Paradox Hellas S.A DGP2-648BL Set Time & Date, Programming Chime Zones, Panic Alarms, 22 EVO96

Page 25

LED

Figure 8: Modifying illumination settings on the DGP2-648BL

1.

Enter your [ACCESS CODE]. Your keypad will emit

 

 

 

a Confirmation Beep. The ACCESS action light will

 

 

flash.

 

2.

Press the [6] key. Your keypad will emit a

 

 

Confirmation Beep, the Prg action light will

 

 

illuminate and the numerical light for the current

 

 

setting will illuminate.

 

3.

Use the [U] and [V] keys to increase or

 

 

decrease the illumination. The range is between

 

 

numerical light 1 to 8 (1 being the lowest and 8,

 

 

the brightest).

 

4.

Press the [ENTER] key to save and exit.

LCD ICON

LED

LCD ICON LED

LCD ICON LED

9.3Set Time & Date

To reset the time and date:

1.Enter your [ACCESS CODE] and press the [TRBL] button or the [] key.

2.Press the [8] button.

3.To change the time, place the cursor under the number you want to change by using the [S] button and enter the time according to a 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).

4.To change the date, place the cursor under the number you want to change and enter the correct date according to year/month/day. On the DGP2-640 keypad, you will have to press the [ ] key to not change an element of the date.

5.Press the [ENTER] button to save and exit.

On the DGP2-648BL keypad, follow this procedure:

1.Enter your [ACCESS CODE] and press the [TRBL] button or the [] key.

2.Press the [8] button.

3.Enter the hour and minutes according to the 24-hour clock (i.e. 9AM is 09:00 and 9PM is 21:00).

4.Enter the correct date according to yyyy/mm/dd.

5.Press [CLEAR].

9.4Programming Chime Zones

You can program the keypad to emit a rapid, intermittent beep tone whenever designated zones are opened or only when opened between certain hours. These zones are referred to as Chime Zones. Your installer can also program your Chime zones to beep upon closure.

How do I program chime zones?

1.Enter your [ACCESS CODE].

2.Press the [9] key.

3.Press the [1] key to chime a zone. Enter the number corresponding to the zone to be chimed, or use the [S] and [T] buttons to scroll the list of zones. Press the [ACC] button to chime or unchime the zone that appears on the screen. Press [ENTER] to save.

OR

Press the [2] button to set the time period a chimed zone will beep. Enter the time that the chimed zone(s) will start beeping when opened (HH:MM). Enter the time that the chimed zone(s) will stop beeping when opened (HH:MM).

4.Press [CLEAR] to exit chime programming.

9.5Panic Alarms

Your system can be programmed to send an alarm to your monitoring station to request help from the police, a medical facility, the fire department, or anyone you wish when you press a predetermined combination of buttons. To generate a panic alarm, simultaneously

22 EVO96

Image 25
Contents EVO96 Page Table of Contents User’s Manual IntroductionAuditory Feedback Beep Tones Basic OperationEVO96 Icons Display and Functionality Visual FeedbackLight Function Display Status LCD Icon LED Confidential ModeArea Display Partitioned SystemArming Bypass Programming Keyswitch ArmingOne-Touch Buttons Timed Auto-Arming Auto-ArmingNo Movement Auto-Arming Disarming Alarm Memory DisplaySystem Master Code Default Access CodesFind Next Free User Copy User OptionsKeypad Buttons User LabelsKey Press Key Once Special Function Keys Stay = Insert SpaceProgramming User Access Codes Deleting User Access Codes12 EVO96 Area Programming User Access CodesOptions 1 and 2 Master Feature Programming User Access Codes with the DGP2-648BLUser Options Option 3 DuressOption 4 Bypass Access Control User OptionsOption 5 Arm Only Options 4 and 5 Arming with Card16 EVO96 Option 6 Add Tolerance Window to ScheduleEntering & Exiting Using Access ControlArming and Disarming with Card Arming with Card18 EVO96 How Access Control WorksTrouble Display Trouble DisplayEvent Record Display Group 7 Zone FaultGroup 8 Clock Loss 20 EVO96Keypad Settings Additional FeaturesProgrammable Outputs PGMs Set Time & Date Panic AlarmsProgramming Chime Zones 22 EVO96Quick Function Buttons Panic Alarm TypesButtons to be pressed and held Simultaneously Burglar Alarm Testing Testing and Maintenance10.2 Fire Alarm Testing 10.3 System MaintenanceDelayed Fire Zone Fire and Burglar AlarmsFire Safety Tips Standard Fire ZoneMinimizing Home Fire Hazards Burglar AlarmHome Fire Warning System 26 EVO96Appendix 1 Hebrew Special Characters 28 EVO96 Appendix 2 Russian Special CharactersKey Press key once Press key twice Press key three Times Appendix 3 Greek Special CharactersIndex Access Control, see Access Control User Options Warranty

EVO96, DGP2-641BL, DGP2-648BL, DGP2-640, DGP2-641RB specifications

Paradox Hellas S.A. is a prominent manufacturer of advanced security systems, and their product line includes an impressive range of alarm panels and modules. Among their offerings, the DGP2-641RB, DGP2-640, DGP2-648BL, DGP2-641BL, and the EVO96 stand out as key components with unique features and capabilities tailored to meet diverse security needs.

The DGP2-641RB is a versatile control panel that integrates seamlessly with various peripherals and detectors. This model is designed for both residential and commercial applications, providing outstanding performance through its intuitive user interface. It supports advanced networking options that facilitate easy installation and configuration, ensuring a hassle-free setup process.

The DGP2-640 is acclaimed for its robust reliability and efficiency. Featuring an advanced power management system, this control panel has the ability to handle a larger number of zones, making it ideal for extensive security systems. Additionally, it offers event logging capabilities, allowing users to review security events that have occurred, enhancing accountability and awareness.

Moving on to the DGP2-648BL, this model is engineered with customization in mind. Its multiple zone programming options cater to a wide array of environments, and the sleek black finish adds a modern touch to any installation. The DGP2-648BL is also designed to be compatible with Paradox's full range of wireless devices, ensuring that installation is not only flexible but also efficient.

The DGP2-641BL variant, similarly, focuses on delivering a mix of reliability and aesthetics. It sports an elegant design while retaining high functionality, offering users a satisfying blend of security and style. This model’s user-friendly interface provides easy access to all settings and options, making it a favorite among both technicians and end-users.

Finally, the EVO96 represents the pinnacle of innovation within Paradox Hellas S.A's lineup. This control panel is equipped with cutting-edge technologies, allowing for an unprecedented level of control and automation in security management. It boasts a high-capacity memory that stores extensive user data, facilitating tailored alarm configurations. The EVO96 is particularly noted for its capacity to integrate with smart home technologies, creating a comprehensive security ecosystem.

With these models, Paradox Hellas S.A. continues to push the boundaries of security technology, ensuring users have access to flexible, reliable, and innovative solutions that safeguard their properties.