6Commissioning, start-up / Shutdown

Instructions for boiler feed applications

Limit values for boiler feed water and condensate when using cast iron pump parts: pH value ￿ 9.0 (target: ￿ 9.3)

O2 content 0.02 ppm.

These values must be ensured under all operating conditions before entry into the pump. Max. percentage of fresh water: 25%.

Water treatment shall be in accordance with VdTÜV guidelines for feed and boiler water in steam plants of up to 64 bar.

The penetration of air into the system must be avoided by all means.

6.1Commissioning

Caution

Before starting up the pump make sure that the

 

following requirements have been met:

-The quality of the concrete foundation is in compliance with the applicable regulations.

-The tolerances stipulated for mounting the unit on the foundation, for shims and alignment have been complied with.

-The pipelines have been connected without warping the pump nozzles.

-Electrical connection and relay settings correspond to the motor rating and comply with the applicable regulations.

-All hydraulic, electrical and mechanical protection devices have been set.

-The pump has been fully primed with the fluid to be pumped.

-The unit’s direction of rotation corresponds to the rotation arrows.

-All connections are leak-free.

Caution

For installation without foundation (e.g. on spring

 

elements) care must be taken that all movements

of the pump

unit can be compensated, e.g. by fitting expansion

joints in the discharge and suction lines.

6.1.1 Lubricants Grease-lubricated bearings

The grease-lubricated bearings are packed with grease at the factory (see section 7.2.2).

Oil lubricated bearings

Fill oil of ISO VG 46 quality into the bearing cover (see section 7.2.2).

6.1.2Priming the pump and checks to be carried out

Before each start-up, the pump and the suction line must be completely vented and primed with the fluid to be pumped. The pump has several plugged holes for venting; adequate venting devices can be used in the pipelines. The shut-off valve in the suction or feed line must be fully open.

Fully open all auxiliary connections provided and check the throughflow.

Open shut-off valve ”C” in the vacuum balance line (if any), and close the vacuum-tight shut-off valve ”E” (see 5.4.1).

Caution

Dry running will lead to increased wear on the unit

 

and may eventually damage the pump !

If the discharge line is equipped with an automatic check valve, open the minimum flow valve and secure against inadvertent closing.

Exceptions:

-If there is not enough back pressure in the line prior to start-up, the shut-off element must be closed before pump start-up.

-On pumps fitted with a mechanical seal, the mechanical seal will leak only slightly, i.e. practically invisibly (vapour) during operation. It is maintenance-free.

-If the pump is equipped with a gland packing, leakage during operation is normal (see 6.1.6).

Special notes regarding cooled mechanical seals (seal code 64)

-If the pump is equipped with a cooled mechanical seal, vent the seal chamber by opening the screwed plug 903.11 by a quarter turn, then re-tighten.

Pump sizes 32 to 100

Fig. 14

Pump sizes 125 and 150

Fig. 15

Caution The seal chamber has to be vented when the pump is in cold condition before start-up. When venting in hot condition, steam will escape at the vent plug

during the venting process (risk of scalding!) Should it not be possible to avoid opening the seal chamber in hot condition, due to the situation in the plant, a pipe with valve (not included in KSB’s scope of supply) must be installed at the vent hole, in order to lead the steam escaping during venting to another place where there is no danger of scalding. Make sure that this valve cannot be opened during operation.

11

Image 11
Contents Works No Type series High-pressure pumps in ring-section designOperating instructions 1777.8/7-10 G3 Multitec Contents Multitec Index Section Adjusting dimensions for couplingMultitec General SafetyTransport, storage MultitecDescription Product AccessoriesClose-coupled pumps Multitec Installation at siteFoundation / Checks to be carried out prior to installation Installing the pump/unit100 120 Nm Aligning the pump / drive Coupling guardBe tightened to the following torques Tightening torque Thread Strength Drive Non-drive EndProtection against foreign matter Connecting the pipingMax. permissible pipeline forces material codes 10, 11, 12 Max. permissible pipeline forces material codes 20 toChecking the direction of rotation Connection to power supplySetting the time relay Vacuum balance lineMultitec Commissioning, start-up / Shutdown Gland packing Temperature of the fluid pumpedStart-up ShutdownDensity of fluid pumped Switching frequencyReturning to service after storage Minimum flowsPump Multitec Servicing / maintenanceBearings and lubrication General instructionsCoupling Oil quality / Oil changeMotor Shaft seal Mechanical sealRadial suction nozzle Dismantling the bearingsDismantling the non-drive-end bearings Plain bearing Axial suction nozzleGrease lubrication Grease lubrication figsOil lubrication with lip seal fig Oil lubrication with labyrinth seal figReplacing the shaft protecting sleeve Removing a double-acting mechanical seal With the rules of sound engineering practice ReassemblyDismantling the hydraulic system Intermediate bearing bush Intermediate bearing diffuserSeals Gland packing Reassembly of hydraulic systemStuffing box housing Leakage at the mechanical seal Mechanical sealsHorizontal baseplate-mounted pump units Sealing elementsTightening the shaft nuts on Multitec pumps Rolling element bearing sizes Grease-lubricated bearings Fixed bearingMTC 100/125/150 Radial bearing Temperature of the rolling element bearingsRe-adjusting the clearance gaps Maximum clearance gaps Installation and returning to serviceMultitec Trouble-shooting Pump sizes 32 to General assembly drawingPump sizes 100, 125 Close-coupled pump up to pump sizeRadial suction nozzle Vertical design Pump sizes 32, 50Pump sizes 125 529 List of componentsDescription 525.1/2/4 Spacer sleeveBild Achtung AttenzionKSB Aktiengesellschaft

1777.8/7-10 G3 specifications

The Multitech 1777.8/7-10 G3 is a prominent device designed for the evolving landscape of communication technology. This multi-functional solution becomes essential for businesses and organizations that demand flexibility and reliability in their network infrastructure.

One of the main features of the Multitech 1777.8/7-10 G3 is its support for multiple communication interfaces. This device can handle several protocols, enabling seamless connectivity regardless of the environment. The built-in support for both voice and data services makes it an attractive solution for various applications, from remote offices to industrial settings.

In terms of technologies, the device stands out with its advanced modular design. Users can easily customize the device with different interface cards based on their specific communication needs. This adaptability ensures that organizations can scale their operations without needing to invest in entirely new hardware as their requirements change.

The Multitech 1777.8/7-10 G3 also emphasizes high security and reliability. It implements multiple security features, including encryption and authentication processes, safeguarding sensitive data transmission. These features are particularly important for organizations that must comply with strict regulatory requirements.

Another characteristic of the Multitech 1777.8/7-10 G3 is its robust performance under various operating conditions. The device is engineered for durability and can withstand significant environmental stresses, making it ideal for deployment in less than optimal locations.

Moreover, the integration of VoIP capabilities allows users to benefit from cost-effective voice communication solutions. This convergence of voice and data services streamlines operations and reduces overall costs while maintaining high-quality service.

The user-friendly interface of the Multitech 1777.8/7-10 G3 ensures that system administrators can easily configure and manage the device. comprehensive monitoring and reporting functions enable businesses to keep track of their network performance, ensuring that they can address any potential issues proactively.

To summarize, the Multitech 1777.8/7-10 G3 is a testament to modern communication technologies, combining flexibility, security, and ease of use while equipping businesses with the tools necessary for efficient operations in a rapidly changing digital landscape.