5.4USER OPTIONS

Options [1] and [2]: Master Feature

When option [1] is OFF, the User cannot program other Users into the system.

When option [1] is ON and option [2] is OFF, the User can only modify existing User Access Codes.

When both options [1] and [2] are ON, the User has Full Master rights. The User can create or modify User Access Codes, User Options, User Access Control Options, Access Card Numbers and Area Assignments according to their own programming. For example, if the Full Master User has access to area #1 and option [4] (Bypass) only, the Full Master User can only assign area #1 and option [4] to other Users in the system.

Option [3]: Duress

When option [3] is ON, the Duress feature is enabled. This feature is used when someone forces a User to arm or disarm an area(s). By entering a User Access Code (P.I.N.) reserved for the Duress feature, the system will arm or disarm the area(s), and then send a silent alarm to the Central Monitoring Station.

Option [4]: Bypass

When option [4] is ON, the Bypass feature is enabled. This feature allows the User to deactivate zones when arming the area(s).

Option [5]: Arm Only

When option [5] is ON, the Arm Only feature is enabled. The User can arm assigned areas with either a card or code, but cannot disarm. When the option is OFF, the User can either arm or disarm assigned areas.

Option [6]: Stay & Instant Arm

When option [6] is ON, the Stay and Instant Arm features are enabled. The User can now Stay or Instant Arm their assigned areas.

Option [7]: Force Arm

When option [7] is ON, the Force arm feature is enabled. The User can now Force arm their assigned areas.

Option [8]: Area Access

When option [8] is ON, the keypad will permit access to all the areas assigned to the User Access Code. When option [8] is OFF, the keypad will only permit access to the areas it controls. For example, the keypad is assigned area 1 only, and your User Access Code is assigned areas 1 to 4. If the option is ON, you can access all four areas from the keypad. If the option is OFF, you can only access area 1.

By default all Users can Regular arm the system.

5.5ACCESS CONTROL USER OPTIONS

Option [1]: Access Card is Activated

When option [1] is ON, the Access Control Card is activated and can be used when Access Control is enabled in the system. When the option is OFF, the Access Control Card cannot be used.

Option [2]: Disarming with Access Card

When option [2] is ON, a User’s Access Control Card can unlock and disarm an armed Access Control Door (see section 6.2.2 on page 12).

For option [2] to function in the ON position, option [5] “Arm Only” in the User Options must be disabled (refer to section 5.4 on page 11).

Option [3]: Card with Extended Unlocked Period

When option [3] is ON, “Extended Unlocked Period” is enabled. “Extended Unlocked Period” refers to the time period programmed into each Access Control Door by your Installer that extends the unlocked time of the door. For example, if your Installer sets the Unlocked period of the door to 30 seconds and the Extended Unlocked Period to 15 seconds, then a User Access Code with “Extended Unlocked Period” enabled will have a total of 45 seconds to pass through the door.

Options [4] to [7]: Arming with Card

Options [4] to [7] define the type of arming when arming with an Access Control Card (refer to section 6.2.1 on page 12). You can either Regular arm, Stay arm, Instant arm, or Force arm.

[4]ON, [5] to [7] OFF = Regular Arm

[4]& [5] ON, [6] & [7] OFF = Stay Arm

[4]& [6] ON, [5] & [7] OFF = Instant Arm

[4]& [7] ON, [5] & [6] OFF = Force Arm

LCD Keypad 11

Image 11
Contents System Manager’s Manual For DGP-848 Systems Page Table of Contents Auditory Feedback Beep Tones IntroductionBasic Operation Arming Bypass Programming Stay ArmingInstant Arming Force ArmingDisarming Programming User Access Codes Access Codes Alarm Memory Display Deleting User Access CodesProgramming User Access Codes System Manager’s Manual User Options Access Control User OptionsArming and Disarming with Card Using Access ControlEntering & Exiting Example a HOW Access Control WorksEvent Record Display Trouble DisplaySET Time & Date Additional FeaturesKeypad Settings Programmable Outputs PgmsTesting and Maintenance Standard Fire Zone Fire and Burglar AlarmsDelayed Fire Zone System TestHome Fire Warning System Fire Safety TipsBurglar Alarm Minimizing Home Fire HazardsHOW do I USE IT? When Accessing Your IntouchWhen Arming or Disarming When Activating or Deactivating a PGMIntouch Example Telephone Button FeaturesWhen Using Your Intouch Intouch System Checklist Warranty Index Area Access, in User Options Area Status DisplayUser Access Codes Page Page