse gas emissions. With high Annual Fuel Utilization Efficiency (AFUE) ratings, these boilers meet or exceed most energy efficiency standards, contributing to a more sustainable heating solution.

In summary, the Weil-McLain GOLD CG series stands out for its combination of efficiency, advanced technology, and thoughtful design. With features like a durable cast iron heat exchanger, modulating gas burner technology, and user-friendly controls, it provides reliable heating for a variety of applications while promoting energy conservation and sustainability. Whether for residential or commercial use, the GOLD CG series represents a top-tier choice for modern heating needs.