Wayne 320702-001 warranty Submersible Utility Pump, Description, Installation, GFU Series

Page 1

Operating Instruction and Parts Manual

GFU Series

 

 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Submersible

Utility Pump

Description

This portable, submersible utility pump is designed for non-automatic use in water. The unit is equipped with a 10 ft. 3-prong grounding type power cord. The pump’s outlet fitting is designed for convenient discharge through a garden hose. This pump is not designed for ponds or fountains.

Unpacking

Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death.

Very Important Safety Information

1.Wear safety glasses at all times when working with pumps.

2.It is strongly

recommended that this unit is plugged into a Ground Fault Circuit Interrupter (GFCI) (See

Figure 1). Consult a local electrician for installation and availability.

Grounding blade

Figure 1

3.Do not use the power cord or discharge hose to carry or hang the pump, always use the handle.

Female end of garden hose

Figure 2

2.To reduce leakage between the pump and the hose, place a hose washer (not included) on the hose fitting prior to installing the hose to the pump (see Figure 3).

Hose Washer (not included)

Always follow these safety guidelines to avoid bodily injury or property damage.

Do not use to

pump flammable or explosive fluids such as gasoline, fuel oil, kerosene,

etc. Do not use in flammable and/or explosive atmospheres. Pump should be used only to pump clear water. Personal injury and/or property damage could result.

Risk of electric

shock! This pump has not been investigated for use in swimming pool areas.

Never place pump in pool while people are in the water.

Do not handle pump with wet

hands or when standing in water or on a damp surface.

Installation

Always disconnect the electric supply

before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and tag in open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock.

Important: This unit is not designed for use in septic tanks or underground vaults to pump raw sewage or effluents. Never use in hazardous or explosive locations.

1.This pump has been designed to attach to a standard garden hose. Thread the female end of the garden hose to the male discharge on the pump (see Figure 2) .

Figure 3

3.For best performance, unwind hose before starting the pump. Remove kinks or bends in the hose to allow unit to pump unrestricted (see Figure 4).

Correct

Incorrect

Figure 4

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2004 Wayne Water Systems

For parts, product & service information

320702-001 3/04

visit www.waynepumps.com

1

Image 1
Contents Submersible Utility Pump InstallationDescription GFU SeriesOperation MaintenanceSérie GFU Pompe Immergée Tout UsageDéballage Information de Sécurité Très ImportanteEntretien FonctionnementDescripción Bomba Sumergible de Uso GeneralInstalación Serie GFUMantenimiento FuncionamientoNotas Limited Warranty

320702-001, GFU Series specifications

The Wayne 320702-001, part of the GFU Series, represents a significant advancement in fueling technologies and equipment, tailored specifically for high-performance fueling operations. Designed for both efficiency and durability, this innovative unit provides a comprehensive solution for various fueling applications, making it a preferred choice for businesses in the petroleum industry.

One of the standout features of the Wayne 320702-001 is its user-friendly interface, which incorporates advanced digital controls. These controls not only simplify the fueling process but also enhance operational efficiency. Users can monitor fuel flow and control operations from a centralized display, allowing for real-time adjustments and performance tracking.

The GFU series showcases cutting-edge technology such as high-speed pumps that facilitate quick fueling capabilities, significantly reducing wait times for customers. This is particularly beneficial in high-traffic areas where efficiency directly impacts service quality and customer satisfaction. Additionally, the Wayne 320702-001 is engineered for compatibility with various fuel types, including gasoline, diesel, and alternative fuels, ensuring versatility across different fueling stations.

Durability is another hallmark of the Wayne 320702-001. Constructed with robust materials and designed to withstand harsh environmental conditions, this unit promises longevity and minimal maintenance. Its weather-resistant design ensures that it operates smoothly regardless of external conditions, making it an ideal investment for businesses seeking reliability.

Safety features are integral to the design of the Wayne 320702-001. It includes automatic shut-off systems and leak detection technologies that prioritize user safety and environmental protection. These features help mitigate risks associated with fuel dispensing, allowing operators to maintain compliance with industry regulations.

In summary, the Wayne 320702-001, GFU Series, is a powerful fueling solution that combines efficiency, durability, and safety. Its advanced digital controls, high-speed pumping capabilities, and compatibility with multiple fuel types make it a versatile choice for fueling stations. With a focus on user-friendly operation and robust construction, this unit is poised to meet the demands of modern fueling operations while ensuring safety and customer satisfaction. For businesses in the petroleum sector, investing in the Wayne 320702-001 represents a step towards enhanced operational efficiency and reliability.