Nexus 21 S, 3, PF-0 installation manual Introduction, Installation, Installing the Pumpset

Page 1

INTRODUCTION

Nexus Pumpset PF-0,3 /S

Installation Manual

Thank you for choosing a Nexus Pumpset. Through this manual we will help you install your new Nexus product. Please read through this manual carefully before starting your installation.

1 Introduction

The Pumpset should be connected to the boat's hydraulic steering system according to figure 1. The Pumpset motor only operates when carrying out a rudder command. When the boat is on course, the Pumpset stops. A variable speed motor drive adjusts optimal rudder speed and provides for minimum power consumption and maximum rudder posi- tioning accuracy. Most existing multiple station steering systems have lock valves, which automatically isolate stations from each other and from the autopilot Pumpset. A lock valve should be installed so that the helm can be isolated.

2 Installation

Note! Because most installations differ, the following items are not supplied and need to be sourced or made locally: Support bracket for Pumpset, 4 mounting screws and wash- ers, hydraulic fittings and piping.

2.1 Installing the Pumpset

The Pumpset is splashproof and should be mounted in a cool dry location, which mini- mises hydraulic piping and wiring runs. The enclosed figure indicates the piping required for the different hydraulic steering systems. The Pumpset may be mounted horizontally (Pumpset feet down) or vertically with the pump positioned above the motor. Be certain to leave adequate space to access the bleed screw. Four screws and washers are required to hold the Pumpset resilient feet to the mounting surface. In any case be sure, to mount the pumpset itself or, if not possible, the pumpset-reservoir at the highest position of the hydraulic system.

2.2 Installing hydraulic fittings and piping

It is recommended that all fittings to be installed are aligned with the Pumpset before it is mounted. The type of hydraulic fittings required i.e., straight or 90° angle, will depend on the mounting position of the Pumpset and the location of piping.

Recommended size for all connections are hydraulic hoses and fittings with an inner di- ameter of 8 mm (0.32”) minimum to reduce the drag.

Use only hydraulic hoses, suitable for a working pressure of 1,000 PSI (70bar). The hy- draulic fittings selected must be suitable for the hydraulic hoses size used.

Note! All ports on the Pumpset are 1/4" NPT.

Pipe sealant or teflon tape is required on all male pipe thread fittings. Be certain to keep the sealant or tape at least two threads away from the starting threads to prevent threaded tape or sealant from contaminating the system.

Image 1
Contents Installing the Pumpset InstallationInstalling hydraulic fittings and piping IntroductionNstallation Pumpset oil filling Dockside testingConnec- tion Specifications Maintenance and inspection scheduleGeneral Warranty