Paradox Hellas S.A DGP2-648BL, DGP2-641BL Option 6 Add Tolerance Window to Schedule, 16 EVO96

Page 19

Option [6]: Add Tolerance Window to Schedule

When option [6] is ON, the Schedule Tolerance Window feature is enabled. This feature extends a user’s scheduled access period through an Access Control door by the amount programmed by your installer. For example, if the user’s assigned schedule for the door is Monday to Friday from 9:00 a.m. to 5:00 p.m., and your installer sets the “Tolerance Window” at one hour, the user with the “Schedule Tolerance Window” enabled will be able to enter and exit one hour before and after their scheduled time for that door.

Option [7]: Code Follows Schedule

When option [7] is ON, users can use their access codes only during their scheduled hours assigned in step 8 in section 6.6.1 on page 13. When the option is OFF, users can use their access codes at any time.

Option [8]: Card to Unlock and Code to Disarm

Option [8] functions only if option [2] in section 6.8 is OFF. When option [8] is ON, a user can use an Access Control card to unlock an armed Access Control door, however the user must enter a user access code to disarm the armed area. When option [8] is OFF, a user can gain access to an Access Control door only if the door’s area(s) is already disarmed.

For option [8] to function in the ON position, option [5] “Arm Only” in the User Options must be disabled (refer to section 6.7 on page 14).

16 EVO96

Image 19
Contents EVO96 Page Table of Contents User’s Manual IntroductionAuditory Feedback Beep Tones Basic OperationEVO96 Icons Display and Functionality Visual FeedbackLight Function Display Status LCD Icon LED Confidential ModeArea Display Partitioned SystemArming Bypass Programming Keyswitch ArmingOne-Touch Buttons Timed Auto-Arming Auto-ArmingNo Movement Auto-Arming Disarming Alarm Memory DisplayCopy User Options Access CodesSystem Master Code Default Find Next Free UserSpecial Function Keys Stay = Insert Space User LabelsKeypad Buttons Key Press Key OnceProgramming User Access Codes Deleting User Access Codes12 EVO96 Area Programming User Access CodesOption 3 Duress Programming User Access Codes with the DGP2-648BLOptions 1 and 2 Master Feature User OptionsOptions 4 and 5 Arming with Card Access Control User OptionsOption 4 Bypass Option 5 Arm Only16 EVO96 Option 6 Add Tolerance Window to ScheduleArming with Card Using Access ControlEntering & Exiting Arming and Disarming with Card18 EVO96 How Access Control WorksTrouble Display Trouble Display20 EVO96 Group 7 Zone FaultEvent Record Display Group 8 Clock LossKeypad Settings Additional FeaturesProgrammable Outputs PGMs 22 EVO96 Panic AlarmsSet Time & Date Programming Chime ZonesQuick Function Buttons Panic Alarm TypesButtons to be pressed and held Simultaneously 10.3 System Maintenance Testing and MaintenanceBurglar Alarm Testing 10.2 Fire Alarm TestingStandard Fire Zone Fire and Burglar AlarmsDelayed Fire Zone Fire Safety Tips26 EVO96 Burglar AlarmMinimizing Home Fire Hazards Home Fire Warning SystemAppendix 1 Hebrew Special Characters 28 EVO96 Appendix 2 Russian Special CharactersKey Press key once Press key twice Press key three Times Appendix 3 Greek Special CharactersIndex Access Control, see Access Control User Options Warranty

EVO96, DGP2-641BL, DGP2-648BL, DGP2-640, DGP2-641RB specifications

Paradox Hellas S.A. is a prominent manufacturer of advanced security systems, and their product line includes an impressive range of alarm panels and modules. Among their offerings, the DGP2-641RB, DGP2-640, DGP2-648BL, DGP2-641BL, and the EVO96 stand out as key components with unique features and capabilities tailored to meet diverse security needs.

The DGP2-641RB is a versatile control panel that integrates seamlessly with various peripherals and detectors. This model is designed for both residential and commercial applications, providing outstanding performance through its intuitive user interface. It supports advanced networking options that facilitate easy installation and configuration, ensuring a hassle-free setup process.

The DGP2-640 is acclaimed for its robust reliability and efficiency. Featuring an advanced power management system, this control panel has the ability to handle a larger number of zones, making it ideal for extensive security systems. Additionally, it offers event logging capabilities, allowing users to review security events that have occurred, enhancing accountability and awareness.

Moving on to the DGP2-648BL, this model is engineered with customization in mind. Its multiple zone programming options cater to a wide array of environments, and the sleek black finish adds a modern touch to any installation. The DGP2-648BL is also designed to be compatible with Paradox's full range of wireless devices, ensuring that installation is not only flexible but also efficient.

The DGP2-641BL variant, similarly, focuses on delivering a mix of reliability and aesthetics. It sports an elegant design while retaining high functionality, offering users a satisfying blend of security and style. This model’s user-friendly interface provides easy access to all settings and options, making it a favorite among both technicians and end-users.

Finally, the EVO96 represents the pinnacle of innovation within Paradox Hellas S.A's lineup. This control panel is equipped with cutting-edge technologies, allowing for an unprecedented level of control and automation in security management. It boasts a high-capacity memory that stores extensive user data, facilitating tailored alarm configurations. The EVO96 is particularly noted for its capacity to integrate with smart home technologies, creating a comprehensive security ecosystem.

With these models, Paradox Hellas S.A. continues to push the boundaries of security technology, ensuring users have access to flexible, reliable, and innovative solutions that safeguard their properties.