Mitsumi electronic PLA-A18AA, PLA-A30AA, PLA-A42AA, PLA-A36AA Outlines and Dimensions, Unit inchmm

Page 11

7

OUTLINES AND DIMENSIONS

INDOOR UNIT

PLA-A12AA PLA-A18AA PLA-A24AA PLA-A12AA1PLA-A18AA1PLA-A24AA1PLA-A30AA PLA-A36AA PLA-A42AA PLA-A30AA1PLA-A36AA1PLA-A42AA1

Unit : inch(mm)

Ceiling hole

25/32~1-25/32(20~45)33-27/32~35-13/16(860~910)

 

Fresh air intake

 

31-7/8(810)

 

6-1/4(159)Suspension bolt pitch

 

 

 

 

 

 

6-1/4(159)

 

 

 

 

 

 

1/16(840)-33

Branch duct hole

 

Terminal block

 

 

27/32(98)

 

 

 

 

 

9/16(192)

3-

 

 

 

 

 

 

C

D

 

 

 

 

 

7-

 

 

 

 

 

 

 

 

 

 

 

7-3/4(197)

 

 

 

Suspension bolt

 

33-1/16(840)

 

 

 

 

 

 

 

W3/8(M10)

 

 

Feeding hole

 

 

 

 

 

 

 

 

 

1

 

 

(Drain pump)

 

11/16(170)-6

1/2(140)-5

 

2-3/8(60)11-1/4(286)

14-23/32(374)

 

 

 

 

2-[1-1/16(27)

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

lower edge

(50~70) 31/32~2-1 -3/4

1-1/2(37)

Air intake grille

Air intake hole

 

 

 

 

 

1-3/4(45)

9-3/4(248)

 

Wiring entrance holes

22-23/32(577)

Suspension bolt

Branch duct hole

 

 

 

 

(20~45)

25/32-25/32~1

 

 

3-15/16(100)

 

3-15/16(100)(Cut out hole)

1/8(130)-5

 

 

 

 

 

 

3-17/32(90)

15/16(100)-3

 

 

 

 

 

 

 

 

3-17/32(90)

 

25/32~1-25/32(20~45)

 

 

 

 

 

 

 

1(26)

1/4(159)-6

 

13/16(605)-23

pitchboltSuspension

13/16(860~910)-27/32~35-33

holeCeiling

[6-7/8([175)

13-25/32(350)

 

 

 

 

 

14-[1/8([2.8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burring hole

 

 

 

 

 

 

 

Branch duct hole

 

[5-29/32([150)

 

 

 

 

 

 

 

 

 

Detail drawing of fresh air intake

 

 

 

 

 

 

 

 

 

3-[1/8([2.8)

 

 

 

 

 

 

 

 

 

 

 

Burring hole

 

 

 

6-1/4(159)

 

 

(20~45)

25/32-25/32~1

 

7/32(158)-6

[4-29/32([125)

 

[3-15/16([100)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Cut out hole)

 

 

 

 

 

 

 

 

 

 

 

Ceiling surface

 

Drain pipe

 

 

 

 

 

 

 

 

 

O.D.[1-1/4([32) connection

 

 

 

 

 

(VP-25)

 

 

 

 

 

 

 

 

 

 

4-1/8(105)

 

A

B

 

 

 

 

 

 

5/16(135)

 

 

 

 

 

 

 

 

 

 

 

5-

 

 

)

 

 

 

 

 

 

 

 

 

15/32(190)

+5

0

3/16(30)-1

 

 

 

 

 

 

 

Ceiling surface

+3/16

0

 

 

 

 

 

 

 

 

 

(17

 

 

 

 

 

 

 

 

Grille

 

 

 

 

 

 

 

 

 

 

 

 

7-

11/16

 

 

 

 

 

 

 

 

6-3/32(155) 6-9/16(167)

)

+5

0

(17

+3/16

0

11/16

M

Drain hole

M

Auto vane

37-3/8(950)

16-3/16(411)

Air outlet hole

 

22-23/32(577) Air intake hole

 

-1/32(77)

M

 

 

 

 

M

Vane motor

 

3

 

 

 

 

2(51)

16-3/16(411)

 

2(51)

 

 

 

 

Air outlet hole

 

3-1/32(77)

 

 

37-3/8(950)

 

 

High efficiency filter

& Fresh air intake casement(option)

Unit : inch(mm)

Models

A

 

B

C

 

D

PLA-A12/18/24/30AA(1)

9-1/2

10-3/16

 

 

 

(241)

(258)

 

3-5/32

 

 

PLA-A36AA(1)

 

 

 

3-1/2

(80)

11-1/16 11-3/4

(89)

 

 

 

 

 

 

 

 

 

PLA-A42AA(1)

(281)

 

(298)

 

3-5/16

 

 

 

 

(84)

 

 

 

 

 

 

 

 

 

MODEL

12/18

24/30/36/42

 

1 Liquid pipe

1/4F

 

3/8F

 

 

2Gas pipe

1/2F

5/8F

11

Image 11
Contents Revised EDITION-B ContentsPLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA Technical Data BookTechnical Changes Reference ManualAlways Observe for Safety Safety PrecautionAdditional refrigerant charge Indoor Unit Part Names and FunctionsDisplay Section Wireless remote controller PLA-A24AA/ PLA-A24AA1Single phase,60Hz, 208/230V Specifications Service Ref PLA-A42AA/ PLA-A42AA1Single phase,60Hz, 208/230V PLA-A30AA/ PLA-A30AA1Single phase,60Hz, 208/230VPLA-A36AA/ PLA-A36AA1Single phase,60Hz, 208/230V PLA-A36AA Noise Criterion CurvesPLA-A12AA PLA-A12AA1Unit inchmm Outlines and DimensionsPlease set the voltage using Wiring DiagramHeat exchanger Refrigerant System DiagramTroubleshooting TroubleshootingCase of trouble during operation MALFUNCTION-DIAGNOSIS Method by Remote ControllerOutput pattern B Only A-CONTROL Please Wait SELF-DIAGNOSIS Action Table Working Pipe temperatureCause Countermeasure Freezing/overheating protection is ErrorE3/signal receiving errorE5 Cause Countermeasure Pipe temperature thermistorRemote controller transmission ErrorE0/signal receiving errorE4Indoor controller board Error Signal receiving errorError Transmitting error Remote controller control boardPly system Troubleshooting by Inferior PhenomenaPhenomena Cause Countermeasure Is offPerformance failure 4Receiver for wireless remoteIs blinking 3Upward/downward vaneEmergency Operation Fan motor MF Thermistor for lower temperature Test Point Diagram Indoor controller board SW2 Functions of DIP Switch and Jumper WireOperating Procedure Photos & Illustrations Disassembly ProcedureRemoving the fan motor Removing the drain pump and drain sensor Qty Wiring RecomPLA-A·AA Functional and Structural Parts PLA-A36AA98 PLA-A42AA Mended 12, 18, 24 Symbol Qty556 Functional and Structural Parts PLA-A36AA PLA-A42AA30/36/42AA1 RoHS Parts ListPLA-A18AA1 PLA-A24AA1PLA-A30AA1 WiringSymbol Qty Functional and Structural PartsPLA-A36AA198 RoHS Parts No Parts Name Remarks Functional and Structural Parts PLA-A36AA1 PLA-A42AA1Page Made in Japan