06Accessory selection
Multipoint 75/100 ACCESSORIES
Thermostatic blending valves
Pack U3 and U7 for use with all Multipoints;
Thermostatic blending valves allow water to be stored at high temperatures and blended with cold water to a preset outlet temperature. This provides
system capacities.
PACK U3 TMV2
Connection 15mm compression.
Allows water to be safely stored above 60°C
Precisely controls outlet water temperature (range 35°C to 60°C)
Lockable control knob
Incorporates check valves to prevent cross contamination
Operating pressure 0.2 bar to 6.0 bar
PACK U7 TMV3
Connection 15mm compression.
Fully approved under the TMV3 scheme to the DO8 specification
Allows water to be safely stored above 60°C
Precisely controls outlet water temperature (range 38°C to 46°C)
Unique adjuster key to prevent unauthorised temperature adjustment
Incorporates check valves to prevent cross contamination
Operating pressure 0.2 bar to 5.0 bar
TMV Installation
Heater |
Outlet taps | Hot outlet | Cold water in |
|
Blended water | Pack U3 or U7 |
to outlets | blending valve |
Balanced cold water supply
Technical Support
Heatrae Sadia offers a dedicated Specifier Advice line to provide information and advice on specification and installation. This is supported by a
Water expands by up to 4% when heated (See Fig. 1). This means that the design of the water heater and the installation in which it is used are critical. Conventional (vented) and unvented systems allow for expansion in different ways.
FIG. 1 |
|
|
|
|
|
|
|
|
| |
| 4.34 |
|
|
|
|
|
|
|
|
|
| 4 |
|
|
|
|
|
|
|
|
|
% | 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
S I O N | 2 |
|
|
|
|
|
|
|
|
|
X P A N | 1.2 |
|
|
|
|
|
|
|
|
|
E |
|
|
|
|
|
|
|
|
| |
1 |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| |
| 0 |
|
|
|
|
|
|
|
|
|
| 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 100 |
| T E M P E R A T U R E R I S E |
| O C |
|
|
With unvented systems, there are no cistern tanks or open outlets to accommodate expansion. All systems above 15 litre, and some systems of 15 litre or less, employ an expansion vessel or an internal
With larger systems (above 15 litre), expansion is accommodated either by a separate expansion vessel or an internal
Building Regulations
Direct connection to the cold mains supply has been permitted in the UK since 1987. All units above 15 litre must be installed to meet the requirements of the Building Regulations. It is a legal requirement that the local Building Control Officer be notified of any proposed installation of unvented water heating systems over 15 litre capacity. Products up to 500 litre and 45kW must be approved by a recognised body such as the British Board of Agrément (BBA) and BEAB and be fitted by an installer who has successfully completed a recognised course in the installation of unvented heating systems such as CITB.
Requirements call for an expansion space (internal or external), safety devices to prevent the stored water exceeding 99°C, and pipework to convey discharged hot water safely away from the safety devices.