Installation

(Continued)

4.Do not set the pump directly on dirt, mud or sand. This will cause the inlet to clog. Set pump on a hard surface in water.

Operation

Do not touch pump, pump

motor, water or discharge piping when the pump is connected to electrical power. Do not handle a pump or pump motor with wet hands or when standing in water or on a wet or damp surface. Never touch the pump or discharge piping when unit is operating or fails to operate. Always disconnect the pump power cord before handling.

Risk of electrical shock! This pump is supplied with a grounding conductor and grounding type

attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock. Never cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump dangerous to operate.

1.Plug unit into a grounded 120 volt AC power outlet. The unit will operate continuously whether partly or fully submerged.

2.On a flat surface, the pump will remove water down to 1/8” of the pumping surface. Shut off pump immediately if unit has been operating and suddenly no water comes out of discharge hose. The water level is probably very low and the pump has lost prime. Use a mop or squeegee to remove remaining water.

3.Never allow pump to run dry. Pump depends on water for lubrication. Do not operate unit unless pump is submerged in water. Dry running (pump not pumping water) will damage the pump and cause pump failure.

Maintenance

Always disconnect the electric supply

before attempting to install, service, relocate or perform any maintenance. Failure to do so could result in fatal electrical shock.

Minimal service is required for this pump. If pump should fail to operate, perform the following troubleshooting guidelines.

1.The motor housing of the pump is completely sealed and requires no service. Disassembly of the motor housing or alteration of the power cord could result in fatal electrical shock and will void the warranty.

2.Verify the pump is operating correctly.

a.Disconnect the pump from the power source.

b.Disconnect the discharge hose from the pump.

c.Immerse the pump in a bucket or tub of water.

d.Plug the power cord into a grounded 120 volt AC power outlet. If the pump operates correctly proceed to step #3. If pump does not operate, unplug the power cord and proceed to maintenance guideline #4.

3.Verify the discharge hose is correctly installed.

a.Connect hose to another water source such as a faucet. If water flows through the hose, proceed to 3b. If water is restricted, verify the discharge hose is unwound.

Remove all kinks, bends or obstructions in the hose.

b.Verify pumping height does not exceed 14 ft. (see Figure 5). If pumping height is greater than 14 ft, this pump will not work.

14 Ft.

Max

Water Level

Figure 5

4.Verify the impeller is free to rotate.

a.Disconnect the pump from the power source.

b.Remove the three (3) screws securing the screen to the base.

c.Hold the pump by the handle with one hand. Grab the screen with the other hand and pull the screen away from the base.

d.Hold the motor housing upside down and rotate the impeller by hand. Clean the base and impeller side of motor housing with tap water.

e.Install the screen to the base. Screw the screen and base together.

f.Plug the power cord into a grounded 120 volt AC power outlet. The pump should operate.

5.Rinse the impeller and base with tap water after each use.

www.waynepumps.com

2

Image 2
Contents Description InstallationSubmersible Utility Pump GFU SeriesMaintenance OperationDéballage Pompe Immergée Tout UsageSérie GFU Information de Sécurité Très ImportanteFonctionnement EntretienInstalación Bomba Sumergible de Uso GeneralDescripción Serie GFUFuncionamiento MantenimientoNotas Limited Warranty

320702-001, GFU Series specifications

The Wayne 320702-001, part of the GFU Series, represents a significant advancement in fueling technologies and equipment, tailored specifically for high-performance fueling operations. Designed for both efficiency and durability, this innovative unit provides a comprehensive solution for various fueling applications, making it a preferred choice for businesses in the petroleum industry.

One of the standout features of the Wayne 320702-001 is its user-friendly interface, which incorporates advanced digital controls. These controls not only simplify the fueling process but also enhance operational efficiency. Users can monitor fuel flow and control operations from a centralized display, allowing for real-time adjustments and performance tracking.

The GFU series showcases cutting-edge technology such as high-speed pumps that facilitate quick fueling capabilities, significantly reducing wait times for customers. This is particularly beneficial in high-traffic areas where efficiency directly impacts service quality and customer satisfaction. Additionally, the Wayne 320702-001 is engineered for compatibility with various fuel types, including gasoline, diesel, and alternative fuels, ensuring versatility across different fueling stations.

Durability is another hallmark of the Wayne 320702-001. Constructed with robust materials and designed to withstand harsh environmental conditions, this unit promises longevity and minimal maintenance. Its weather-resistant design ensures that it operates smoothly regardless of external conditions, making it an ideal investment for businesses seeking reliability.

Safety features are integral to the design of the Wayne 320702-001. It includes automatic shut-off systems and leak detection technologies that prioritize user safety and environmental protection. These features help mitigate risks associated with fuel dispensing, allowing operators to maintain compliance with industry regulations.

In summary, the Wayne 320702-001, GFU Series, is a powerful fueling solution that combines efficiency, durability, and safety. Its advanced digital controls, high-speed pumping capabilities, and compatibility with multiple fuel types make it a versatile choice for fueling stations. With a focus on user-friendly operation and robust construction, this unit is poised to meet the demands of modern fueling operations while ensuring safety and customer satisfaction. For businesses in the petroleum sector, investing in the Wayne 320702-001 represents a step towards enhanced operational efficiency and reliability.