Weil-McLain 550-141-826/1201 manual Connect Oil Piping, General oil piping requirements

Page 22

Connect Oil Piping

General oil piping requirements:

Location and installation of oil tanks, oil piping and burners must follow:

NFPA 31, Standard for the Installation of Oil-Burning Equipment.

In Canada, CSA B139, Installation of Oil-Burning Equipment.

Local codes and regulations.

Information provided with burner and fuel pump.

If any part of fuel oil tank is above level of burner, an anti-siphon device must be used to prevent flow of oil in case of oil line break.

Support oil lines as required by codes.

Make tank connections with swing joints or copper tubing to prevent breaking in case the tank settles. Make swing joints so they will tighten as tank settles. Non-hardening pipe joint compounds should be used on all threads.

Do not use Teflon tape as an oil pipe sealant. It can cause valves

to fail, creating hazards. Do not use compression fittings.

Underground pipe must be run in a casing to prevent oil leaking into ground or under floor. Check local codes for information.

Oil piping connection at burner:

See FIGURE 16 for recommended connection at burner, allowing burner mounting door to swing open completely for servicing.

Recommended Oil Piping Connection to Burner

FIGURE 16

22

Image 22
Contents This Manual Includes Installation Start-Up Boiler Parts Read This Page First Symbol DefinitionsWhen Calling or Writing About the Boiler Hazard DefinitionsTable of Contents Before selecting boiler location Before Installing BoilerInstallations must comply with Provide clearances around boiler see FigureLay a foundation, if needed Provide air for combustion and ventilationBoiler Foundation Size Table Perform hydrostatic pressure test Install Packaged BoilerPlace boiler Go to page 12 to connect breeching and ventingChange From Back Flue Outlet to Top Flue Outlet Optional Install Non-Packaged Boiler Fiberglass wool and ceramic fiber materialsFlue Collector Hood Install boiler controls Install Packaged and Non-Packaged BoilerInstall jacket sizes 7 through 9 only Control Tapping TableInstall burner also refer to instructions packed with burner General chimney requirements Connect BreechingMinimum Chimney Size Table Connect Breeching General piping information Install pipingConnect Water Piping Diaphragm expansion tank FigureIsolation Piping Multiple Zones Zoning with circulatorsPiping for systems requiring temperatures below 140F Use with refrigeration systems Thermostat wiring Connect WiringGeneral wiring requirements Burner wiringConnect Wiring Connect Wiring General oil piping requirements Connect Oil PipingOil piping connection at burner Tips for water systems Start-UpFill the system To place in operationCheck-Out Procedure Check off steps as completedBurner adjustments for P and a boilers AppendixClose clearance installation Dimension a Parts List DescriptionParts Drawing Dimensions DimensionsIntermediate DIA Ratings WGO Gold OIL Water Boiler Ratings

550-141-826/1201 specifications

The Weil-McLain 550-141-826/1201 is a high-efficiency boiler designed for commercial applications, providing unmatched performance, reliability, and advanced technology features. This model is specifically engineered to cater to a range of heating needs, making it suitable for various settings, such as schools, hospitals, and large commercial spaces.

One of the key features of the Weil-McLain 550-141-826/1201 is its impressive thermal efficiency. With a high AFUE (Annual Fuel Utilization Efficiency) rating, this boiler maximizes energy usage, resulting in lower utility costs for end-users. The efficient performance not only translates to better energy savings but also contributes to a reduced carbon footprint, aligning with modern sustainability goals.

The powerful burner technology incorporated in the Weil-McLain 550-141-826/1201 ensures precise control over the combustion process. This results in consistent heating performance and minimizes emissions, meeting stringent environmental regulations. The unit utilizes advanced modulation technology, which allows the burner to adjust its output according to the demand, providing significant energy savings and enhanced comfort.

Another standout characteristic of this boiler is its robust construction. Built with high-quality materials, the Weil-McLain 550-141-826/1201 is designed to endure demanding conditions, ensuring longevity and reduced maintenance needs. The boiler features a durable heat exchanger, which optimizes thermal transfer efficiency while resisting corrosion and thermal stress.

The user-friendly controls and monitoring systems enhance the operational experience, allowing for easy adjustments and status checks. The integrated diagnostic capabilities provide valuable insights for troubleshooting, making maintenance straightforward and reducing downtime.

Furthermore, the versatility of the Weil-McLain 550-141-826/1201 allows for multiple installation configurations, accommodating different system requirements and space limitations. Its compact design makes it an ideal choice for facilities where space is a premium.

In summary, the Weil-McLain 550-141-826/1201 stands out in the commercial boiler market with its high efficiency, innovative burner technology, robust construction, user-friendly controls, and versatile installation options. This model exemplifies Weil-McLain's commitment to energy-efficient heating solutions, setting a benchmark for performance and reliability in the industry.