Quasar HQ-2081TH manual How to Install the Unit, Window Requirements

Page 9

INSTALLATION

How to Install the Unit

1.To prevent vibration and noise, make sure the unit is installed securely and firmly

2.Install the unit where the sunlight does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 28cm (11") and there should be no obstacles, such as a fence or wall, within 50.8cm (20") from the back of the cabinet because it will prevent heat radiation of the condenser.

Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

Cooled air

76.2cm (30")~ 152.4cm (60")

Fence

Awning

Heat radiation

About 12.7mm (1/2")

Over 50.8cm (20")

CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.

4.Install the unit a little slanted so the back is slightly lower than the front (about 12.7cm (1/2")).

This will force condensed water to flow to the outside.

5.Install the unit with the bottom about 76.2cm (30")~152.4cm (60") above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

Features and

This unit is designed for installation in standard double hung windows with actual opening widths from 55.88cm (22") to 91.44cm (36").

The top and bottom window sash must open sufficiently to allow a clear vertical opening of 38cm (15") from the bottom of the upper sash to the window stool.

55.8cm (22") to 91.44cm (36")

38cm (15") min

Stool

(With frame curtain)

Interior wall 47cm (181/2") min.

(Without frame curtain)

Offset

12.7mm (1/2") to 31.8mm (11/4")

Sill

Exterior

Installation

9

Image 9
Contents Installation and Operating Instructions For Your Records Be sure not to do this Be sure to follow the instructions Safety PrecautionsDegrade the insulation. It may Cause an electric shock Controls About the Controls on the Air ConditionerFor Normal Cooling For Maximum CoolingHow to Secure the Drain Pipe VentilationAir Direction Air Filter Cleaning Care and MaintenanceFeatures FeaturesWindow Requirements How to Install the UnitInstallation Kit Contents Suggested Tool Requirements Cabinet Installation Bottom PAN USE of Extension Cords Electrical DataPlease Read Carefully Electrical SafetyBefore you call for service Normal OperationAbnormal Operation Para SU Informacion Precauciones Importantes de Seguridad Precaucion Controles Instruccionnes de FuncionamientoPara UN Enfriamiento Normal Para UN Enfriamiento MaximoComo Installar el Tubo de Desagüe VentilaciónComo controlar la direccion del aire Limpieza de filtro de Aire Cuidado y MantenimientoCaracterísticas CaracterísticasInstrucciones de Instalación Elija el major lugarRequistios de ventana Preparacion DEL Chasis Requisitos de las herra mientas sugeridasNota Instalación del GabineteTipo C Conrdon De Alimentacion TornilloTipo a Tira de Goma Neas de 15A, 125V AC Datos ElectricosImportante Informacion ElectricaAntes de avisar al Servicio Técnico Operación normalOperación anormal Product Specification Especificiones DEL Producto Nota Panasonic Room Air Conditioner