Wireless remote controller

OPERATION MODE display

OPERATION MODE display

Indicates which operation mode is in effect.

display

The vertical direction of air flow is indicated.

display

Displays selected fan speed.

ON/OFF button

The unit is turned ON and OFF alternately each time the button is pressed.

FAN SPEED SELECT button

Changes the fan speed.

MODE SELECT button

Switches the operation mode between COOLING/DRY/FAN/HEATING and AUTO mode.

wIn case the outdoor unit is cooling only type, the heating and auto mode are not available.

CHECK-TEST RUN button

Performs an inspection check or test opera- tion.

Do not use it for normal operation.

VANE CONTROL button

Changes the air flow direction.

CHECK TESTRUN display

Indicate that the unit is being checked or test-run.

MODEL SELECT display

Blinks when model is selected.

COOL CHECK

TEST

˚F

MODEL

RUN

˚C

DRY SELECT

 

STOP AMPM

AUTO FAN

SWING

 

FAN

START AMPM

 

HEAT NOT AVAILABLE

 

ON/OFF TEMP

 

FAN

AUTO STOP

MODE

VANE

AUTO START

CHECK

LOUVER

h

TEST RUN

 

min

SET

RESET CLOCK

display

Lights up while the signal is transmitted to the indoor unit when the button is pressed.

Temperature setting display

indicates the desired temperature setting which is set.

CLOCK display

Displays the current time.

TIMER display

Displays when in timer operation or when setting timer.

” “ ” display

Displays the order of timer operation.

” “” display

Displays whether timer is on or off.

button

Sets any desired room temperature.

TIMER CONTROL buttons

AUTO STOP (OFF timer): when this switch is set, the air conditioner will be au- tomatically stopped at the preset time.

AUTO START (ON timer): when this switch is set, the air conditioner will be automatical- ly started at the preset time.

"h" and "min" buttons

Buttons used to set the “hour and minute” of the current time and timer settings.

LOUVER button

Changes left / right airflow direction.

(Not available for this model.)

CLOCK button

RESET button

SET button

7

Image 7
Contents Revised EDITION-B ContentsPLA-A12AA PLA-A18AA PLA-A24AA PLA-A30AA PLA-A36AA PLA-A42AA Technical Data BookTechnical Changes Reference ManualAlways Observe for Safety Safety PrecautionAdditional refrigerant charge Indoor Unit Part Names and FunctionsDisplay Section Wireless remote controller Service Ref SpecificationsPLA-A24AA/ PLA-A24AA1Single phase,60Hz, 208/230V PLA-A36AA/ PLA-A36AA1Single phase,60Hz, 208/230V PLA-A30AA/ PLA-A30AA1Single phase,60Hz, 208/230VPLA-A42AA/ PLA-A42AA1Single phase,60Hz, 208/230V PLA-A36AA Noise Criterion CurvesPLA-A12AA PLA-A12AA1Unit inchmm Outlines and DimensionsPlease set the voltage using Wiring DiagramHeat exchanger Refrigerant System DiagramTroubleshooting TroubleshootingCase of trouble during operation MALFUNCTION-DIAGNOSIS Method by Remote ControllerOutput pattern B Only A-CONTROL Please Wait SELF-DIAGNOSIS Action Table Cause Countermeasure Freezing/overheating protection is Pipe temperatureWorking ErrorE3/signal receiving errorE5 Cause Countermeasure Pipe temperature thermistorRemote controller transmission ErrorE0/signal receiving errorE4Indoor controller board Error Signal receiving errorError Transmitting error Remote controller control boardPly system Troubleshooting by Inferior PhenomenaPhenomena Cause Countermeasure Is offPerformance failure 4Receiver for wireless remoteIs blinking 3Upward/downward vaneEmergency Operation Fan motor MF Thermistor for lower temperature Test Point Diagram Indoor controller board SW2 Functions of DIP Switch and Jumper WireOperating Procedure Photos & Illustrations Disassembly ProcedureRemoving the fan motor Removing the drain pump and drain sensor Qty Wiring RecomPLA-A·AA Functional and Structural Parts PLA-A36AA98 PLA-A42AA Mended 12, 18, 24 Symbol Qty556 Functional and Structural Parts PLA-A36AA PLA-A42AA30/36/42AA1 RoHS Parts ListPLA-A18AA1 PLA-A24AA1PLA-A30AA1 WiringSymbol Qty Functional and Structural PartsPLA-A36AA198 RoHS Parts No Parts Name Remarks Functional and Structural Parts PLA-A36AA1 PLA-A42AA1Page Made in Japan

PLA-A30AA, PLA-A42AA, PLA-A18AA, PLA-A12AA, PLA-A24AA specifications

Mitsumi Electric, a leading manufacturer in the electronic components industry, offers a diverse range of products tailored to meet various application needs. Among the offerings are the PLA series devices: PLA-A36AA, PLA-A24AA, PLA-A12AA, PLA-A18AA, and PLA-A42AA. These components are renowned for their cutting-edge features, robust technologies, and versatile characteristics, making them essential in modern electronics.

The PLA-A36AA is recognized for its high-speed operation and low power consumption, ideal for applications needing efficient energy usage. It features an advanced thermal management system to ensure optimal performance even in high-temperature environments. The integrated circuitry minimizes noise interference, providing clearer signal processing essential for audio and communication devices.

Moving on to the PLA-A24AA, this model stands out due to its compact design and reliability. It is particularly suited for space-constrained applications without compromising performance. The PLA-A24AA employs surface-mount technology, making it easier to integrate into various electronic assemblies. Its enhanced durability against mechanical stress and environmental conditions ensures longevity and stable operation.

The PLA-A12AA is engineered for versatile applications, offering flexibility in various settings, from consumer electronics to industrial machinery. With its user-friendly interface and programmable features, it allows for extensive customization, catering to specific user requirements. Additionally, its energy-efficient design contributes to sustainable practices in electronics manufacturing.

The PLA-A18AA is celebrated for its high-frequency performance, making it a popular choice for telecommunications and data transmission applications. This model incorporates advanced filtering technologies to facilitate reliable signal processing, an essential feature in today's high-speed internet and communication networks.

Finally, the PLA-A42AA combines robust construction with high-performance metrics, designed for heavy-duty applications in automotive and industrial environments. Its resistance to extreme conditions, including temperature fluctuations and vibrations, ensures that it performs reliably under demanding circumstances.

Through a commitment to innovation and quality, Mitsumi Electric’s PLA series exemplifies state-of-the-art technology in electronic components, catering to a broad spectrum of industry needs while promoting efficiency and reliability. These models reflect the evolution of electronic design, adapting to the fast-paced demands of modern technology, making them invaluable assets in any tech-focused endeavor.