Paradox Hellas S.A DGP2-641RB Fire and Burglar Alarms, Standard Fire Zone, Delayed Fire Zone

Page 28

LCD ICON LED

LCD ICON LED

11.0Fire and Burglar Alarms

11.1Standard Fire Zone

During a fire alarm, the bell/siren emits an intermittent sound (BEEP-BEEP-BEEP) until silenced or reset. If the zone is a Standard Fire Zone, your system can immediately send an alert to your monitoring station.

To disarm a false alarm:

1.Enter your [ACCESS CODE] on the keypad.

2.Call your monitoring station quickly to advise them of the false alarm.

The Fire Zone may reset itself once the problem has cleared. If it does not, simultaneously press and hold the [CLEAR] and [ENTER] buttons for two seconds.

11.2 Delayed Fire Zone

If the zone is a Delayed Fire Zone, there is an automatic delay before your system contacts your monitoring station. Refer to Figure 9 on page 26 to prevent unnecessary reporting of false alarms.

If the fire alarm is accidentally triggered:

1.Press the [CLEAR] button or the [] key within 30 seconds of the alarm.

2.Clear the problem from the area (i.e. clear the smoke from around the smoke detector).

3.If the problem remains after 90 seconds, the alarm will sound again. Press [CLEAR] again.

4.The system will delay reporting the alert for another 30 seconds.

If you are unable to cancel the false alarm, your system will send an alert. Call your monitoring station to advise them of the false alarm.

The Fire Zone may reset itself once the smoke has cleared. If it does not, simultaneously press and hold the [CLEAR] and [ENTER] buttons for two seconds or speak to your installer.

11.3 Fire Safety Tips

How should you prepare in case of a fire in your home or business?

Remind everyone to escape first, and then call for help.

Develop a fire escape plan and designate a meeting place outside.

Practice the escape plan frequently.

Plan two ways to escape from every room, if possible.

Practice feeling the way out with eyes closed.

Instruct everyone never to stand up during a fire, always crawl under the smoke and keep mouths covered.

Instruct everyone never to return to a burning building for any reason; it may cost them their life.

Check smoke alarms regularly. Working smoke alarms dramatically increase everyone's chances of surviving a fire.

User’s Manual 25

Image 28
Contents EVO96 Page Table of Contents Introduction User’s ManualAuditory Feedback Beep Tones Basic OperationEVO96 Icons Display and Functionality Visual FeedbackLight Function Display Status Confidential Mode LCD Icon LEDPartitioned System Area DisplayArming Bypass Programming Keyswitch ArmingOne-Touch Buttons Timed Auto-Arming Auto-ArmingNo Movement Auto-Arming Alarm Memory Display DisarmingAccess Codes System Master Code DefaultFind Next Free User Copy User OptionsUser Labels Keypad ButtonsKey Press Key Once Special Function Keys Stay = Insert SpaceProgramming User Access Codes Deleting User Access Codes12 EVO96 Programming User Access Codes AreaProgramming User Access Codes with the DGP2-648BL Options 1 and 2 Master FeatureUser Options Option 3 DuressAccess Control User Options Option 4 BypassOption 5 Arm Only Options 4 and 5 Arming with CardOption 6 Add Tolerance Window to Schedule 16 EVO96Using Access Control Entering & ExitingArming and Disarming with Card Arming with CardHow Access Control Works 18 EVO96Trouble Display Trouble DisplayGroup 7 Zone Fault Event Record DisplayGroup 8 Clock Loss 20 EVO96Keypad Settings Additional FeaturesProgrammable Outputs PGMs Panic Alarms Set Time & DateProgramming Chime Zones 22 EVO96Quick Function Buttons Panic Alarm TypesButtons to be pressed and held Simultaneously Testing and Maintenance Burglar Alarm Testing10.2 Fire Alarm Testing 10.3 System MaintenanceFire and Burglar Alarms Delayed Fire ZoneFire Safety Tips Standard Fire ZoneBurglar Alarm Minimizing Home Fire HazardsHome Fire Warning System 26 EVO96Appendix 1 Hebrew Special Characters Appendix 2 Russian Special Characters 28 EVO96Appendix 3 Greek Special Characters Key Press key once Press key twice Press key three TimesIndex Access Control, see Access Control User Options Warranty

EVO96, DGP2-641BL, DGP2-648BL, DGP2-640, DGP2-641RB specifications

Paradox Hellas S.A. is a prominent manufacturer of advanced security systems, and their product line includes an impressive range of alarm panels and modules. Among their offerings, the DGP2-641RB, DGP2-640, DGP2-648BL, DGP2-641BL, and the EVO96 stand out as key components with unique features and capabilities tailored to meet diverse security needs.

The DGP2-641RB is a versatile control panel that integrates seamlessly with various peripherals and detectors. This model is designed for both residential and commercial applications, providing outstanding performance through its intuitive user interface. It supports advanced networking options that facilitate easy installation and configuration, ensuring a hassle-free setup process.

The DGP2-640 is acclaimed for its robust reliability and efficiency. Featuring an advanced power management system, this control panel has the ability to handle a larger number of zones, making it ideal for extensive security systems. Additionally, it offers event logging capabilities, allowing users to review security events that have occurred, enhancing accountability and awareness.

Moving on to the DGP2-648BL, this model is engineered with customization in mind. Its multiple zone programming options cater to a wide array of environments, and the sleek black finish adds a modern touch to any installation. The DGP2-648BL is also designed to be compatible with Paradox's full range of wireless devices, ensuring that installation is not only flexible but also efficient.

The DGP2-641BL variant, similarly, focuses on delivering a mix of reliability and aesthetics. It sports an elegant design while retaining high functionality, offering users a satisfying blend of security and style. This model’s user-friendly interface provides easy access to all settings and options, making it a favorite among both technicians and end-users.

Finally, the EVO96 represents the pinnacle of innovation within Paradox Hellas S.A's lineup. This control panel is equipped with cutting-edge technologies, allowing for an unprecedented level of control and automation in security management. It boasts a high-capacity memory that stores extensive user data, facilitating tailored alarm configurations. The EVO96 is particularly noted for its capacity to integrate with smart home technologies, creating a comprehensive security ecosystem.

With these models, Paradox Hellas S.A. continues to push the boundaries of security technology, ensuring users have access to flexible, reliable, and innovative solutions that safeguard their properties.